Field Data Accuracy Analysis of Phasor Measurement Unit Application

被引:0
|
作者
Munir, Buyung Sofiarto [1 ]
Trisetyarso, Agung [1 ]
机构
[1] Bina Nusantara Univ, Dept Grad Program Comp Sci, Jakarta, Indonesia
关键词
phasor measurement unit; field data accuracy; measuring instruments error;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The existence of the phasor measurement units (PMU) technology provides new approach in understanding the condition of power system compared to the old technology. However, the parameters recorded by the PMU still rely on traditional installed measuring equipment. The measuring equipment has its own level of accuracy which will affect the data credibility for further analysis. Furthermore the accuracy of such data which is obtained from PMU measurement has to be known to be able to use it for future study. In this paper the field data from PMU measurements which is installed in two 500 kV substation facing one another is analyzed and compared with the results from simulation of the system to determine the accuracy of the field data. From the analysis, it can be seen that the field data taken from PMU measurements still have some error caused by the level of accuracy of measuring instruments and measurement systems used.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation
    Arendarski, Bartlomiej
    Rabe, Steffen
    Heineken, Wolfram
    Komarnicki, Przemyslaw
    ARCHIVES OF ELECTRICAL ENGINEERING, 2018, 67 (03) : 529 - 543
  • [2] Reliability Analysis of Phasor Measurement Unit Considering Data Uncertainty
    Wang, Yang
    Li, Wenyuan
    Zhang, Peng
    Wang, Bing
    Lu, Jiping
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2012, 27 (03) : 1503 - 1510
  • [3] Application of Phasor & Frequency Estimation Techniques in Phasor Measurement Unit
    MansiVats
    Kamboj, Sangeeta
    2016 7TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2016,
  • [4] Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator
    Diakos, Konstantinos
    Wu, Qiuwei
    Nielsen, Arne Hejde
    2014 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (IEEE PES APPEEC), 2014,
  • [5] Voltage Stability Analysis using Phasor Measurement Unit
    Chouhan, Dolly
    Kapumpa, Kasongo Hyacinthe
    Jaiswal, Varsha
    2017 RECENT DEVELOPMENTS IN CONTROL, AUTOMATION AND POWER ENGINEERING (RDCAPE), 2017, : 147 - 152
  • [6] Towards an Improved Phasor Measurement Unit Data Communications Framework
    Hastings, John
    Laverty, David
    Morrow, D. John
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [7] SYNCHRONISED PHASOR MEASUREMENT UNIT
    Krishna, Vipin R.
    Ashok, S.
    Krishnan, Megha G.
    2014 INTERNATIONAL CONFERENCE ON POWER SIGNALS CONTROL AND COMPUTATIONS (EPSCICON), 2014,
  • [8] Soft Phasor Measurement Unit
    Anisha, N. P.
    Vadana, Prasanna . D.
    Suyampulingam, A.
    SMART GRID TECHNOLOGIES (ICSGT- 2015), 2015, 21 : 533 - 539
  • [9] A Realization of Measurement Unit for Phasor Measurement Unit Based on DSP
    Du, Liang
    Huang, Jin-kai
    Liu, Qun-ying
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [10] Modified Application of Phasor Measurement Unit in Voltage Monitoring of Power System
    Alzahawi, Tara