Novel Stereoselective High-Performance Liquid Chromatographic Method for Simultaneous Determination of Guaifenesin and Ketorolac Enantiomers in Human Plasma

被引:11
|
作者
Maher, Hadir M. [1 ,2 ]
Al-Taweel, Shorog M. [1 ]
Alshehri, Mona M. [1 ]
Alzoman, Nourah Z. [1 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11495, Saudi Arabia
[2] Univ Alexandria, Fac Pharm, Dept Pharmaceut Analyt Chem, Alexandria, Egypt
关键词
chiral separation; amylose chiral selector; guaifenesin; ketorolac; human plasma; SEPARATION STRATEGY; CHIRAL SEPARATION; ANALGESIC POTENCY; STATIONARY PHASES; PARACETAMOL; HPLC; DRUGS; ENANTIOSEPARATION; PHARMACOKINETICS; MICROEXTRACTION;
D O I
10.1002/chir.22354
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A novel method was developed for the simultaneous determination of guaifenesin (GUA) and ketorolac tromethamine (KET) enantiomers in plasma samples. Since GUA probably increases the absorption of coadministered drugs (e. g., KET), it would be extremely important to monitor KET plasma levels for the purpose of dose adjustment with a subsequent decrease in the side effects. Enantiomeric resolution was achieved on a polysaccharide-based chiral stationary phase, amylose-2, as a chiral selector under the normal phase (NP) mode and using ornidazole (ORN) as internal standard. This innovative method has the advantage of the ease and reliability of sample preparation for plasma samples. Sample clean-up was based on simply using methanol for protein precipitation followed by direct extraction of drug residues using ethanol. Both GUA and KET enantiomers were separated using an isocratic mobile phase composed of hexane/isopropanol/trifluoroacetic acid, 85: 15: 0.05 v/v/v. Peak area ratios were linear over the range 0.05-20 mu g/mL for the four enantiomers S (+) GUA, R (-) GUA, R (+) KET, and S (-) KET. The method was fully validated according to the International Conference on Harmonization (ICH) guidelines in terms of system suitability, specificity, accuracy, precision, robustness, and solution stability. Finally, this procedure was innovative to apply the rationale of developing a chiral high-performance liquid chromatography (HPLC) procedure for the simultaneous quantitative analysis of drug isomers in clinical samples. (C) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:629 / 639
页数:11
相关论文
共 50 条
  • [41] High-performance liquid chromatographic determination of baclofen in human plasma
    Millerioux, L
    Brault, M
    Gualano, V
    Mignot, A
    JOURNAL OF CHROMATOGRAPHY A, 1996, 729 (1-2) : 309 - 314
  • [42] High-performance liquid chromatographic determination of granisetron in human plasma
    Pinguet, F
    Bressolle, F
    Martel, P
    Salabert, D
    Astre, C
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 675 (01): : 99 - 105
  • [43] High-performance liquid chromatographic determination of tramadol in human plasma
    Nobilis, M
    Pastera, J
    Anzenbacher, P
    Svoboda, D
    Kopecky, J
    Perlik, F
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 681 (01): : 177 - 183
  • [44] Determination of fexofenadine enantiomers in human plasma with high-performance liquid chromatography
    Miura, Masatomo
    Uno, Tsukasa
    Tateishi, Tomonori
    Suzuki, Toshio
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (02) : 741 - 745
  • [45] High-performance liquid chromatographic method for simultaneous determination of hawthorn active components in rat plasma
    Chang, Q
    Zhu, M
    Zuo, Z
    Chow, M
    Ho, WKK
    JOURNAL OF CHROMATOGRAPHY B, 2001, 760 (02): : 227 - 235
  • [46] A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR ROUTINE SIMULTANEOUS DETERMINATION OF NICOTINE AND COTININE IN PLASMA
    HARIHARAN, M
    VANNOORD, T
    GREDEN, JF
    CLINICAL CHEMISTRY, 1988, 34 (04) : 724 - 729
  • [47] A stereospecific high-performance liquid chromatographic assay for the determination of ketoconazole enantiomers in rat plasma
    Hamdy, Dalia A.
    Brocks, Dion R.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (05) : 542 - 547
  • [48] DEVELOPMENT AND VALIDATION OF A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE QUANTITATION OF WARFARIN ENANTIOMERS IN HUMAN PLASMA
    WENG, ND
    LEE, JW
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (09) : 785 - 792
  • [49] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF PENBUTOLOL ENANTIOMERS IN PLASMA WITH FLUORESCENCE DETECTION
    GOTO, J
    SHAO, G
    ITO, M
    KURIKI, T
    NAMBARA, T
    ANALYTICAL SCIENCES, 1991, 7 (05) : 723 - 726
  • [50] SIMULTANEOUS HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF DAPSONE AND MONOACETYLDAPSONE IN HUMAN PLASMA AND URINE
    ABUIRJEIE, MA
    IRSHAID, YM
    ALHADIDI, HF
    RAWASHDEH, NM
    JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 1991, 16 (04) : 247 - 255