Improvement of RIKEN 18 GHz electron cyclotron resonance ion source using aluminum tube

被引:21
|
作者
Nakagawa, T
Miyazawa, Y
Hemmi, M
Chiba, T
Inabe, N
Kase, M
Kageyama, T
Kamigaito, O
Goto, A
Yano, Y
机构
关键词
electron-cyclotron-resonance ion source; aluminum tube; highly charged ions; gas mixing;
D O I
10.1143/JJAP.35.4077
中图分类号
O59 [应用物理学];
学科分类号
摘要
We measured the beam intensity of highly charged argon and krypton ions covering the inner wall of a plasma chamber with an aluminum tube. The beam intensity was enhanced strongly and gas mixing was found to be unnecessary.
引用
收藏
页码:4077 / 4078
页数:2
相关论文
共 50 条
  • [33] Enhancement of Ar8+ ion beam intensity from RIKEN 18 GHz electron cyclotron resonance ion source by optimizing the magnetic field configuration
    Higurashi, Y
    Nakagawa, T
    Kidera, M
    Aihara, T
    Kase, M
    Yano, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2003, 42 (6A): : 3656 - 3657
  • [34] Implementation of an operator intervention system for remote control of the RIKEN 28 GHz superconducting electron cyclotron resonance ion source
    Uchiyama, A.
    Furukawa, K.
    Higurashi, Y.
    Nakagawa, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [35] Effect of magnetic-field configuration on the beam intensity from electron cyclotron resonance ion source and RIKEN superconducting electron cyclotron resonance ion source
    Nakagawa, T.
    Higurashi, Y.
    Kidera, M.
    Aihara, T.
    Kase, M.
    Goto, A.
    Yano, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03):
  • [36] Enhancement of Ar8+ current extracted from RIKEN 18 GHz electron cyclotron resonance ion source by moving the plasma electrode toward the resonance zone
    Higurashi, Y
    Nakagawa, T
    Kidera, M
    Aihara, T
    Kase, M
    Yano, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (08): : 5134 - 5135
  • [37] Demagnetization analysis of an 18 GHz electron cyclotron resonance ion source permanent magnet hexapole
    Mclain, J.
    Scott, R.
    Vondrasek, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2025, 96 (02):
  • [38] A new 18 GHz room temperature electron cyclotron resonance ion source for highly charged ion beams
    Koivisto, H.
    Ikonen, A.
    Kalvas, T.
    Kosonen, S.
    Kronholm, R.
    Marttinen, M.
    Tarvainen, O.
    Toivanen, V.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (02):
  • [39] Note: Effect of hot liner in producing 40,48Ca beam from RIKEN 18-GHz electron cyclotron resonance ion source
    Ozeki, K.
    Higurashi, Y.
    Kidera, M.
    Nakagawa, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (01):
  • [40] Effect of the plasma electrode position and shape on the beam intensity of the highly charged ions from RIKEN 18 GHz electron-cyclotron-resonance ion source
    Higurashi, Y
    Nakagawa, T
    Kidera, M
    Aihara, T
    Kobayashi, K
    Kase, M
    Goto, A
    Yano, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03):