Change in tibiofemoral rotational alignment during total knee arthroplasty

被引:39
|
作者
Watanabe, Satoshi [1 ]
Sato, Takashi [2 ]
Omori, Go [3 ]
Koga, Yoshio [2 ]
Endo, Naoto [1 ]
机构
[1] Niigata Univ, Grad Sch Med & Dent Sci, Div Orthopaed Surg, Dept Regenerat & Transplant Med, Niigata, Japan
[2] Niigata Med Ctr, Dept Orthopaed Surg, Niigata, Japan
[3] Niigata Univ, Ctr Transdisciplinary Res, Niigata, Japan
关键词
LOWER-EXTREMITY ALIGNMENT; COMPUTED-TOMOGRAPHY; COMPONENT ROTATION; IMPLANT ALIGNMENT; TIBIAL COMPONENT; MALROTATION; POSITION; AXIS; OSTEOARTHRITIS; VARIABILITY;
D O I
10.1007/s00776-014-0565-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Rotational mismatch between femoral and tibial components has been recognized as a risk factor of unsuccessful total knee arthroplasty (TKA), but a main cause of rotational mismatch is uncertain. This study aims to evaluate rotational alignment of the knee by measuring both component rotation and version of the knee in TKA. Fifty-one TKAs (mean age 73.7 years) were included in this study. The three dimensional, weight-bearing knee alignment was measured before and after TKA. A transepicondylar axis was referenced to femoral component rotation, and an anteroposterior axis of the tibia (middle of posterior cruciate ligament attachment to medial border of patella tendon attachment) was referenced to tibial component rotation. Knee rotational angle was defined as the angle between these two axes. The mean preoperative knee rotation angle of 9.7A degrees (+/- 8.5A degrees) internal rotation was significantly reduced to 1.8A degrees (+/- 7.3A degrees) external rotation after TKA. Twenty-one of 51 knees (41 %) exhibited rotational mismatch (> 10A degrees) preoperatively, and this number was reduced to eight knees (16 %) post-TKA. The femoral component was rotationally aligned within 5A degrees of neutral in all knees, while rotational alignment of the tibial component showed a high degree of variability (range 20.7A degrees internal rotation to 17.2A degrees external rotation). Rotational malposition of the tibial component was considered to be a main factor of rotational mismatch of the knee after TKA.
引用
收藏
页码:571 / 578
页数:8
相关论文
共 50 条
  • [41] Techniques for filling tibiofemoral bone defects during revision total knee arthroplasty
    Huten, Denis
    Pasquier, Gilles
    Lambotte, Jean-Christophe
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (01)
  • [42] Rotational alignment of femoral component with computed-assisted surgery (CAS) during total knee arthroplasty
    Michaut, M.
    Beaufils, P.
    Galaud, B.
    Abadie, P.
    Boisrenoult, P.
    Fallet, L.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2008, 94 (06): : 580 - 584
  • [43] From tibiofemoral instability to dislocation in total knee arthroplasty
    Pietsch, M.
    Hofmann, S.
    ORTHOPADE, 2007, 36 (10): : 917 - +
  • [44] Femoral rotational alignment using the tibial shaft axis in total knee arthroplasty
    Stiehl, JB
    Cherveny, PM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (331) : 47 - 55
  • [45] Distal rotational alignment of the Chinese femur and its relevance in total knee arthroplasty
    Yip, DKH
    Zhu, YH
    Chiu, KY
    Ng, TP
    JOURNAL OF ARTHROPLASTY, 2004, 19 (05): : 613 - 619
  • [46] Kinematic component alignment in total knee arthroplasty leads to better restoration of natural tibiofemoral kinematics compared to mechanic alignment
    Maderbacher, Guenther
    Keshmiri, Armin
    Krieg, Bernd
    Greimel, Felix
    Grifka, Joachim
    Baier, Clemens
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (05) : 1427 - 1433
  • [47] Functional Outcome and Rotational Alignment of Femoral Component in Unnavigated Total Knee Arthroplasty
    Madhukar, Vignesh D.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (04): : 476 - 487
  • [48] Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty
    Kanekasu, K
    Kondo, M
    Kadoya, Y
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (434) : 193 - 197
  • [49] Kinematic component alignment in total knee arthroplasty leads to better restoration of natural tibiofemoral kinematics compared to mechanic alignment
    Günther Maderbacher
    Armin Keshmiri
    Bernd Krieg
    Felix Greimel
    Joachim Grifka
    Clemens Baier
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1427 - 1433
  • [50] Tibiofemoral Alignment in Posterior Stabilized Total Knee Arthroplasty: Static Alignment Does Not Predict Dynamic Tibial Plateau Loading
    Miller, Emily J.
    Pagnano, Mark W.
    Kaufman, Kenton R.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (08) : 1068 - 1074