Dose equivalent measurements in a strongly pulsed high-energy radiation field

被引:9
|
作者
Mayer, S [1 ]
Golnik, N
Kyllönen, JE
Menzel, HG
Otto, T
机构
[1] CERN, CH-1211 Geneva 23, Switzerland
[2] Warsaw Univ Technol, Inst Precis & Biomed Engn, PL-02525 Warsaw, Poland
关键词
D O I
10.1093/rpd/nch177
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The stray radiation field outside the shielding of high-energy accelerators comprises neutrons, photons and charged particles with a wide range of energies. Often, accelerators operate by accelerating and ejecting short pulses of particles, creating an analogue, pulsed radiation field. The pulses can be as short as 10 mus with high instantaneous fluence rates and dose rates. Measurements of average dose equivalent (rate) for radiation protection purposes in these fields present a challenge for instrumentation. The performance of three instruments (i.e. a recombination chamber, the Sievert Instrument and a HANDI-TEPC) measuring total dose equivalent is compared in a high-energy reference radiation field (CERF) and a strongly pulsed, high-energy radiation field at the CERN proton synchrotron (PS).
引用
收藏
页码:759 / 762
页数:4
相关论文
共 50 条
  • [31] BIOPHYSICAL STUDIES WITH HIGH-ENERGY ARGON IONS .1. DEPTH DOSE MEASUREMENTS IN TISSUE-EQUIVALENT LIQUID AND IN WATER
    GOODMAN, LJ
    COLVETT, RD
    RADIATION RESEARCH, 1977, 70 (03) : 455 - 468
  • [32] Secondary radiation dose during high-energy total body irradiation
    Janiszewska, M.
    Polaczek-Grelik, K.
    Raczkowski, M.
    Szafron, B.
    Konefal, A.
    Zipper, W.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 (05) : 459 - 466
  • [33] Tissue-equivalent proportional counters in a high-energy neutron field at CERN
    Lim, T
    BottollierDepois, JF
    Festag, JG
    Golnik, H
    Grillmaier, RE
    Hofert, M
    Lindborg, L
    NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE, 1997, 2867 : 300 - 305
  • [34] CONDUCTIMETRIC DOMIMETRY, A CALORIMETRIC METHOD FOR MEASURING DOSES OF PULSED HIGH-ENERGY RADIATION
    SCHMIDT, KH
    BUCK, WL
    RADIATION RESEARCH, 1969, 39 (02) : 471 - &
  • [35] Form-factor measurements on chromium with high-energy synchrotron radiation
    Strempfer, J
    Brückel, T
    Caliebe, W
    Vernes, A
    Ebert, H
    Prandl, W
    Schneider, JR
    EUROPEAN PHYSICAL JOURNAL B, 2000, 14 (01): : 63 - 72
  • [36] Retarding field energy analyzer for high energy pulsed electron beam measurements
    Hu, Jing
    Rovey, Joshua L.
    Zhao, Wansheng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (01):
  • [37] Dose evaluation in lung-equivalent media in high-energy photon external radiotherapy
    Duch, M. A.
    Carrasco, P.
    Ginjaume, M.
    Jornet, N.
    Ortega, X.
    Ribas, M.
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 43 - 47
  • [38] Form-factor measurements on chromium with high-energy synchrotron radiation
    J. Strempfer
    Th. Brückel
    W. Caliebe
    A. Vernes
    H. Ebert
    W. Prandl
    J.R. Schneider
    The European Physical Journal B - Condensed Matter and Complex Systems, 2000, 14 : 63 - 72
  • [39] RADIOTHERAPY WITH HIGH-ENERGY RADIATION
    不详
    WHO CHRONICLE, 1963, 17 (05) : 185 - 186
  • [40] Strongly coupled plasmas in high-energy physics
    Thoma, MH
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2004, 32 (02) : 738 - 741