Pancreatic adenocarcinoma: dynamic 64-slice helical CT with perfusion imaging

被引:51
|
作者
Xu, Jin [1 ]
Liang, Zonghui [2 ]
Hao, Sijie [1 ]
Zhu, Li [2 ]
Ashish, Maskay [1 ]
Jin, Chen [1 ]
Fu, Deliang [1 ]
Ni, Quanxing [1 ]
机构
[1] Fudan Univ, Huashan Hosp, Pancreat Dis Inst, Dept Gen Surg, Shanghai 200040, Peoples R China
[2] Fudan Univ, Huashan Hosp, Pancreat Dis Inst, Dept Radiol, Shanghai 200040, Peoples R China
来源
ABDOMINAL IMAGING | 2009年 / 34卷 / 06期
关键词
Pancreas; Pancreatic adenocarcinoma; CT diagnosis; Helical CT; Perfusion CT; DUCTAL ADENOCARCINOMA; COMPUTED-TOMOGRAPHY; ANGIOGENESIS; CANCER; STROKE; TUMOR;
D O I
10.1007/s00261-009-9564-1
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Perfusion CT is able to outline blood perfusion changes in a tissue. Thus, in lesions of the tissues of the pancreas, this offers to increase the accuracy of CT diagnosis. In this study, our aim was to explore the perfusion characteristics of normal pancreas and pancreatic adenocarcinoma. Dynamic 64-slice helical CT was conducted in 36 patients with non-pancreatic disease and in 40 patients with histopathologically proven pancreatic adenocarcinoma. Perfusion parameters including blood flow (BF), blood volume (BV), and permeability surface area product (PS) were recorded. There was no significant difference noted between the distribution of BF, BV, and PS values in different regions of the pancreas, namely the head, neck, body, and tail (P > 0.05). The BF, BV, and PS of normal pancreas were recorded as 135.24 +/- A 48.36 ml min(-1) 100 g(-1), 200.55 +/- A 54.96 ml 100 g(-1), and 49.75 +/- A 24.27 ml min(-1) 100 g(-1), respectively. BF, BV, and PS values of the tumor tissue of pancreatic adenocarcinoma decreased significantly compared to normal pancreas (P < 0.05). Normal pancreas appears homogenous on perfusion CT. A significant decrease of BF, BV, and PS was observed in pancreatic adenocarcinoma. Dynamic 64-slice helical CT with perfusion imaging should be considered a potential modality to increase the accuracy of CT diagnosis for pancreatic adenocarcinoma.
引用
收藏
页码:759 / 766
页数:8
相关论文
共 50 条
  • [41] 64-Slice CT urography: 30 months of clinical experience
    Martingano, P.
    Stacul, F.
    Cavallaro, M.
    Casagrande, F.
    Cernic, S.
    Belgrano, M.
    Cova, M.
    RADIOLOGIA MEDICA, 2010, 115 (06): : 920 - 935
  • [42] Evaluation of Normal Adrenal Gland Volume by 64-slice CT
    Xuan Wang
    Zheng-yu Jin
    Hua-dan Xue
    Wei Liu
    Hao Sun
    Yu Chen
    Kai Xu
    ChineseMedicalSciencesJournal, 2012, 27 (04) : 220 - 224
  • [43] 64-slice CT angiography for the detection of coronary artery stenoses
    Carol Lovegrove
    Nature Clinical Practice Cardiovascular Medicine, 2006, 3 (1): : 7 - 7
  • [44] Myocardial infarction imaging by early and late-phase 64-slice CT in comparison to MRI
    Nieman, Koen
    Shapiro, Michael
    Ferencik, Maros
    Nomura, Cesar
    Abbara, Suhny
    Hoffmann, Udo
    Jang, Ik-Kyung
    Brady, Thomas
    Cury, Ricardo
    CIRCULATION, 2006, 114 (18) : 384 - 385
  • [45] Caseous calcification of the mitral annulus imaged with 64-slice multidetector CT and magnetic resonance imaging
    Vanovermeire, Olivier M.
    Duerinckx, Andre J.
    Duncan, David A.
    Russell, Wilson G.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (3-4): : 553 - 559
  • [46] Evaluation of the Optimal Image Reconstruction Interval for Coronary Artery Imaging Using 64-slice CT
    Weininger, M.
    Ritter, C.
    Beer, M.
    Hahn, D.
    Beissert, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [47] Quantitative measures of coronary stenosis severity by 64-slice CT angiography and relation to physiologic significance of perfusion in nonobese patients: Comparison with stress myocardial perfusion imaging
    Sato, Akira
    Hiroe, Michiaki
    Tamura, Mieko
    Ohigashi, Hirokazu
    Nozato, Toshihiro
    Hikita, Hiroyuki
    Takahashi, Atsushi
    Aonuma, Kazutaka
    Isobe, Mitsuaki
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (04) : 564 - 572
  • [48] Evaluation of circle of Willis variations with 64-slice CT angiography
    Li, Qi
    Xie, Peng
    Lv, Fajin
    Luo, Tianyou
    NEUROLOGY, 2008, 70 (11) : A158 - A158
  • [49] Characterization of mandibular fractures using 64-slice multidetector CT
    Ogura, I.
    Kaneda, T.
    Mori, S.
    Sekiya, K.
    Ogawa, H.
    Tsukioka, T.
    DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (05) : 392 - 395
  • [50] Accuracy of 64-slice CT to detect noncalcified coronary plaques
    Leber, A.
    Becker, A.
    Von Ziegler, F. Z.
    Becker, C. B.
    Boekstegers, P.
    Knez, A.
    EUROPEAN HEART JOURNAL, 2006, 27 : 289 - 289