Field Data Accuracy Analysis of Phasor Measurement Unit Application

被引:0
|
作者
Munir, Buyung Sofiarto [1 ]
Trisetyarso, Agung [1 ]
机构
[1] Bina Nusantara Univ, Dept Grad Program Comp Sci, Jakarta, Indonesia
来源
PROCEEDINGS OF 2016 8TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND ELECTRICAL ENGINEERING (ICITEE) | 2016年
关键词
phasor measurement unit; field data accuracy; measuring instruments error;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The existence of the phasor measurement units (PMU) technology provides new approach in understanding the condition of power system compared to the old technology. However, the parameters recorded by the PMU still rely on traditional installed measuring equipment. The measuring equipment has its own level of accuracy which will affect the data credibility for further analysis. Furthermore the accuracy of such data which is obtained from PMU measurement has to be known to be able to use it for future study. In this paper the field data from PMU measurements which is installed in two 500 kV substation facing one another is analyzed and compared with the results from simulation of the system to determine the accuracy of the field data. From the analysis, it can be seen that the field data taken from PMU measurements still have some error caused by the level of accuracy of measuring instruments and measurement systems used.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Traceability of Calibration for Phasor Measurement Unit
    Tang, Y.
    Stenbakken, G. N.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [22] Phasor Measurement Units and Phasor Data Concentrators Data Evaluation
    Manas, Jakub
    Bilik, Petr
    PROCEEDINGS OF THE 12TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2011, 2011, : 460 - 463
  • [23] Calibration of Phasor Measurement Unit at NIST
    Tang, Yi-hua
    Stenbakken, Gerard N.
    Goldstein, Allen
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (06) : 1417 - 1422
  • [24] Magnetic Field Based Phasor Measurement Unit for Power Grid Frequency Monitoring
    Zhang, Yingchen
    Jia, Chunjuan
    Yuan, Zhiyong
    Xia, Tao
    Zhang, Guorui
    Liu, Yilu
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [25] End-to-End Remote Field Testing of Phasor Measurement Units Using Phasor Measurement Unit Performance Analyzer Test Suite
    Qin, Chuan
    Nie, Zhijie
    Banerjee, P.
    Srivastava, Anurag K.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (06) : 7067 - 7076
  • [26] A High Accuracy Phasor Estimation Algorithm for Phasor Measurement Units Calibrator
    Xu S.
    Liu H.
    Bi T.
    Qian C.
    Zhang F.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (02): : 372 - 382
  • [27] A Modular Phasor Measurement Unit Design featuring Open Data Exchange Methods
    Laverty, David M.
    Hastings, John
    Morrow, D. John
    Khan, R.
    Mclaughlin, K.
    Sezer, S.
    2017 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2017,
  • [28] State estimation and observability analysis for phasor measurement unit measured systems
    School of Electrical and Computer Engineering, National Technical University of Athens, 9, Iroon Polytechneiou Street, Zografou 15780 Athens, Greece
    IET Gener. Transm. Distrib., 9 (902-913):
  • [29] Improved Power Quality Monitoring through Phasor Measurement Unit Data Interpretation
    Pertl, Michael
    Marinelli, Mattia
    Bindner, Henrik
    2015 50TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2015,
  • [30] Reliability Analysis of Phasor Measurement Unit Using Hidden Markov Model
    Murthy, Cherukuri
    Mishra, Anvesha
    Ghosh, Debomita
    Roy, Diptendu Sinha
    Mohanta, Dusmanta Kumar
    IEEE SYSTEMS JOURNAL, 2014, 8 (04): : 1293 - 1301