Diagnosing Neonatal Aortic Coarctation in the Setting of Patent Ductus Arteriosus

被引:11
|
作者
Peng, David M.
Punn, Rajesh
Maeda, Katsuhide
Tierney, Elif Seda Selamet [1 ,2 ]
机构
[1] Stanford Univ, Lucile Packard Childrens Hosp, Div Pediat Cardiol, 725 Welch Rd,Ste 120, Palo Alto, CA 94304 USA
[2] Stanford Univ, Dept Pediat, 725 Welch Rd,Ste 120, Palo Alto, CA 94304 USA
来源
ANNALS OF THORACIC SURGERY | 2016年 / 101卷 / 03期
关键词
CONGENITAL HEART-DISEASE; NONINVASIVE DIAGNOSIS; PREVALENCE; VOLUME;
D O I
10.1016/j.athoracsur.2015.09.050
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. In neonates, it is challenging to diagnose aortic coarctation in the setting of a patent ductus arteriosus (PDA). Frequently, serial echocardiograms are performed, and diagnosis is delayed until the PDA closes. The purpose of this study was to identify echocardiographic predictors of neonatal coarctation in the presence of a PDA in cases in which diagnosis is uncertain. Methods. We retrospectively identified neonates diagnosed with possible but not definitive coarctation in the presence of a PDA by echocardiography (January 2004 through August 2013). The carotid-subclavian artery index (CSAi) was defined as the distal transverse arch diameter divided by the distance between the left common carotid and left subclavian arteries. Medical records were reviewed to identify patients who underwent coarctation repair within 1 year. A separate validation group was identified with the same methodology (September 2013 through April 2015). Results. Thirty-three patients were identified (median age 1, range 0-8 days). Twelve patients (36%) underwent coarctation repair. The coarctation group had smaller aortic and mitral valves, distal transverse arch, and isthmus z scores, larger right innominate artery, and longer transverse arch compared with the remaining group (p < 0.05). The CSAi was lower in the coarctation group (p = 0.014), and a cutoff of less than 0.85 yielded a sensitivity of 0.83 and specificity of 0.86 for coarctation (area under the receiver operating characteristic curve, 0.91). In the validation group (n = 12; median follow-up, 316 days), none of the 8 patients with a CSAi of greater than 0.85 have required surgery. The intraclass correlation coefficient for CSAi was 0.79 (95% confidence interval, 0.18 to 0.95). Conclusions. The CSAi, a simple and reproducible measure, can identify neonates at risk for aortic coarctation even in the presence of a PDA, prevent multiple echocardiographic evaluations, and hence guide appropriate resource utilization. (C) 2016 by The Society of Thoracic Surgeons
引用
收藏
页码:1005 / 1011
页数:8
相关论文
共 50 条
  • [21] Simultaneous Treatment of Native Aortic Coarctation Combined With Patent Ductus Arteriosus Using a Covered Stent
    Meng Zili
    Guo, Xi
    Wu, Shucai
    Li, Hui
    Huo, Hongwei
    Liu, Yonghui
    Wang, Xinju
    Meng, Zili
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C193 - C193
  • [22] Congenital absence of right pulmonary artery associated with left patent ductus arteriosus and aortic coarctation
    He Lan
    Liu Fang
    Huang Guo-ying
    CHINESE MEDICAL JOURNAL, 2013, 126 (16) : 3192 - 3192
  • [23] Aortic dissection with extension to a patent ductus arteriosus
    Festic, E
    Steiner, RM
    Spatz, E
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (04): : 459 - 462
  • [24] Aortic dissection with extension to a patent ductus arteriosus
    Emir Festic
    Robert M. Steiner
    Eileen Spatz
    The International Journal of Cardiovascular Imaging, 2005, 21 : 459 - 462
  • [25] Quadricuspid Aortic Valve with Patent Ductus Arteriosus
    Seol, Sang-Hoon
    Kim, Ung
    Cho, Hwan-Jin
    Kim, Dong-Kie
    Kim, Doo-Il
    Kim, Dong-Soo
    TEXAS HEART INSTITUTE JOURNAL, 2010, 37 (06): : 726 - 727
  • [26] PATENT DUCTUS ARTERIOSUS WITH AN ABNORMAL AORTIC VALVE
    BONHAMCARTER, RE
    WALKER, CHM
    DALEY, R
    MATTHEWS, MB
    MEDD, WE
    BRITISH HEART JOURNAL, 1955, 17 (02): : 255 - 261
  • [27] SURGICAL MANAGEMENT OF PATENT DUCTUS ARTERIOSUS ASSOCIATED WITH COARCTATION OF THE AORTA
    DONG, E
    LOWER, RR
    HURLEY, EJ
    SHUMWAY, NE
    AMERICAN JOURNAL OF SURGERY, 1962, 103 (02): : 255 - 261
  • [28] COARCTATION OF THE AORTA WITH PATENT DUCTUS ARTERIOSUS AND MULTIPLE INTRACARDIAC DEFECTS
    ROSSALL, RE
    SHIEL, FOM
    SHOESMITH, J
    AMERICAN JOURNAL OF CARDIOLOGY, 1958, 2 (04): : 502 - 506
  • [29] APPLICATION OF MICROPLETHYSMOGRAPHY TO THE DIAGNOSIS OF PATENT DUCTUS ARTERIOSUS AND COARCTATION OF THE AORTA
    MEGIBOW, RS
    FEITELBERG, S
    AMERICAN JOURNAL OF MEDICINE, 1948, 4 (06): : 798 - 805
  • [30] AORTIC FLOW KINETICS IN PATENT DUCTUS ARTERIOSUS
    LIN, C
    REPLOGLE, R
    CASSELS, D
    ARCILLA, R
    CIRCULATION, 1971, 44 (04) : 193 - &