Sampling and analysis of pesticides in the gas phase of air: method validation using a volatilization chamber

被引:0
|
作者
Freixo, Joao L. [1 ]
Dores, Eliana F. G. de C. [1 ]
Villa, Ricardo D. [1 ]
机构
[1] Univ Fed Mato Grosso, Dept Chem, ICET, BR-78060900 Cuiaba, MT, Brazil
关键词
CURRENTLY USED PESTICIDES; AMBIENT AIR; ORGANOCHLORINE PESTICIDES; MASS-SPECTROMETRY; ATMOSPHERE; EXTRACTION; RESIDUES; CHINA;
D O I
10.1039/c5ay01691f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study evaluated the efficiency of Tenax (R) resin to sample the pesticides, atrazine, chlorpyrifos, alpha,beta-endosulfan, metolachlor and trifluralin, from contaminated air in a volatilization chamber. The air contamination was performed by adding pesticide masses in the range of 100-750 ng in a chamber at an air flow rate of 2.60 L min(-1) at 35 degrees C for 12 h. After volatilization, the pesticides followed the airflow toward the cartridges packed with two sequential sections of Tenax (R) resin, separated by glass wool. In this apparatus, the sampling efficiency remained between 82 and 119%, with RSD% lower than 14%. The method quantitation limit (MQL) was 53.4 ng m(-3) for all studied analytes. Comparative trials with the resin XAD (R)-2 showed the sampling efficiency between 83 and 92%, with CV less than 10%. The volatilization chamber also allowed the evaluation of the volatilization profile of each analyte and helped in the sampling cartridge setting, in order to prevent the breakthrough effect.
引用
收藏
页码:8255 / 8261
页数:7
相关论文
共 50 条
  • [41] ANALYSIS OF SAMPLING PHASE-LOCKED LOOPS USING THE AVERAGING METHOD
    PESTRYAKOV, AV
    RADIOTEKHNIKA I ELEKTRONIKA, 1990, 35 (11): : 2334 - 2340
  • [42] INSITU SAMPLING SYSTEM FOR THERMAL VOLATILIZATION ANALYSIS OF NONVOLATILE MATERIALS BY GAS CHROMATOGRAPHY MASS SPECTROMETRY
    SHEN, J
    ANALYTICAL CHEMISTRY, 1977, 49 (06) : 886 - 888
  • [43] METHOD OF SAMPLING CONDENSED TRACE CONTAMINANTS IN EXHALED AIR FOR SUBSEQUENT GAS-CHROMATOGRAPHIC ANALYSIS
    SOTNIKOV, EE
    KOSMICHESKAYA BIOLOGIYA I AVIAKOSMICHESKAYA MEDITSINA, 1975, 9 (02): : 73 - 75
  • [44] Technical note: Conditions for using the floating chamber method to estimate air-water gas exchange
    Kremer, JN
    Nixon, SW
    Buckley, B
    Roques, P
    ESTUARIES, 2003, 26 (4A): : 985 - 990
  • [45] Technical note: Conditions for using the floating chamber method to estimate air-water gas exchange
    James N. Kremer
    Scott W. Nixon
    Betty Buckley
    Patrick Roques
    Estuaries, 2003, 26 : 985 - 990
  • [46] FIXED POINT RH EQUILIBRIUM OF GAS SENSOR TEST CHAMBER USING SIMPLE AIR BUBBLER METHOD
    Abd Rashid, Amirul
    Saad, Nor Hayati
    Sheng, Daniel Bien Chia
    Yee, Lee Wai
    Jaffar, Ahmed
    JURNAL TEKNOLOGI, 2015, 76 (10): : 11 - 15
  • [47] Sampling method for determination of pesticides in the atmosphere using silica gel column
    Watanabe, T
    JOURNAL OF PESTICIDE SCIENCE, 1996, 21 (02): : 147 - 152
  • [48] Development and validation of multiresidue method for organophosphorus pesticides in lanolin using gas chromatography-tandem mass spectrometry
    Gupta, Neha
    Singh, Rakhi
    Nayak, Sumant Kumar
    Das, Mukul
    Jan, Kulsum
    JOURNAL OF MASS SPECTROMETRY, 2022, 57 (11):
  • [49] Validation of Multyresidue Analytical Method for Organochlorine Pesticides in Snakefruit Using Gas Chromatography-Electron Capture Detector
    Raharjo, Tri Joko
    Sutriyanto, Bambang
    Anugrahwati, Mai
    Aprilita, Nurul Hidayat
    AGRITECH, 2013, 33 (02): : 189 - 196
  • [50] Development and validation by accuracy profile of a method for the analysis of monoterpenes in indoor air by active sampling and thermal desorption-gas chromatography-mass spectrometry
    Marlet, Christelle
    Lognay, Georges
    TALANTA, 2010, 82 (04) : 1230 - 1239