Chest CT Performed with 3D and z-Axis Automatic Tube Current Modulation Technique: Breast and Effective Doses

被引:8
|
作者
Matsubara, Kosuke [1 ]
Takata, Tadanori [2 ]
Koshida, Kichiro [1 ]
Noto, Kimiya [2 ]
Shimono, Tetsunori [3 ]
Horii, Junsei [2 ]
Yamamoto, Tomoyuki [2 ]
Matsui, Osamu [4 ]
机构
[1] Kanazawa Univ, Dept Quantum Med Technol, Fac Hlth Sci, Kanazawa, Ishikawa 9200942, Japan
[2] Kanazawa Univ Hosp, Dept Radiol Technol, Kanazawa, Ishikawa, Japan
[3] Hoshigaoka Koseinenkin Hosp, Dept Radiol, Hirakata, Osaka, Japan
[4] Kanazawa Univ, Dept Radiol, Fac Med, Kanazawa, Ishikawa 9200942, Japan
关键词
Computed tomography; chests; mammary gland; absorbed dose; effective dose; MULTIDETECTOR-ROW CT; OPTIMIZATION;
D O I
10.1016/j.acra.2008.11.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Chest computed tomographic (CT) scans are the most effective examinations for detecting lung cancer at ail early stage. In chest CT examinations. it is important to consider the reduction of radiation (lose. particularly to the mammary gland. The objective of this study was to assess breast doses and effective doses oil chest CT examinations between three-dimensional and z-axis automatic tube current modulation (ATCM) techniques. Materials and Methods. Absorbed close to the breast, lung. mediastinum, and skin was evaluated with ail anthropomorphic phantom and radiophotoluminescence glass dosimeters using two different CT scanners. The dosimeters were placed inside and outside the phantom. The phantom was scanned using three-dimensional and z-axis ATCM techniques after scanning localizer radiographs from the horizontal and vertical directions. After scanning, each or-an dose was calculated. Moreover, file dose-length product recorded in the dose reports was examined, and each effective dose was calculated. Results. Compared with z-axis ATCM, three-dimensional ATCM reduced breast dose by 0.7% to 18.6% and effective dose by 4.9% to 10.2%. In particular, three-dimensional ATCM reduced frontal breast dose. For other organs, three-dimensional ATCM reduced absorbed closes by 3.4% to 13.6% compared to Z-axis ATCM. Conclusion. Three-dimensional ATCM call reduce absorbed closes to the breast and other organs, in addition to reducing effective dose, compared to z-axis ATCM.
引用
收藏
页码:450 / 455
页数:6
相关论文
共 50 条
  • [1] Comparison between 3-D and z-axis automatic tube current modulation technique in multidetector-row CT
    Matsubara, K.
    Koshida, K.
    Suzuki, M.
    Tsujii, H.
    Yamamoto, T.
    Matsui, O.
    RADIATION PROTECTION DOSIMETRY, 2008, 128 (01) : 106 - 111
  • [2] Comparison of z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis
    Kalra, MK
    Maher, MM
    Toth, TL
    Kamath, RS
    Halpern, EF
    Saini, S
    RADIOLOGY, 2004, 232 (02) : 347 - 353
  • [3] Chest CT performed with z-axis modulation: Scanning protocol and radiation dose
    Kalra, MK
    Rizzo, S
    Maher, MM
    Halpern, EF
    Toth, TL
    Shepard, JAO
    Aquino, SL
    RADIOLOGY, 2005, 237 (01) : 303 - 308
  • [4] Quantitative assessment of image noise and streak artifact on CT image: Comparison of z-axis automatic tube current modulation technique with fixed tube current technique
    Imai, Kuniharu
    Ikeda, Mitsuru
    Enchi, Yukihiro
    Niimi, Takanaga
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2009, 33 (05) : 353 - 358
  • [5] Thyroid Shields versus z-Axis Automatic Tube Current Modulation for Dose Reduction at Neck CT
    Leswick, David A.
    Hunt, Megan M.
    Webster, Steven T.
    Fladeland, Derek A.
    RADIOLOGY, 2008, 249 (02) : 572 - 580
  • [6] Detection of urinary tract stones at low-radiation-dose CT with Z-axis automatic tube current modulation: Phantom and clinical studies
    Kalra, MK
    Maher, MM
    D'Souza, RV
    Rizzo, S
    Halpern, EF
    Blake, MA
    Saini, S
    RADIOLOGY, 2005, 235 (02) : 523 - 529
  • [7] Automatic tube current modulation technique for multidetector CT: is it effective with a 64-detector CT?
    Funama Y.
    Awai K.
    Hatemura M.
    Shimamura M.
    Yanaga Y.
    Oda S.
    Yamashita Y.
    Radiological Physics and Technology, 2008, 1 (1) : 33 - 37
  • [8] Evaluating Effective Doses and Image Quality for Multislice CT Using Automatic Tube Current Modulation
    Tsai, S. F.
    Tsai, H. Y.
    Tyan, Y. S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [9] Sixteen-detector row CT of abdomen and pelvis: Study for optimization of Z-axis modulation technique performed in 153 patients
    Kalra, MK
    Maher, MM
    Kamath, RS
    Horiuchi, T
    Toth, TL
    Halpern, EF
    Saini, S
    RADIOLOGY, 2004, 233 (01) : 241 - 249
  • [10] A comparison of breast and lung doses from chest CT scans using organ-based tube current modulation (OBTCM) vs. Automatic tube current modulation (ATCM)
    Layman, Rick R.
    Hardy, Anthony J.
    Kim, Hyun J.
    Chou, Ei Ne
    Bostani, Maryam
    Cagnon, Chris
    Cody, Dianna
    McNitt-Gray, Michael
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (05): : 97 - 109