Acoustic response of compliable microvessels containing ultrasound contrast agents

被引:119
|
作者
Qin, Shengping [1 ]
Ferrara, Katherine W. [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 20期
关键词
D O I
10.1088/0031-9155/51/20/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The existing models of the dynamics of ultrasound contrast agents (UCAs) have largely been focused on an UCA surrounded by an infinite liquid. Preliminary investigations of a microbubble's oscillation in a rigid tube have been performed using linear perturbation, under the assumption that the tube diameter is significantly larger than the UCA diameter. In the potential application of drug and gene delivery, it may be desirable to fragment the agent shell within small blood vessels and in some cases to rupture the vessel wall, releasing drugs and genes at the site. The effect of a compliant small blood vessel on the UCA's oscillation and the microvessel's acoustic response are unknown. The aim of this work is to propose a lumped-parameter model to study the interaction of a microbubble oscillation and compliable microvessels. Numerical results demonstrate that in the presence of UCAs, the transmural pressure through the blood vessel substantially increases and thus the vascular permeability is predicted to be enhanced. For a microbubble within an 8 to 40 mu m vessel with a peak negative pressure of 0.1 MPa and a centre frequency of 1 MHz, small changes in the microbubble oscillation frequency and maximum diameter are observed. When the ultrasound pressure increases, strong nonlinear oscillation occurs, with an increased circumferential stress on the vessel. For a compliable vessel with a diameter equal to or greater than 8 mu m, 0.2 MPa PNP at 1 MHz is predicted to be sufficient for microbubble fragmentation regardless of the vessel diameter; however, for a rigid vessel 0.5 MPa PNP at 1 MHz may not be sufficient to fragment the bubbles. For a centre frequency of 1 MHz, a peak negative pressure of 0.5 MPa is predicted to be sufficient to exceed the stress threshold for vascular rupture in a small (diameter less than 15 mu m) compliant vessel. As the vessel or surrounding tissue becomes more rigid, the UCA oscillation and vessel dilation decrease; however the circumferential stress is predicted to increase. Decreasing the vessel size or the centre frequency increases the circumferential stress. For the two frequencies considered in this work, the circumferential stress does not scale as the inverse of the square root of the acoustic frequency nu(a) as in the mechanical index, but rather has a stronger frequency dependence, 1/nu(a).
引用
收藏
页码:5065 / 5088
页数:24
相关论文
共 50 条
  • [41] CONTRAST AGENTS IN DIAGNOSTIC ULTRASOUND
    OPHIR, J
    PARKER, KJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (04): : 319 - 333
  • [42] Improvements in ultrasound contrast agents
    deJong, N
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06): : 72 - 82
  • [43] Imaging ultrasound contrast agents
    Bruce, M
    MEDICAL PHYSICS, 2005, 32 (06) : 2151 - 2152
  • [44] Ultrasound contrast agents for echocardiography
    Yasu, T
    Schmid-Schönbein, GW
    DRUGS OF TODAY, 2000, 36 (10) : 725 - 731
  • [45] Modeling of ultrasound contrast agents
    Frinking, PJA
    de Jong, N
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 1601 - 1604
  • [46] ULTRASOUND CONTRAST AGENTS - DISCUSSION
    DAWSON, P
    JANOFF, AS
    SCHLIEF, R
    DEHAEN, C
    GRABOWSKI
    WOLF, GL
    MORRIS, TW
    MATTREY, RF
    LIPTON, MJ
    WIDDER
    HOLTZ
    LASSER, EC
    FLAIM, SF
    SCHNEIDER
    SCHLIEF, R
    VIOLANTE, MR
    HARNISH
    PARVEZ
    BARNHART, JL
    FRITZZIEROTH, B
    INVESTIGATIVE RADIOLOGY, 1991, 26 : S198 - S200
  • [47] Contrast agents for endoscopic ultrasound
    Bhutani, MS
    GASTROINTESTINAL ENDOSCOPY, 1998, 47 (03) : 324 - 324
  • [48] Ultrasound contrast agents applications
    Vicenzini, E.
    CEREBROVASCULAR DISEASES, 2015, 39 : 3 - 3
  • [49] CONTRAST AGENTS FOR DIAGNOSTIC ULTRASOUND
    ZISKIN, MC
    BONAKDARPOUR, A
    WEINSTEIN, DP
    LYNCH, PR
    INVESTIGATIVE RADIOLOGY, 1972, 7 (06) : 500 - 505
  • [50] Safety of ultrasound contrast agents
    Jakobsen, JÅ
    Oyen, R
    Thomsen, HS
    Morcos, SK
    EUROPEAN RADIOLOGY, 2005, 15 (05) : 941 - 945