A System for the Measurement of the Subjective Visual Vertical using a Virtual Reality Device

被引:15
|
作者
Negrillo-Cardenas, Jose [1 ]
Rueda-Ruiz, Antonio J. [1 ]
Ogayar-Anguita, Carlos J. [1 ]
Lomas-Vega, Rafael [2 ]
Segura-Sanchez, Rafael J. [1 ]
机构
[1] Univ Jaen, Dept Comp Sci, Campus Las Lagunillas S-N,A3 Bldg, Jaen 23071, Spain
[2] Univ Jaen, Dept Hlth Sci, Jaen, Spain
关键词
Subjective visual vertical (SVV); Diagnostic tool; Rehabilitation; Virtual reality; Mobile application; PAROXYSMAL POSITIONAL VERTIGO; VESTIBULAR FUNCTION; MULTIPLE-SCLEROSIS; PERCEPTION; STROKE; REHABILITATION; QUESTIONNAIRES; RELIABILITY; DISEASE;
D O I
10.1007/s10916-018-0981-y
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The Subjective Visual Vertical (SVV) is a common test for evaluating the perception of verticality. Altered verticality has been connected with disorders in the otolithic, visual or proprioceptive systems, caused by stroke, Parkinson's disease or multiple sclerosis, among others. Currently, this test is carried out using a variety of specific, mostly homemade apparatuses that include moving planes, buckets, hemispheric domes or a line projected in a screen. Our aim is to develop a flexible, inexpensive, user-friendly and easily extensible system based on virtual reality for the measurement of the SVV and several related visual diagnostic tests, and validate it through an experimental evaluation. Two different hardware configurations were tested with 50 healthy volunteers in a controlled environment; 28 of them were males and 22 females, with ages ranging from 18 to 49 years, being 23 the average age. The Intraclass Correlation Coefficient (ICC) was computed in each device. In addition, a usability survey was conducted. ICC = 0.85 in the first configuration (CI = 0.75-0.92), ICC = 0.76 in the second configuration (CI = 0.61-0.87), both with 95% of confidence, which means a substantial reliability. Moreover, 92.2% of subjects rated the usability of the system as "very good". Our evaluation showed that the proposed system is suitable for the measurement of SVV in healthy subjects. The next step is to perform a more elaborated experimentation on patients and compare the results with the measurements obtained from traditional methods.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Feasibility and System Architecture for Vision Field Measurement Using Virtual Reality Technology
    Manninen, Eemeli
    Valve, Henrik
    Amarakoon, Sankha
    Dahanayake, Ajantha
    INFORMATION MODELLING AND KNOWLEDGE BASES XXX, 2019, 312 : 539 - 548
  • [42] RETRACTED: Subjective visual vertical in virtual reality (Curator SVV): validation and normative data (Retracted article. See OCT, 2022)
    Chiarovano, Elodie
    McGarvie, Leigh A.
    Szmulewicz, David
    MacDougall, Hamish G.
    VIRTUAL REALITY, 2018, 22 (04) : 315 - 320
  • [43] Remote manipulation of guidewire using a virtual reality device
    Fukasaku, K
    Negoro, M
    Himeno, R
    INTERVENTIONAL NEURORADIOLOGY, 2001, 7 : 29 - 34
  • [44] Feasibility of a walking virtual reality system for rehabilitation: objective and subjective parameters
    Borrego, Adrin
    Latorre, Jorge
    Llorens, Roberto
    Alcaniz, Mariano
    Noe, Enrique
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2016, 13
  • [45] Feasibility of a walking virtual reality system for rehabilitation: objective and subjective parameters
    Adrián Borrego
    Jorge Latorre
    Roberto Llorens
    Mariano Alcañiz
    Enrique Noé
    Journal of NeuroEngineering and Rehabilitation, 13
  • [46] Assessment of otolith function by using subjective visual vertical analysis
    Bohmer, A
    HNO, 1997, 45 (07) : 533 - 537
  • [47] Using virtual reality to study visual performances of honeybees
    Schultheiss, Patrick
    Buatois, Alexis
    Avargues-Weber, Aurore
    Giurfa, Martin
    CURRENT OPINION IN INSECT SCIENCE, 2017, 24 : 43 - 50
  • [48] Position measurement system for virtual reality and mobile multimedia
    Haapasaari, M
    Ruotsalainen, J
    Salmimaa, M
    Palovuori, K
    Vanhala, J
    PROCEEDINGS OF THE ICMA'98 - ADVANCED MECHATRONICS: FIRST-TIME-RIGHT, VOLS 1 AND 2, 1998, : 557 - 568
  • [49] Usability of a Portable Virtual Reality Device for Visual Field Screening in Outreach Settings
    Gregerson, Celestine
    Annis, Trevor
    Murri, Michael
    Shumway, Caleb
    Pettey, Jeff H.
    Shah, Avni
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [50] Validation of a Head-mounted Virtual Reality Visual Field Screening Device
    Mees, Lukas
    Upadhyaya, Swati
    Kumar, Pavan
    Kotawala, Sandal
    Haran, Shankar
    Rajasekar, Shruthi
    Friedman, David S.
    Venkatesh, Rengaraj
    JOURNAL OF GLAUCOMA, 2020, 29 (02) : 86 - 91