Dynamic Characteristic of Conductor After Ice-Shedding and Simulation Analysis of the Tension Insulator String

被引:1
|
作者
Zhongbin, Lv [1 ]
Liu, Xiaohui [2 ]
Zhang, Bo [1 ]
Yaguang, Tao [1 ]
Li, Fangyu [1 ,3 ]
Qing, Li [1 ]
Yan, Bo [4 ]
机构
[1] State Grid Henan Elect Power Res Inst, Zhengzhou 450052, Peoples R China
[2] Chongqing Jiaotong Univ, State Key Lab Mt Bridge & Tunnel Engn, Chongqing 400074, Peoples R China
[3] Chongqing Jiaotong Univ, Sch Civil Engn, Chongqing 400074, Peoples R China
[4] Chongqing Univ, Coll Aerosp Engn, Chongqing 400044, Peoples R China
关键词
Transmission line; ice-shedding; electrical power fitting; finite element simulation; tension insulator string; TRANSMISSION-LINES; FAILURE ANALYSIS; BALL-EYE; STRESS;
D O I
10.1109/ACCESS.2022.3215491
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electric power fittings are the link between conductors and transmission towers, and it is essential to improve their ability to withstand damage. To obtain the actual load of electric power fittings and study the stress of each electric power fitting under the actual load, a transmission line model of catenary-shaped and an integral model of tension insulator string are established in this paper. Then, conductors with a uniform thickness of ice coating and ice shedding process are simulated by changing density method. The results show that the maximum dynamic tension of the conductor of the isolated span transmission line is greater than the static tension of conductor icing only when the length of the ice-shedding section is small. Under any ice-shedding condition, the maximum dynamic tension of the conductor of the multi-span transmission line will be close to or greater than the static tension after conductor icing. When the form conductor tension is loaded on the tension insulator string, it can be found that the most dangerous fitting in the tension insulator string is found, and the stress analysis is carried out on the key connecting fittings, which provides a reference for the design and optimization of electric power fitting.
引用
收藏
页码:118484 / 118497
页数:14
相关论文
共 50 条
  • [21] Numerical modelling of the dynamic response of ice-shedding on electrical transmission lines
    Fekr, MR
    McClure, G
    ATMOSPHERIC RESEARCH, 1998, 46 (1-2) : 1 - 11
  • [22] Modeling of Transmission Conductor Based on Two-node Isoparametric Truss Elements and Application for Ice-shedding Analysis
    Xie, Yunyun
    Tang, Rui
    Huang, Linyan
    Ding, Huaiping
    2018 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2018,
  • [23] Simulation of ice-shedding of transmission tower-line system in heavy ice regions
    Yan, Zhi-Tao
    Li, Zheng-Liang
    Wang, Zhi-Song
    Gongcheng Lixue/Engineering Mechanics, 2010, 27 (01): : 209 - 214
  • [24] SIMULATION OF ICE-SHEDDING ON ELECTRICAL TRANSMISSION-LINES USING ADINA
    JAMALEDDINE, A
    MCCLURE, G
    ROUSSELET, J
    BEAUCHEMIN, R
    COMPUTERS & STRUCTURES, 1993, 47 (4-5) : 523 - 536
  • [25] Experimental study on dynamic response characteristics of isolated-span transmission lines after ice-shedding
    Huang, Guizao
    Yan, Bo
    Guo, Yujun
    Zhang, Bo
    Wu, Guangning
    HIGH VOLTAGE, 2023, 8 (01) : 196 - 208
  • [26] Dynamic impact effects on tower-line system due to ice-shedding
    Shen, Guo-Hui
    Yuan, Guang-Hui
    Sun, Bing-Nan
    Lou, Wen-Juan
    Gongcheng Lixue/Engineering Mechanics, 2010, 27 (05): : 210 - 217
  • [27] Mechanical Characteristic Analysis of Interphase Spacers in Double-Circuit Lines Under Ice-Shedding Jump Conditions
    Wang, Feng
    Ye, Jiaxuan
    Zhang, Tong
    Liu, Zhangjun
    PROCESSES, 2025, 13 (02)
  • [28] Field experiments on ice-accretion and ice-shedding processes of power transmission lines based on a conductor segment model
    Lou, Wenjuan
    Zhang, Yuelong
    Xu, Haiwei
    Huang, Mingfeng
    Zhang, Baiyan
    Bian, Rong
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2022, 55 (03): : 27 - 35
  • [29] Risk Assessment Method of Overhead Line after Ice-shedding Under Ice and Wind loads
    Huang Huan
    Chen Yifei
    Mao Xianyin
    Yang Lin
    Zhang Yizhao
    Yang Qi
    Zhang Qili
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [30] Ice-shedding characteristic of 1000 kV AC double circuit transmission line on the same tower
    Hu, Wei
    Chen, Yong
    Cai, Wei
    Meng, Xiao-Bo
    Wang, Li-Ming
    Fu, Guan-Jun
    Zhu, Pu-Xuan
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (01): : 275 - 280