Thermal Stress Analysis of 600MW Steam Turbine Rotor in Different Governing Modes

被引:0
|
作者
Li, Yong [1 ]
Sun, Haoran [1 ]
Nie, Yuhuo [2 ]
机构
[1] Northeast Dianli Univ, Sch Energy Resources & Mech Engn, Jilin, Peoples R China
[2] PetrolChina Tarim Oilfield Petrochem Co, Kurle City, Peoples R China
关键词
steam turbine; governing modes; governing stage; thermal stress;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
At present, there are still some imported steam turbines which are originally designed to operate in throttling governing, which leads to the low efficiency when the steam turbine is working with part load. In order to enhance economical performance of steam turbine, it has to be transformed into nozzle governing. After changing throttling governing to nozzle governing for the steam turbine, the temperature variation of the front gland seal and stages of high pressure rotor are increased. The higher temperature makes them to be the most dangerous parts and affects the security and the velocity of load change. The computational object is intercepted from hp-ip rotor of the 600MW steam turbine in this paper. The distribution of the temperature and thermal stress in the governing stage and the first stage of high pressure cylinder is calculated two-dimensionally. The changes of the temperature and stress in different governing modes are analyzed. The result of calculation provides a reliable basis for on-line monitoring of the rotor thermal stress, which ensures the security and economical operation of steam turbine units.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Correlation dimension in fault diagnosis of 600 MW steam turbine generator
    Yao, Bao-Heng
    Yang, Xia-Ju
    Tong, De-Chun
    Chen, Zhao-Neng
    Journal of Dong Hua University (English Edition), 2005, 22 (01): : 31 - 36
  • [42] Numerical evaluation of the life consume in a 75 MW steam turbine rotor
    Carnero, A
    Garcia, R
    Kubiak, J
    Urquiza, G
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59 - PTS I AND II, 1997, 59 : 611 - 617
  • [43] Correlation Dimension in Fault Diagnosis of 600 MW Steam Turbine Generator
    姚宝恒
    杨霞菊
    佟德纯
    陈兆能
    Journal of Donghua University(English Edition), 2005, (01) : 31 - 36
  • [44] Crack cause analysis of pulverizing wheel in fan mill of 600 MW steam turbine unit
    Liu, Chao
    Jiang, Dongxiang
    Chu, Fulei
    Chen, Jingming
    ENGINEERING FAILURE ANALYSIS, 2014, 42 : 60 - 73
  • [45] Analysis of the effect on steam turbine rotor of load variation for Cogeneration Steam Turbine
    Song, Zheming
    Su, Yongsheng
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 1603 - 1607
  • [46] Numerical evaluation of the life consume in a 75 MW steam turbine rotor
    Carnero, A
    Garcia, R
    Kubiak, J
    Urquiza, G
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59, I AND II, 1997, 59 : 611 - 617
  • [47] STRESS CORROSION CRACKING AND CORROSION FATIGUE ANALYSIS OF NUCLEAR STEAM TURBINE ROTOR
    Chen, Gang
    Jiang, Puning
    Ye, Xingzhu
    Zhang, Junhui
    Hu, Yifeng
    Hao, Zhenzhen
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 1B, 2014,
  • [48] The Research on the Key Factor Affect the Precision in Stress Analysis for the Rotor of Steam Turbine
    Zhang, Chunlin
    Hu, Niansu
    Yang, Wen
    Wang, Jianmei
    Li, Min
    Ma, Cheng
    APPLIED MECHANICS AND MATERIALS I, PTS 1-3, 2013, 275-277 : 83 - +
  • [49] THERMAL TESTS ON 300 MW STEAM TURBINE CONDENSERS
    KONOVALO.GM
    KIRSH, AK
    YEGOROV, VN
    KANAEV, VD
    THERMAL ENGINEERING, 1970, 17 (09) : 59 - &
  • [50] Failure analysis of steam turbine rotor disk
    Batra U.
    Journal of Failure Analysis and Prevention, 2010, 10 (03) : 178 - 182