Determination of progesterone (P4) from bovine serum samples using a microfluidic immunosensor system

被引:41
|
作者
Javier Arevalo, Fernando [1 ]
Alejandro Messina, German [2 ]
Gabriela Molina, Patricia [1 ]
Alicia Zon, Maria [1 ]
Raba, Julio [2 ]
Fernandez, Hector [1 ]
机构
[1] Univ Nacl Rio Cuarto, Dept Quim, Fac Ciencias Exactas Fis Quim & Nat, RA-5800 Rio Cuarto, Argentina
[2] Univ Nacl San Luis, CONICET, Dept Quim, INQUISAL, San Luis, Argentina
关键词
Enzyme immunoassays; Progesterone; Amperometric immunosensor; Glassy carbon electrode; Horseradish peroxidase; Flow injection analysis; ENZYME-IMMUNOASSAY; BIOSENSOR; ELECTRODES; TYROSINASE; DNA;
D O I
10.1016/j.talanta.2009.10.059
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Progesterone (P4) is a steroidal hormone with a vital role in the maintenance of human and animal health. This paper describes the development of an immunosensor coupled to glassy carbon (GC) electrode and integrated to a microfluidic system to quantify P4 from bovine serum samples in a fast and sensitive way The serum samples spiked with a given P4 concentration and a given P4 concentration bound to horseradish peroxide (HPR) were simultaneously added and, therefore, they competed immunologically with sheep monoclonal anti-P4 antibodies that were immobilized at a rotating disk. HRP in the presence of hydrogen peroxide (H2O2) catalyzes the chatecol (H(2)Q) oxidation to benzoquinone (Q). Its reverse electrochemical reduction to H(2)Q can be detected at a GC electrode surface at -0.15 V by chronoamperometric measurements. These current responses are proportional to the enzyme activity and Inversely proportional to the P4 amount present in bovine serum samples. This P4 immunosensor showed a linear working range from 0.5 to 12 5 ng mL(-1). The detection (DL) and quantification (QL) limits were 02 and 0.5 ng mL(-1), respectively The electrochemical immunosensor had a higher sensitivity than the ELISA method using conventional spectrophotometric detections However, both methods allowed us to obtain similar detection limits. The immunosensor allowed us to make up to 100 determinations on different samples without any previous pre-treatment. This behavior proved to be suitable to detect P4 in routine veterinary, clinical, biological, physiological, and analytical assays. (C) 2009 Elsevier B.V All rights reserved.
引用
收藏
页码:1986 / 1992
页数:7
相关论文
共 50 条
  • [1] Comparative analysis of pregnancy-associated glycoproteins (PAG) and progesterone (P4) in bovine serum samples for better reliability in pregnancy detection
    Friedrich, M.
    Niehoff, C-K
    Gauly, M.
    REPRODUCTION IN DOMESTIC ANIMALS, 2011, 46 : 14 - 15
  • [2] Quantitative Determination of Progesterone (P4) in Canine Blood Serum Using an Enzyme-linked Fluorescence Assay
    Brugger, N.
    Otzdorff, C.
    Walter, B.
    Hoffmann, B.
    Braun, J.
    REPRODUCTION IN DOMESTIC ANIMALS, 2011, 46 (05) : 870 - 873
  • [3] The ratio of serum progesterone (P4) to the number of follicles (P4/Follicle) is a more objective parameter for euploidy rate as compared to systemic progesterone
    Ab Ali, K.
    Lawrenz, B.
    Tegedor, A. L.
    Ruiz, F. R.
    El-Damen, A.
    Khatib, I. E.
    Fatemi, H.
    Munck, N. D.
    HUMAN REPRODUCTION, 2021, 36 : 438 - 438
  • [4] The Ratio of Serum Progesterone (P4) to the Number of Follicles (P4/follicle) is a More Objective Parameter for Euploidy Rate as Compared to Systemic Progesterone Levels
    Khaled Ibrahim Abu Ali
    Barbara Lawrenz
    Upma Shanker
    Francisco Ruiz
    Ahmed El-Damen
    Ibrahim ElKhatib
    Human Fatemi
    Neelke De Munck
    Reproductive Sciences, 2023, 30 : 3046 - 3054
  • [5] The Ratio of Serum Progesterone (P4) to the Number of Follicles (P4/follicle) is a More Objective Parameter for Euploidy Rate as Compared to Systemic Progesterone Levels
    Ali, Khaled Ibrahim Abu
    Lawrenz, Barbara
    Shanker, Upma
    Ruiz, Francisco
    El-Damen, Ahmed
    ElKhatib, Ibrahim
    Fatemi, Human
    De Munck, Neelke
    REPRODUCTIVE SCIENCES, 2023, 30 (10) : 3046 - 3054
  • [6] Development of a very sensitive electrochemical immunosensor for the determination of 17β-estradiol in bovine serum samples
    Jimena Monerris, Melisa
    Javier Arevalo, Fernando
    Fernandez, Hector
    Alicia Zon, Maria
    Gabriela Molina, Patricia
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 525 - 531
  • [7] Molecular regulation of progesterone (P4) synthesis within the bovine corpus luteum (CL)
    Rekawiecki, R.
    Kotwica, J.
    REPRODUCTION IN DOMESTIC ANIMALS, 2006, 41 (04) : 356 - 356
  • [8] Bovine embryos and prostaglandins (Pg) induce progesterone (P4) secretion by granulosa cells in vitro
    Pereira, R. M.
    Vasques, M. I.
    Cunha, T. P.
    Marques, C. C.
    Baptista, M. C.
    Horta, A. E. M.
    REPRODUCTION IN DOMESTIC ANIMALS, 2006, 41 (04) : 335 - 335
  • [9] Development of Electroanalytical Methods Using Different Electrodes for the Determination of Progesterone (P4) in Pharmaceutical Formulations and Human, Cow and Goat Milk
    Cruz, Victoria
    Trivino, Juan Jose
    Arancibia, Veronica
    ELECTROANALYSIS, 2023, 35 (03)
  • [10] Ultra sensitive microfluidic immunosensor for determination of clenbuterol in bovine hair samples using electrodeposited gold nanoparticles and magnetic micro particles as bio-affinity platform
    Regiart, Matias
    Fernandez-Baldo, Martin A.
    Spotorno, Viviana G.
    Bertolino, Franco A.
    Raba, Julio
    BIOSENSORS & BIOELECTRONICS, 2013, 41 : 211 - 217