New laser speckle flowgraphy system using CCD camera

被引:79
|
作者
Konishi, N [1 ]
Tokimoto, Y [1 ]
Kohra, K [1 ]
Fujii, H [1 ]
机构
[1] Kyushu Inst Technol, Dept Comp Sci & Elect, Iizuka, Fukuoka 8208502, Japan
关键词
laser speckles; blood flowmetry; flow visualization; medical instruments;
D O I
10.1007/s10043-002-0163-4
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new technique is developed to visualize the blood flow map of the human retina using laser speckle phenomena. Despite use of an ordinary CCD camera as the detector. the performance of laser speckle flowgraphy system for the analysis of ocular blood circulation is greatly improved to achieve higher resolution and a wider field of view for blood flow mapping. It is shown that the quality of the blood flow map is influenced by the sampling format of the pixel points in the space- and time-varying speckle field.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 50 条
  • [31] Measurements of Retinal Perfusion Using Laser Speckle Flowgraphy and Doppler Optical Coherence Tomography
    Luft, Nikolaus
    Wozniak, Piotr A.
    Aschinger, Gerold C.
    Fondi, Klemens
    Bata, Ahmed M.
    Werkmeister, Rene M.
    Schmidl, Doreen
    Witkowska, Katarzyna J.
    Bolz, Matthias
    Garhoefer, Gerhard
    Schmetterer, Leopold
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (13) : 5417 - 5425
  • [32] Cerebral Circulation During Retrograde Cerebral Perfusion: Evaluation Using Laser Speckle Flowgraphy
    Kanda, Hirotsugu
    Kunisawa, Takayuki
    Iida, Takafumi
    Tada, Masahiro
    Kimura, Fumiaki
    Ise, Hayato
    Kamiya, Hiroyuki
    ANNALS OF THORACIC SURGERY, 2019, 107 (06): : 1747 - +
  • [33] Blood flow analyses of skin tissue under the Sacrum using laser speckle flowgraphy
    Lee, MC
    Konishi, N
    Fujii, H
    OPTICAL REVIEW, 2003, 10 (06) : 562 - 566
  • [34] A New Approach to Retinal Oxygen Extraction Measurement Based on Laser Speckle Flowgraphy and Retinal Oximetry
    Pai, Viktoria
    Janku, Patrick
    Lindner, Theresa
    Graf, Ulrich
    Schmetterer, Leopold
    Garhoefer, Gerhard
    Schmidl, Doreen
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (12):
  • [35] Straightness Measurement Using Laser Diode and CCD Camera
    HAO Qun ZHAO Yang LI Dacheng CAO Mang (State Key Laboratory of Precision Measurement Technology and Instrument
    ChineseJournalofLasers, 1999, (03) : 24 - 29
  • [36] Use of laser speckle flowgraphy in ocular blood flow research
    Sugiyama, Tetsuya
    Araie, Makoto
    Riva, Charles E.
    Schmetterer, Leopold
    Orgul, Selim
    ACTA OPHTHALMOLOGICA, 2010, 88 (07) : 723 - 729
  • [37] Two-wavelength microscopic speckle interferometry using colour CCD camera
    Upputuri, Paul Kumar
    Pramanik, Manojit
    Kothiyal, Mahendra Prasad
    Nandigana, Krishna Mohan
    INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS 2014, 2015, 9302
  • [38] Measuring hyperemic response to light flicker stimulus using continuous laser speckle flowgraphy in mice
    Tamplin, Michelle R.
    Broadhurst, Kimberly A.
    Vitale, Anthony H.
    Hashimoto, Ryuya
    Kardon, Randy H.
    Grumbach, Isabella M.
    EXPERIMENTAL EYE RESEARCH, 2022, 216
  • [40] Longitudinal changes of ocular blood flow using laser speckle flowgraphy during normal pregnancy
    Sato, Takahiro
    Sugawara, Junichi
    Aizawa, Naoko
    Iwama, Noriyuki
    Takahashi, Fumiaki
    Nakamura-Kurakata, Michiyo
    Saito, Masatoshi
    Sugiyama, Takashi
    Kunikata, Hiroshi
    Nakazawa, Toru
    Yaegashi, Nobuo
    PLOS ONE, 2017, 12 (03):