THE ELECTROCHEMICAL PROPERTIES OF FOUR DENTAL CASTING SUPRASTRUCTURE ALLOYS COUPLED WITH TITANIUM IMPLANTS

被引:13
|
作者
Tuna, Suleyman Hakan [1 ]
Pekmez, Nuran Ozcicek [2 ]
Keyf, Filiz [3 ]
Canli, Fulya [2 ]
机构
[1] Suleyman Demirel Univ, Dept Prosthodont, Fac Dent, TR-32200 Isparta, Turkey
[2] Hacettepe Univ, Dept Chem, Fac Sci, TR-06532 Ankara, Turkey
[3] Hacettepe Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
关键词
Corrosion; Dental casting alloys; Titanium implant; Electrochemical properties; Galvanic corrosion; CORROSION BEHAVIOR; METAL-IONS; ABUTMENTS; PH;
D O I
10.1590/S1678-77572009000500022
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: As the choice of suprastructure alloy to be combined with titanium for the oral cavity is still a much debated issue, the aim of this study was to investigate the electrochemical interaction of the suprastructure/implant couples under the determined experiment conditions. Material and Methods: The potentiodynamic polarization curves and open-circuit potentials (OCP) of four UCLA type suprastructures coupled with straight Swiss Plus implant fixtures were taken in Afnor type artificial saliva solution at 37 degrees C. The concentration of ions leached into artificial saliva solutions was estimated with ICP-MS. SEM images of the margins of suprastructure/implant couples were obtained before and after the electrochemical tests. Results: The OCP value of titanium became passive at the most negative potential. The lowest difference between the initial and constant OCP value was exhibited by the Au based suprastructure. Suprastructures made greater contributions to the potentiodynamic polarization curves of the implant/suprastructure couples. According to the ICP-MS results, Pd based and Au based couples dissolved less than Co-Ni based and Co-Cr based couples. Conclusions: Within the conditions this study, it may be concluded that the titanium implant forms a stable passive oxide layer in artificial saliva exposed to open air and does not affect the corrosion properties of the suprastructures. Pd based and Au based couples have been found to be more corrosion-resistant than base alloy couples.
引用
收藏
页码:467 / 475
页数:9
相关论文
共 50 条
  • [31] PROPERTIES OF TITANIUM DENTAL IMPLANTS PRODUCED BY ELECTRODISCHARGE COMPACTION
    LIFLAND, MI
    OKAZAKI, K
    CLINICAL MATERIALS, 1994, 17 (04): : 203 - 209
  • [32] A Review of Titanium Zirconium (TiZr) Alloys for Use in Endosseous Dental Implants
    Grandin, H. Michelle
    Berner, Simon
    Dard, Michel
    MATERIALS, 2012, 5 (08) : 1348 - 1360
  • [33] Biocompatibility of Surface-Modified Titanium Alloys for Use in Dental Implants
    Zhang, Jing-ying
    INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND INFORMATION ENGINEERING (CSIE 2015), 2015, : 443 - 447
  • [34] Growth of bioactive surfaces on titanium and its alloys for orthopaedic and dental implants
    Gil, FJ
    Padrós, A
    Manero, JM
    Aparicio, C
    Nilsson, M
    Planell, JA
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2002, 22 (01): : 53 - 60
  • [35] Recent Advances and Prospects in β-type Titanium Alloys for Dental Implants Applications
    Neto, Joao V. Calazans
    Celles, Cicero A. S.
    de Andrade, Catia S. A. F.
    Afonso, Conrado R. M.
    Nagay, Bruna E.
    Barao, Valentim A. R.
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2024, 10 (10): : 6029 - 6060
  • [36] STUDIES OF PROPERTIES OF TITANIUM ALLOYS FOR DENTAL PURPOSES
    CARTER, JM
    SMITH, DC
    JOURNAL OF DENTAL RESEARCH, 1967, 46 (1P1S) : 115 - &
  • [37] ELECTROCHEMICAL CHARACTERISTICS OF TITANIUM FOR DENTAL IMPLANTS IN CASE OF THE ELECTROLESS SURFACE MODIFICATION
    Klimecka-Tatar, D.
    ARCHIVES OF METALLURGY AND MATERIALS, 2016, 61 (02) : 923 - 926
  • [38] Electrochemical Behavior of Three CP Titanium Dental Implants in Artificial Saliva
    Kadowaki, Norma Terumi
    Santana Martinez, Gustavo Aristides
    Robin, Alain
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2009, 12 (03): : 363 - 366
  • [39] ELECTROCHEMICAL-BEHAVIOR OF TITANIUM AND DENTAL ALLOYS IN ARTIFICIAL SALIVA
    ELAGLI, K
    TRAISNEL, M
    HILDEBRAND, HF
    ELECTROCHIMICA ACTA, 1993, 38 (13) : 1769 - 1774
  • [40] Corrosion behavior of galvanically-coupled dental casting alloys.
    Vermilyea, S
    Benson, S
    Brantley, W
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1165 - 1165