Measurement of RBC agglutination with microscopic cell image analysis in a microchannel chip

被引:1
|
作者
Cho, Chi Hyun [1 ]
Kim, Ju Yeon [1 ]
Nyeck, Agnes E. [1 ]
Lim, Chae Seung [1 ]
Hur, Dae Sung [2 ]
Chung, Chanil [2 ]
Chang, Jun Keun [2 ]
An, Seong Soo A. [3 ]
Shin, Sehyun [4 ]
机构
[1] Korea Univ, Coll Med, Dept Lab Med, Seoul 136705, South Korea
[2] Nanoentek Inc, Seoul, South Korea
[3] Kyungwon Univ, Gachon Bionano Res Inst, Coll Bionano Technol, Songnam, Gyeonggi Do, South Korea
[4] Korea Univ, Sch Mech Engn, Seoul 136713, South Korea
关键词
Agglutination; scoring; C-reader; microchannel chip; CRAT; LATEX AGGLUTINATION; GEL TEST; ANTIGEN; COUNTER;
D O I
10.3233/CH-131673
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Since Landsteiner's discovery of ABO blood groups, RBC agglutination has been one of the most important immunohematologic techniques for ABO and RhD blood groupings. The conventional RBC agglutination grading system for RhD blood typings relies on macroscopic reading, followed by the assignment of a grade ranging from (-) to (4+) to the degree of red blood cells clumping. However, with the new scoring method introduced in this report, microscopically captured cell images of agglutinated RBCs, placed in a microchannel chip, are used for analysis. Indeed, the cell images' pixel number first allows the differentiation of agglutinated and non-agglutinated red blood cells. Finally, the ratio of agglutinated RBCs per total RBC counts (CRAT) from 90 captured images is then calculated. During the trial, it was observed that the agglutinated group's CRAT was significantly higher (3.77-0.003) than that of the normal control (0). Based on these facts, it was established that the microchannel method was more suitable for the discrimination between agglutinated RBCs and non-agglutinated RhD negative, and thus more reliable for the grading of RBCs agglutination than the conventional method.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 50 条
  • [21] Application of a new portable microscopic somatic cell counter with disposable plastic chip for milk analysis
    Moon, J. S.
    Koo, H. C.
    Joo, Y. S.
    Jeon, S. H.
    Hur, D. S.
    Chung, C. I.
    Jo, H. S.
    Park, Y. H.
    JOURNAL OF DAIRY SCIENCE, 2007, 90 (05) : 2253 - 2259
  • [22] Microscopic optical path length difference and polarization measurement system for cell analysis
    Satake, H.
    Ikeda, K.
    Kowa, H.
    Hoshiba, T.
    Watanabe, E.
    THIRD INTERNATIONAL CONFERENCE ON PHOTONICS SOLUTIONS (ICPS2017), 2018, 10714
  • [23] Image Recognition and Counting for the Bacilli Cell Based on the Microscopic Image
    Tan, Min
    Zhong, Jikang
    Zhang, Guozhao
    Hu, Zhixiang
    MATERIAL SCIENCE, CIVIL ENGINEERING AND ARCHITECTURE SCIENCE, MECHANICAL ENGINEERING AND MANUFACTURING TECHNOLOGY II, 2014, 651-653 : 2318 - +
  • [24] DNA ploidy analysis of breast tumor cell by the system of Hadamard transform microscopic image analysis
    Tang, HW
    Mei, EW
    Chen, GQ
    Zeng, YE
    Mao, YR
    He, P
    Shi, ZJ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1997, 18 (02): : 216 - 219
  • [25] Measurement of Single-Cell Deformability Using Impedance Analysis on Microfluidic Chip
    Kim, Dongil
    Choi, Eunpyo
    Choi, Sung Sik
    Lee, Sangho
    Park, Jungyul
    Yun, Kwang-Seok
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (12)
  • [26] Microscopic image stitching for cytopatological analysis
    Dogan, H.
    Baykal, E.
    Ekinci, M.
    Ercin, M. E.
    Ersoz, S.
    VIRCHOWS ARCHIV, 2017, 471 : S205 - S205
  • [27] Accurate measurement of peripheral blood mononuclear cell concentration using image cytometry to eliminate RBC-induced counting error
    Chan, Leo Li-Ying
    Laverty, Daniel J.
    Smith, Tim
    Nejad, Parham
    Hei, Hillary
    Gandhi, Roopali
    Kuksin, Dmitry
    Qiu, Jean
    JOURNAL OF IMMUNOLOGICAL METHODS, 2013, 388 (1-2) : 25 - 32
  • [28] Accurate measurement of peripheral blood mononuclear cell concentration using image cytometry to eliminate RBC-induced counting error
    Chan, Leo
    Laverty, Daniel
    Smith, Tim
    Nejad, Parham
    Hei, Hillary
    Gandhi, Roopali
    Kuksin, Dmitry
    Qiu, Jean
    JOURNAL OF IMMUNOLOGY, 2013, 190
  • [29] Settling velocity and size distribution measurement of anaerobic granular sludge using microscopic image analysis
    Tassew, Fasil A.
    Bergland, Wenche Hennie
    Dinamarca, Carlos
    Bakke, Rune
    JOURNAL OF MICROBIOLOGICAL METHODS, 2019, 159 : 81 - 90
  • [30] Experiences in the measurement of RBC-bound IgG as markers of cell age
    Paleari, R
    Ceriotti, F
    Azzario, F
    Maccioni, L
    Galanello, R
    Mosca, A
    BIOELECTROCHEMISTRY, 2004, 62 (02) : 175 - 179