Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3 fractures: a retrospective comparative study

被引:16
|
作者
Yu, Xiaofei [1 ,2 ]
Yu, Yadong [1 ,2 ]
Shao, Xinzhong [1 ,2 ]
Bai, Yanbin [1 ,2 ]
Zhou, Tong [1 ,2 ]
机构
[1] Hebei Med Univ, Hosp 3, Dept Hand Surg, 139 Ziqiang Rd, Shijiazhuang 050051, Hebei, Peoples R China
[2] Key Lab Biomech Hebei Prov, Shijiazhuang 050051, Hebei, Peoples R China
关键词
Unstable intra-articular fracture; Distal radius; Clinical outcome; Volar plate fixation; External fixation; DISTAL RADIUS FRACTURES; OPEN REDUCTION; DORSAL; COMPLICATIONS;
D O I
10.1186/s13018-019-1309-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThis study aimed to compare the radiographic and functional results of Arbeitsgemeinschaftfur Osteosynthesefragen (AO) type C2/C3 fracture of distal radius between volar locking plate (VLP) and external fixation (EF).MethodsIt was a retrospective comparative study. Between January 2015 and March 2018, a total of 62/117 patients who underwent EF (23) or VLP fixation (39) for AO type C2/C3 distal radius fractures were assessed. The follow-up period was at least 12months. Gartland-Werley scale and the disabilities of the arm, shoulder, and hand (DASH) scale were used to evaluate the overall functional outcomes; wrist range of motion and grip strength were measured. The radiographic parameters included radial inclination, volar tilt, radial length, ulnar variance, and articular step-off. All of the comparisons were performed using SPSS 21.0.ResultsThe mean follow-up time was 17.1months. At final visit, VLP performed better in wrist flexion (69.7 degrees vs 62.3 degrees, p<0.001), forearm pronation (73.1 degrees vs 64.8 degrees, p=0.027) and supination (70.6 degrees vs 63.1 degrees, p=0.033) than EF, but not different with regard to other kinematic parameters. No significant difference was found between two groups, in term of Gartland-Werley or DASH score (p>0.05). The ulnar variance and articular step-off was significantly more improved in VLP than EF group, being 0.6 vs 1.6mm (p=0.002) and 0.5 vs 1.2mm (p=0.007). The overall rate of complications did not differ in both groups (28.2% vs 34.5%) (p=0.587).ConclusionsCompared to EF, VLP fixation showed better performance in wrist mobility, correction of ulnar variance, and improving articular congruence, but with the comparable overall functional outcomes and complication rate.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3 fractures: a retrospective comparative study
    Xiaofei Yu
    Yadong Yu
    Xinzhong Shao
    Yanbin Bai
    Tong Zhou
    Journal of Orthopaedic Surgery and Research, 14
  • [2] Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: A retrospective study
    Rein, Susanne
    Schikore, Hartmut
    Schneiders, Wolfgang
    Amlang, Michael
    Zwipp, Hans
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (07): : 954 - 961
  • [3] Comparison of open reduction volar locking plate fixation and closed reduction percutaneous K-wire fixation in the treatment of AO type C1 distal radius fractures
    Yetkin, Huseyin
    Altay, Taskin
    Ozan, Firat
    Kayali, Cemil
    Koyuncu, Semmi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (01): : 1139 - 1144
  • [4] Volar locking plate versus K-wire-supported external fixation in the treatment of AO/ASIF type C distal radius fractures: A comparison of functional and radiological outcomes
    Duramaz, Altug
    Bilgili, Mustafa Gokhan
    Karaali, Evren
    Bayram, Berhan
    Ziroglu, Nezih
    Kural, Cemal
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2018, 24 (03): : 255 - 262
  • [5] Dorsal and Volar 2.4-mm Locking Plate Fixation for AO Type C3 Dorsally Comminuted Distal Radius Fractures
    Chou, Ying-Chao
    Chen, Alvin Chao-Yu
    Chen, Chun-Ying
    Hsu, Yung-Heng
    Wu, Chi-Chuan
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (06): : 974 - 981
  • [6] estoring Volar Tilt in AO Type C2 Fractures of the istal Radius With Unilateral External Fixation
    Taylor, Kenneth F.
    Gendelberg, David
    Lustik, Michael B.
    Drake, Matthew L.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (07): : 511 - 516
  • [7] Stability of volar locking plate systems for AO type C3 fractures of the distal radius: biomechanical study in a cadaveric model
    Kamei, Shuzo
    Osada, Denju
    Tamai, Kazuya
    Kato, Nakayuki
    Takai, Morimitsu
    Kameda, Masahiro
    Nohara, Yutaka
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2010, 15 (03) : 357 - 364
  • [8] Fine wire versus locking plate fixation of type C pilon fractures
    Nisarg Mehta
    Simon Graham
    Nikhil Lal
    Lauren Wells
    Nikolaos Giotakis
    Selvadurai Nayagam
    Badri Narayan
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 875 - 882
  • [9] Fine wire versus locking plate fixation of type C pilon fractures
    Mehta, Nisarg
    Graham, Simon
    Lal, Nikhil
    Wells, Lauren
    Giotakis, Nikolaos
    Nayagam, Selvadurai
    Narayan, Badri
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (05): : 875 - 882
  • [10] Volar plate fixation of AQ type C2 and C3 distal radius fractures, a single-center study of 55 patients
    Gerald, Gruber
    Karl, Gruber
    Christian, Giessauf
    Heimo, Clar
    Max, Zacherl
    Florentine, Fuerst
    Alexander, Bernhardt G.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (07) : 467 - 472