Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation

被引:637
|
作者
Brook, AD [1 ]
Ahrens, TS
Schaiff, R
Prentice, D
Sherman, G
Shannon, W
Kollef, MH
机构
[1] Washington Univ, Sch Med, Dept Internal Med, Div Pulm & Crit Care Med, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Internal Med, Div Gen Med Sci & Biostat, St Louis, MO 63110 USA
[3] Barnes Jewish Hosp, Dept Nursing, St Louis, MO 63110 USA
[4] Barnes Jewish Hosp, Dept Pharm, St Louis, MO 63110 USA
关键词
sedation; mechanical ventilation; critical care; outcomes; intensive care unit; tracheostomy;
D O I
10.1097/00003246-199912000-00001
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare a practice of protocol-directed sedation during mechanical ventilation implemented by nurses with traditional non-protocol-directed sedation administration. Design: Randomized, controlled clinical trial. Setting: Medical intensive care unit (19 beds) in an urban teaching hospital. Patients: Patients requiring mechanical ventilation (n = 321). Interventions: Patients were randomly assigned to receive either protocol-directed sedation (n = 162) or non-protocol-directed sedation (n = 159). Measurements and Main Results: The median duration of mechanical ventilation was 55.9 hrs (95% confidence interval, 41.0-90.0 hrs) for patients managed with protocol-directed sedation and 117.0 hrs (95% confidence interval, 96.0-155.6 hrs) for patients receiving non-protocol-directed sedation. Kaplan-Meier analysis demonstrated that patients in the protocol-directed sedation group had statistically shorter durations of mechanical ventilation than patients in the non-protocol-directed sedation group (chi-square = 7.00, p = .008, log rank test; chi-square = 8.54, p = .004, Wilcoxon's test; chi-square = 9.18, p = .003, -2 log test). Lengths of stay in the intensive care unit (5.7 +/- 5.9 days vs, 7.5 +/- 6.5 days; p = .013) and hospital (14.0 +/- 17.3 days vs. 19.9 +/- 24.2 days; p < .001) were also significantly shorter among patients in the protocol-directed sedation group. Among the 132 patients (41.1%) receiving continuous intravenous sedation, those in the protocol-directed sedation group (n = 66) had a significantly shorter duration of continuous intravenous sedation than those in the non-protocol-directed sedation group (n = 66) (3.5 +/- 4.0 days vs, 5.6 +/- 6.4 days; p = .003). Patients in the protocol-directed sedation group also had a significantly lower tracheostomy rate compared with patients in the non-protocol-directed sedation group (10 of 162 patients [6.2%] vs, 21 of 159 patients [13.2%], p = .038). Conclusions: The use of protocol-directed sedation can reduce the duration of mechanical ventilation, the intensive care unit and hospital lengths of stay, and the need far tracheostomy among critically ill patients with acute respiratory failure.
引用
收藏
页码:2609 / 2615
页数:7
相关论文
共 50 条
  • [31] Effects of increasing compliance with minimal sedation on duration of mechanical ventilation: a quality improvement intervention
    Andre CKB Amaral
    Lars Kure
    Angie Jeffs
    [J]. Critical Care, 16
  • [32] Effects of increasing compliance with minimal sedation on duration of mechanical ventilation: a quality improvement intervention
    Amaral, Andre C. K. B.
    Kure, Lars
    Jeffs, Angie
    [J]. CRITICAL CARE, 2012, 16 (03):
  • [33] DURATION OF MECHANICAL VENTILATION WITH NON-BENZODIAZEPINE VERSUS BENZODIAZEPINE-BASED SEDATION
    Franco, Elizabeth
    Mak, Garbo
    Cortes, Jennifer
    [J]. CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [34] Duration of mechanical ventilation
    Merrill, WW
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (22): : 1611 - 1611
  • [35] Outcomes in post-ICU mechanical ventilation - A therapist-implemented weaning protocol
    Scheinhorn, DJ
    Chao, DC
    Stearn-Hassenpflug, M
    Wallace, WA
    [J]. CHEST, 2001, 119 (01) : 236 - 242
  • [36] Sedation protocols do not reduce ventilation duration
    Curley, M. A. Q.
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 2016, 175 (11) : 1414 - 1415
  • [37] Nursing care protocol for critical users with tracheostomy under mechanical ventilation
    Lima, Fernando Conceicao de
    Neves, Wagner Felipe dos Santos
    Dias, Andre Lucas de Lima
    Mendes, Clarissa Porfirio
    Simor, Alzinei
    Pimentel, Ingrid Magali de Souza
    Sonobe, Helena Megumi
    Santana, Mary Elizabeth de
    [J]. REVISTA BRASILEIRA DE ENFERMAGEM, 2024, 77 (02)
  • [38] Effect of Neuromuscular Electrical Stimulation on the Duration of Mechanical Ventilation
    Gutierrez-Arias, Ruvistay E.
    Zapata-Quiroz, Constanza C.
    Prenafeta-Pedemonte, Benjamin O.
    Nasar-Lillo, Nicolas A.
    Gallardo-Zamorano, Diego, I
    [J]. RESPIRATORY CARE, 2021, 66 (04) : 679 - 685
  • [39] Effect of a nurse-implemented sedation protocol on the incidence of ventilator-associated pneumonia
    Quenot, Jean-Pierre
    Ladoire, Sylvain
    Devoucoux, Fabrice
    Doise, Jean-Marc
    Cailliod, Romain
    Cunin, Nicole
    Aube, Herve
    Bleftery, Bernard
    Charles, Pierre Emmanuel
    [J]. CRITICAL CARE MEDICINE, 2007, 35 (09) : 2031 - 2036
  • [40] FEASIBILITY OF A NOVEL SEDATION INTERRUPTION PROTOCOL (CYCLING) IN PEDIATRIC PATIENTS DURING MECHANICAL VENTILATION
    Gelvez, Javier
    Thompson, Linda
    [J]. CRITICAL CARE MEDICINE, 2012, 40 (12) : U301 - U301