An artificial patient for pure-tone audiometry

被引:4
|
作者
Kocian, Alexander [1 ]
Cattani, Guido [2 ]
Chessa, Stefano [1 ]
Grolman, Wilko [2 ,3 ]
机构
[1] Univ Pisa, Dept Comp Sci, Largo B Pontecorvo 3, I-56127 Pisa, Italy
[2] Univ Utrecht, Univ Med Ctr Utrecht, Brain Ctr Rudolf Magnus, NL-3508 GA Utrecht, Netherlands
[3] Causse Ear Clin, Traverse Beziers, F-34440 Colombiers, France
关键词
Pure-tone audiometry; Real time; Signal processing; Noise injection; On-off keying; HEARING; TIME;
D O I
10.1186/s13636-018-0131-y
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The successful treatment of hearing loss depends on the individual practitioner's experience and skill. So far, there is no standard available to evaluate the practitioner's testing skills. To assess every practitioner equally, the paper proposes a first machine, dubbed artificial patient (AP), mimicking a real patient with hearing impairment operating in real time and real environment. Following this approach, we develop a multiple-input multiple-output auditory model that synthesizes various types of hearing loss as well as elements from psychoacoustics such as false response and reaction time. The model is then used to realize a hardware implementation, comprising acoustic and vibration sensors, sound cards, and a fanless personal computer. The AP returns a feedback signal to the practitioner upon perceiving a valid test tone at the hearing threshold analogous to a real patient. The AP is derived within a theoretical framework in contrast to many other solutions. The AP handles masked air-conduction and bone-conduction hearing levels in the range from 5 to 80 dB and from -20 to 70 dB, respectively, both at 1 kHz. The frequency range is confined within 250 and 8000 Hz. The proposed approach sets a new quality standard for evaluating practitioners.
引用
下载
收藏
页数:11
相关论文
共 50 条
  • [21] OTOLOGY AUDIOLOGY .5. CONDITIONED PURE-TONE AUDIOMETRY
    ROSE, WR
    VETERINARY MEDICINE & SMALL ANIMAL CLINICIAN, 1977, 72 (06): : 1090 - &
  • [22] OCCLUSION EFFECT IN BONE CONDUCTION PURE-TONE AND SPEECH AUDIOMETRY
    EDGERTON, BJ
    KLODD, DA
    JOURNAL OF THE AMERICAN AUDIOLOGY SOCIETY, 1977, 2 (04): : 151 - 158
  • [23] USE AND LIMITATIONS OF MASKING NOISE IN PURE-TONE AND SPEECH AUDIOMETRY
    LIDEN, G
    AUDIOLOGY, 1971, 10 (02): : 115 - +
  • [24] EFFECTS OF EXPERIMENTER BIAS UPON PURE-TONE AND SPEECH AUDIOMETRY
    HIPSKIND, NM
    RINTELMANN, WF
    JOURNAL OF AUDITORY RESEARCH, 1969, 9 (04): : 298 - 305
  • [25] HEARING IMPAIRMENT FOR SPEECH - EVALUATION FROM PURE-TONE AUDIOMETRY
    KRYTER, KD
    ARCHIVES OF OTOLARYNGOLOGY, 1963, 77 (06): : 598 - 602
  • [26] Tactile responses in pure-tone audiometry: a saccule function? Reply
    Mishra, Prasun
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2013, 270 (09) : 2577 - 2577
  • [27] Assessment of hearing loss by pure-tone audiometry in patients with mucopolysaccharidoses
    Lin, Hsiang-Yu
    Shih, Shou-Chuan
    Chuang, Chih-Kuang
    Lee, Kuo-Sheng
    Chen, Ming Ren
    Lin, Hung-Ching
    Chiu, Pao Chin
    Niu, Dau-Ming
    Lin, Shuan-Pei
    MOLECULAR GENETICS AND METABOLISM, 2014, 111 (04) : 533 - 538
  • [28] Automated Pure-Tone Audiometry: An Analysis of Capacity, Need, and Benefit
    Margolis, Robert H.
    Morgan, Donald E.
    AMERICAN JOURNAL OF AUDIOLOGY, 2008, 17 (02) : 109 - 113
  • [29] EVALUATION OF PURE-TONE AUDIOMETRY AND IMPEDANCE SCREENING IN INFANT SCHOOLCHILDREN
    HOLTBY, I
    FORSTER, DP
    JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 1992, 46 (01) : 21 - 25
  • [30] RELIABILITY OF CONDITIONED GSR PURE-TONE AUDIOMETRY WITH ADULT MALES
    CHAIKLIN, JB
    VENTRY, IM
    BARRETT, LS
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1961, 4 (03): : 269 - 280