Low gas flow inductively coupled plasma optical emission spectrometry for the analysis of food samples after microwave digestion

被引:10
|
作者
Nowak, Sascha [1 ]
Gesell, Monika [2 ]
Holtkamp, Michael [1 ]
Scheffer, Andy [1 ]
Sperling, Michael [1 ,3 ]
Karst, Uwe [1 ]
Buscher, Wolfgang [1 ]
机构
[1] Univ Munster, Inst Inorgan & Analyt Chem, D-48149 Munster, Germany
[2] Univ Munster, Inst Food Chem, D-48149 Munster, Germany
[3] European Virtual Inst Speciat Anal, D-48149 Munster, Germany
关键词
Inductively coupled plasma (ICP); Optical emission spectroscopy (OES); Static high sensitivity ICP (SHIP); Microwave digestion; Low gas flow; Fish samples; Honey samples; Trace metals; PRESSURE ICP TORCH; CONSUMPTION; DESIGN; SHIP;
D O I
10.1016/j.talanta.2014.06.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, the recently introduced low flow inductively coupled plasma optical emission spectrometry (ICP-OES) with a total argon consumption below 0.7 L/min is applied for the first time to the field of food analysis. One goal is the investigation of the performance of this low flow plasma compared to a conventional ICP-OES system when non-aqueous samples with a certain matrix are introduced into the system. For this purpose, arsenic is determined in three different kinds of fish samples. In addition several nutrients (K, Na, Mg, Ca) and trace metals (Co, Cu, Mn, Cd, Pb, Zn, Fe, and Ni) are determined in honey samples (acacia) after microwave digestion. The precision of the measurements is characterized by relative standard deviations (RSD) and compared to the corresponding precision values achieved using the conventional Fassel-type torch of the ICP. To prove the accuracy of the low flow ICP-OES method, the obtained data from honey samples are validated by a conventional ICP-OES. For the measurements concerning arsenic in fish, the low flow ICP-OES values are validated by conventional Fassel-type ICP-OES. Furthermore, a certified reference material was investigated with the low gas flow setup. Limits of detection (LOD), according to the 3 sigma criterion, were determined to be in the low microgram per liter range for all analytes. Recovery rates in the range of 96-106% were observed for the determined trace metal elements. It was proven that the low gas flow ICP-OES leads to results that are comparable with those obtained with the Fassel-type torch for the analysis of food samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:575 / 578
页数:4
相关论文
共 50 条
  • [1] Analysis of whole blood samples with low gas flow inductively coupled plasma-optical emission spectrometry
    Nowak, Sascha
    Kuennemeyer, Jens
    Terborg, Lydia
    Truempler, Stefan
    Guensel, Andreas
    Wiesmueller, Gerhard A.
    Karst, Uwe
    Buscher, Wolfgang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (03) : 1023 - 1026
  • [2] Analysis of whole blood samples with low gas flow inductively coupled plasma-optical emission spectrometry
    Sascha Nowak
    Jens Künnemeyer
    Lydia Terborg
    Stefan Trümpler
    Andreas Günsel
    Gerhard A. Wiesmüller
    Uwe Karst
    Wolfgang Buscher
    Analytical and Bioanalytical Chemistry, 2015, 407 : 1023 - 1026
  • [3] Multi-element analysis of food by microwave digestion and inductively coupled plasma-atomic emission spectrometry
    Dolan, SP
    Capar, SG
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2002, 15 (05) : 593 - 615
  • [4] Microwave digestion of sludge, soil and sediment samples for metal analysis by inductively coupled plasma-atomic emission spectrometry
    Sandroni, V
    Smith, CMM
    ANALYTICA CHIMICA ACTA, 2002, 468 (02) : 335 - 344
  • [5] Determination of silver in nano-plastic food packaging by microwave digestion coupled with inductively coupled plasma atomic emission spectrometry or inductively coupled plasma mass spectrometry
    Lin, Q. -B.
    Li, B.
    Song, H.
    Wu, H. -J.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (08): : 1123 - 1128
  • [6] Digestion Procedures for the Elemental Analysis of Wood by Inductively Coupled Plasma Optical Emission Spectrometry
    Tafur-Marinos, Janeth A.
    Ginepro, Marco
    Pastero, Linda
    Zelano, Vincenzo
    ANALYTICAL LETTERS, 2016, 49 (11) : 1722 - 1733
  • [7] Analysis of doped luminescent lanthanide fluoride nanoparticles by low gas flow inductively coupled plasma optical emission spectrometry
    Engelhard, Carsten
    Vielhaber, Torsten
    Scheffer, Andy
    Brocksieper, Mareike
    Buscher, Wolfgang
    Karst, Uwe
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (03) : 407 - 411
  • [8] Plasma diagnostic on a low-flow plasma for inductively coupled plasma optical emission spectrometry
    Engelhard, Carsten
    Chan, George C. -Y.
    Gamez, Gerardo
    Buscher, Wolfgang
    Hieftje, Gary M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (06) : 619 - 629
  • [9] Metal elements analysis of fruits using inductively coupled plasma atomic emission spectrometry coupled with microwave digestion
    Yang, Li
    Liu, Yongtao
    Zhang, Jianwei
    Gao, Yingying
    Xi, Guoxi
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2013, 90 (09) : 1467 - 1471
  • [10] Determination of trace elements in edible fungi by axially view inductively coupled plasma optical emission spectrometry after microwave digestion
    Yan, Qinghua
    Yang, Li
    Wang, Ge
    Wang, Qing
    Zhang, Jianwei
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2013, 90 (03) : 393 - 397