Utility of Delayed Whole-Body Bone Scintigraphy After Directed Three-Phase Scintigraphy

被引:6
|
作者
Davenport, Matthew S. [1 ]
Brown, Richard K. J. [1 ]
Frey, Kirk A. [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
bone scintigraphy; cost-effectiveness; incidental findings; radiologist recommendations; three-phase bone scan; REFLEX SYMPATHETIC DYSTROPHY; CONCISE COMMUNICATION; OSTEOMYELITIS; DIAGNOSIS; SCAN; SACROILIITIS; RADIOGRAPHY; PROSTHESIS; INFECTION; FOOT;
D O I
10.2214/AJR.08.2142
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine the diagnostic yield and clinical importance of delayed whole-body bone scintigraphy in directed three-phase examinations. MATERIALS AND METHODS. The records of 400 consecutively registered patients who underwent combined three-phase and delayed whole-body Tc-99m-methylene diphosphonate bone scintigraphy for a variety of indications were reviewed. Clinical indications, findings, recommendations, and outcome were assessed. RESULTS. Three-phase bone scintigraphy was performed on 156 men and boys and 244 women and girls (61%). Fifty-two patients (13%) were 17 years old or younger, and 236 patients (59%) were older than 40 years. The mean increase in study duration due to whole-body imaging was 25 minutes (range, 21-31 minutes). Excluding the three-phase area of interest, the whole-body examination had a normal tracer distribution in 131 examinations (33%), showed solely degenerative changes in 103 (26%), and showed findings unrelated to the area of interest in 166 patients (41%). In no case did the findings outside the area of interest alter the diagnosis or diagnostic certainty in the three-phase study, but those findings did generate 82 recommendations for additional diagnostic investigation. As a direct result of the recommendations, clinicians requested 18 radiographic, two CT, one MRI, and one ultrasound examinations, one additional bone scan, and two referrals to a consultant. Recommendations based on findings outside the three-phase area of interest affected treatment in one case: Temporomandibular joint uptake resulted in a referral for physical therapy. CONCLUSION. For most indications, delayed whole-body imaging after directed three-phase bone scintigraphy does not improve diagnostic yield, does not alter patient care, and may be an unnecessary use of medical resources.
引用
收藏
页码:338 / 342
页数:5
相关论文
共 50 条
  • [11] Aortic dissection detected on three-phase bone scintigraphy
    Yen, RF
    Pan, MH
    Tsai, YC
    Wu, YW
    CLINICAL NUCLEAR MEDICINE, 2003, 28 (10) : 858 - 860
  • [12] Three-Phase Bone Scintigraphy for Imaging Osteoradionecrosis of the Jaw
    Lapa, Constantin
    Linz, Christian
    Bluemel, Christina
    Mottok, Anja
    Mueller-Richter, Urs
    Kuebler, Alexander
    Schneider, Peter
    Czernin, Johannes
    Buck, Andreas K.
    Herrmann, Ken
    CLINICAL NUCLEAR MEDICINE, 2014, 39 (01) : 21 - 25
  • [13] Whole body bone scintigraphy after parachute accident
    Pichler, R
    Krieglsteiner, S
    Wurm, G
    Adelwöhrer, C
    Fischer, J
    WIENER KLINISCHE WOCHENSCHRIFT, 2005, 117 (04) : 129 - 129
  • [14] Whole-body bone scintigraphy in comparison with bone metabolism in lung cancer patients
    Weissensteiner, J.
    Babusikova, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S667 - S668
  • [15] Comparative study of whole-body MRI and bone scintigraphy for the detection of bone metastases
    Balliu, E.
    Boada, M.
    Pelaez, I.
    Vilanova, J. C.
    Barcelo-Vidal, C.
    Rubio, A.
    Galofre, P.
    Castro, A.
    Pedraza, S.
    CLINICAL RADIOLOGY, 2010, 65 (12) : 989 - 996
  • [16] A multicentre simulation study of planar whole-body bone scintigraphy in Sweden
    Agnetha Gustafsson
    Eva Örndahl
    David Minarik
    Kerstin Cederholm
    Sophia Frantz
    Jessica Hagerman
    Lena Johansson
    Johan Fredén Lindqvist
    Cathrine Jonsson
    EJNMMI Physics, 9
  • [17] A multicentre simulation study of planar whole-body bone scintigraphy in Sweden
    Gustafsson, Agnetha
    Orndahl, Eva
    Minarik, David
    Cederholm, Kerstin
    Frantz, Sophia
    Hagerman, Jessica
    Johansson, Lena
    Lindqvist, Johan Freden
    Jonsson, Cathrine
    EJNMMI PHYSICS, 2022, 9 (01)
  • [18] QUANTITATIVE WHOLE-BODY BONE-SCINTIGRAPHY .1. METHODOLOGY
    ANGER, K
    KIIPER, K
    NUKLEARMEDIZIN, 1980, 19 (02) : 64 - 73
  • [19] Three phase whole body bone scintigraphy in heterotopic ossification with traumatic brain injury
    Berk, F
    Kaya, A
    Dalyan, M
    Çakci, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1043 - 1043
  • [20] Three-phase bone scintigraphy in clinically unsuspected bone injuries in athletes
    Huic, D
    Bojanic, I
    Dodig, D
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1055 - 1055