MiniMed 670G hybrid closed loop artificial pancreas system for the treatment of type 1 diabetes mellitus: overview of its safety and efficacy

被引:43
|
作者
Saunders, Aria [1 ]
Messer, Laurel H. [2 ]
Forlenza, Gregory P. [2 ]
机构
[1] Univ Colorado, Dept Bioengn, Denver, CO 80202 USA
[2] Univ Colorado, Barbara Davis Ctr, Aurora, CO USA
关键词
Artificial pancreas (AP); automated insulin delivery; continuous glucose monitor (CGM); hybrid closed loop; insulin pump; MiniMed; 670G; type; 1; diabetes; GLUCOSE MONITORING TECHNOLOGY; INSULIN DELIVERY; HOME USE; ADULTS; FEASIBILITY; ADOLESCENTS; FRAMEWORK; CHILDREN; EXERCISE; THERAPY;
D O I
10.1080/17434440.2019.1670639
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Automated insulin delivery for people with type 1 diabetes has been a major goal in the diabetes technology field for many years. While a fully automated system has not yet been accomplished, the MiniMed? 670G artificial pancreas (AP) system is the first commercially available insulin pump that automates basal insulin delivery, while still requiring user input for insulin boluses. Determining the safety and efficacy of this system is essential to the development of future devices striving for more automation. Areas Covered: This review will provide an overview of how the MiniMed 670G system works including its safety and efficacy, how it compares to similar devices, and anticipated future advances in diabetes technology currently under development. Expert Opinion: The ultimate goal of advanced diabetes technologies is to reduce the burden and amount of management required of patients with diabetes. In addition to reducing patient workload, achieving better glucose control and improving hemoglobin A1c (HbA1c) values are essential for reducing the threat of diabetes-related complications further down the road. Current devices come close to reaching these goals, but understanding the unmet needs of patients with diabetes will allow future technologies to achieve these goals more quickly.
引用
收藏
页码:845 / 853
页数:9
相关论文
共 50 条
  • [41] Hybrid Closed Loop Using a Do-It-Yourself Artificial Pancreas System in Adults With Type 1 Diabetes
    Nanayakkara, Natalie
    Sharifi, Amin
    Burren, David
    Elghattis, Yasser
    Jayarathna, Dulari K.
    Cohen, Neale
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (04): : 889 - 896
  • [42] A Comparison of Postprandial Glucose Control in the Medtronic Advanced Hybrid Closed-Loop System Versus 670G
    Weinzimer, Stuart A.
    Bailey, Ryan J.
    Bergenstal, Richard M.
    Nimri, Revital
    Beck, Roy W.
    Schatz, Desmond
    Ambler-Osborn, Louise
    Schweiger, Darja Smigoc
    von dem Berge, Thekla
    Sibayan, Judy
    Johnson, Mary L.
    Calhoun, Peter
    Phillip, Moshe
    Criego, Amy
    Carlson, Anders
    Martens, Thomas
    Beasley, Shannon
    Whipple, Diane
    Hyatt, Jamie
    Punel, Alina
    Grieme, Aimee
    Thomas, Lee Ann
    LaFrance, Amy
    Hasledalen, Caitlin
    Laffel, Lori
    Isganaitis, Elvira
    Freiner, Emily
    Desrochers, Hannah
    Turcotte, Christine
    Naik, Nisha
    Roethke, Lindsay
    Fisher, Margaret
    Nevo, Michal
    Bello, Rachel
    Hamou, Alona
    Hermon, Orna
    Horesh, Orit
    Mantzuri, Galit Shiovitch
    Drotz, Irit
    Yehiel, Nava
    Naveh, Rachel
    Haller, Michael
    Albanese-O'Neill, Anastasia
    Sheehan, Eleni
    Sheehan, Eleni
    Smith, Madison
    Jacobsen, Laura
    Adams, Janey
    Hosford, Jennifer
    Whyte, Loren
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (08) : 573 - 582
  • [43] Glycemic outcomes of children 2-6 years of age with type 1 diabetes during the pediatric MiniMed™ 670G system trial
    Forlenza, Gregory P.
    Ekhlaspour, Laya
    DiMeglio, Linda A.
    Fox, Larry A.
    Rodriguez, Henry
    Shulman, Dorothy I.
    Kaiserman, Kevin B.
    Liljenquist, David R.
    Shin, John
    Lee, Scott W.
    Buckingham, Bruce A.
    PEDIATRIC DIABETES, 2022, 23 (03) : 324 - 329
  • [44] Safety and efficacy of diluted insulin in a hybrid closed loop system in young children with type 1 diabetes
    Ashford, J.
    Myles, C.
    Nicol, E.
    Cooper, L.
    Thankamony, A.
    Walton-Betancourth, S.
    Hendriks, A. E. J.
    Marcovecchio, M. L.
    HORMONE RESEARCH IN PAEDIATRICS, 2024, 97 : 167 - 168
  • [45] Benefits and warnings after one year of Minimed 780 G hybrid closed loop pump treatment in type 1 diabetes adults
    Gouet, Didier
    Ducluzeau, Pierre Henri
    Andriantaolo, Harivola
    Cordroc'h, Claire
    Duengler, Frederique
    Gaulier, Sophie
    Godeau, Thierry
    Olivier, Celine
    Allix-Beguec, Caroline
    DIABETES EPIDEMIOLOGY AND MANAGEMENT, 2022, 8
  • [46] REMOTE AND IN CLINIC INITIATION OF ADVANCED HYBRID CLOSED LOOP SYSTEM MINIMED 780G IN CHILDREN AND ADOLESCENTS WITH TYPE 1 DIABETES
    Petrovski, G.
    Campbell, J.
    Al Khalaf, F.
    Umer, F.
    Almajaly, D.
    Day, E.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A220 - A220
  • [47] A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
    El-Khatib, Firas H.
    Russell, Steven J.
    Nathan, David M.
    Sutherlin, Robert G.
    Damiano, Edward R.
    SCIENCE TRANSLATIONAL MEDICINE, 2010, 2 (27) : 27ra27
  • [48] Closed-Loop Artificial Pancreas Therapy for Type 1 Diabetes
    Keren Zhou
    Diana Isaacs
    Current Cardiology Reports, 2022, 24 : 1159 - 1167
  • [49] Closed-Loop Artificial Pancreas Therapy for Type 1 Diabetes
    Zhou, Keren
    Isaacs, Diana
    CURRENT CARDIOLOGY REPORTS, 2022, 24 (09) : 1159 - 1167
  • [50] Corrigendum to "Hybrid Closed Loop Using a Do-It-Yourself Artificial Pancreas System in Adults With Type 1 Diabetes"
    不详
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (06): : 1523 - 1523