Promethee: An alpha low level waste assay system using passive and active neutron measurement methods

被引:4
|
作者
Passard, C [1 ]
Mariani, A
Jallu, F
Romeyer-Dherbey, J
Recroix, H
Rodriguez, M
Loridon, J
Denis, C
Toubon, H
机构
[1] French Atom Energy Commiss, DED, SCCD, LDMN, F-13108 St Paul Les Durance, France
[2] COGEMA, F-78141 Velizy Villacoublay, France
关键词
neutron measurement; fissile matter; detection limit;
D O I
10.13182/NT02-A3341
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The development of a passive-active neutron assay system for alpha low level waste characterization at the French Atomic Energy Commission is discussed. Less than 50 Bq[alpha] (about 50 mug Pu) per gram of crude waste must be measured in 118-l "European" drums in order to reach the requirements for incinerating wastes. Detection limits of about 0.12 mg of effective Pu-239 in total active neutron counting, and 0.08 mg of effective Pu-239 coincident active neutron counting, may currently be detected (empty cavity, measurement time of 15 min, neutron generator emission of 1.6 x 10(8) s(-1) [4pi]). The most limiting parameters in terms of performances are the matrix of the drum-its composition (H, Cl...), its density, and its heterogeneity degree-and the localization and self-shielding properties of the contaminant.
引用
收藏
页码:303 / 314
页数:12
相关论文
共 50 条
  • [41] Small-scale (sub-organ and cellular level) alpha-particle dosimetry methods using an iQID digital autoradiography imaging system
    Robin Peter
    Brenda M. Sandmaier
    Michael P. Dion
    Sofia H. L. Frost
    Erlinda B. Santos
    Aimee Kenoyer
    Donald K. Hamlin
    D. Scott Wilbur
    Robert D. Stewart
    Darrell R. Fisher
    Kai Vetter
    Youngho Seo
    Brian W. Miller
    Scientific Reports, 12
  • [42] A system for low-level the cosmogenic 22Na radionuclide measurement by gamma-gamma coincidence method using BGO detectors
    Zhang, Weihua
    Yi, Jing
    Mekarski, Pawel
    Hoffman, Ian
    Ungar, Kurt
    Leppanen, Ari-Pekka
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 287 (02) : 551 - 555
  • [43] Experimental study on an electric vehicle heat pump system with multi-level waste heat recovery using a vapor injection technique at low ambient temperatures
    Lee, Sangwook
    Chung, Yoong
    Jeong, Yeonwoo
    Kim, Min Soo
    ENERGY CONVERSION AND MANAGEMENT, 2022, 267
  • [44] System-level integration of active silicon photonic biosensors using Fan-Out Wafer-Level-Packaging for low cost and multiplexed point-of-care diagnostic testing
    Laplatine, Loic
    Luan, Enxiao
    Cheung, Karen
    Ratner, Daniel M.
    Dattner, Yonathan
    Chrostowski, Lukas
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 : 1610 - 1617
  • [45] MEASUREMENT OF LOW-LEVEL RA-226 IN HUMAN BONE BY USING RA-225 TRACER AND ALPHA-SPECTROMETRY - APPROACH WITHOUT USE OF BA CARRIER
    YAMAMOTO, M
    KAWAMURA, H
    IGARASHI, Y
    SHIRAISHI, K
    UENO, K
    RADIOCHIMICA ACTA, 1991, 55 (03) : 163 - 166
  • [46] Determination of low level nitrate/nitrite contamination using SERS-active Ag/ITO substrates coupled to a self-designed Raman spectroscopy system
    Tran, Chi T. K.
    Tran, Huyen T. T.
    Bui, Hien T. T.
    Dang, Trung Q.
    Nguyen, Liem Q.
    JOURNAL OF SCIENCE-ADVANCED MATERIALS AND DEVICES, 2017, 2 (02): : 172 - 177
  • [47] Effects of low-level laser therapy following surgical extraction of the lower third molar with objective measurement of swelling using a three-dimensional system
    Koparal, Mahmut
    Kucuk, Ayse Ozcan
    Alan, Hilal
    Asutay, Fatih
    Avci, Mehmet
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2018, 15 (04) : 3820 - 3826
  • [48] Ex vivo studies for the passive transdermal delivery of low-dose naltrexone from a cream; detection of naltrexone and its active metabolite, 6β-naltrexol, using a novel LC Q-ToF MS assay
    Dodou, Kalliopi
    Armstrong, Andrew
    Kelly, Ivan
    Wilkinson, Simon
    Carr, Kevin
    Shattock, Paul
    Whiteley, Paul
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2015, 20 (06) : 694 - 701
  • [49] A biotech measurement software system using controlled features for determining the level of psycho-emotional tension on man-machine system operators by bio-active points based on fuzzy logic measures
    Al-Kasasbeh, Riad Taha
    Zaubi, Mohammad Ali Abdalla
    Korenevskiy, Nikolay
    Al-Shawawreh, Fawaz
    Alshamasin, Mahdi Salman
    Ionescu, Florin
    INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2014, 22 (04) : 375 - 395
  • [50] DETERMINATION OF AMBIENT AEROSOL SULFUR USING A CONTINUOUS FLAME PHOTOMETRIC DETECTION SYSTEM .2. THE MEASUREMENT OF LOW-LEVEL SULFUR CONCENTRATIONS UNDER VARYING ATMOSPHERIC CONDITIONS
    DOTTAVIO, T
    GARBER, R
    TANNER, RL
    NEWMAN, L
    ATMOSPHERIC ENVIRONMENT, 1981, 15 (02) : 197 - 203