LCD display screen performance testing for handheld thermal imaging cameras

被引:0
|
作者
Dinaburg, Joshua B. [1 ]
Amon, Francine [1 ]
Hamins, Anthony [1 ]
Boynton, Paul [1 ]
机构
[1] Natl Inst Stand & Technol, 100 Bur Dr, Gaithersburg, MD 20899 USA
来源
INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING XVII | 2006年 / 6207卷
关键词
characterization; thermal imager; display performance; performance metrics; non-destructive testing; infrared camera; TIC;
D O I
10.1117/12.666280
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Handheld thermal imaging cameras are an important tool for the first responder community. As their use becomes more prevalent, it will become important for a set of standard test metrics to be available to characterize the performance of these cameras. A major factor in the performance of the imagers is the quality of the image on a display screen. An imager may employ any type of display screen, but the results of this paper will focus on those using liquid crystal displays. First responders, especially firefighters, in the field rely on the performance of this screen to relay vital information during critical situations. Current research on thermal imaging camera performance metrics for first responder applications uses trained observer tests or camera composite output signal measurements. Trained observer tests are subjective and composite output tests do not evaluate the performance of the complete imaging system. It is the goal of this work to develop a nondestructive, objective method that tests the performance of the entire thermal imaging camera system, from the infrared sensor to the display screen. Application of existing display screen performance metrics to thermal imaging cameras requires additional consideration. Most display screen test metrics require a well defined electronic input, with either full black or white pixel input, often encompassing detailed spatial patterns and resolution. Well characterized thermal inputs must be used to obtain accurate, repeatable, and non-destructive display screen measurements for infrared cameras. For this work, a thermal target is used to correlate the measured camera output with the actual display luminance. A test method was developed to determine display screen luminance. A well characterized CCD camera and digital recording device were used to determine an electro-optical transfer function for thermal imaging cameras. This value directly relates the composite output signal to the luminance of the display screen, providing a realistic characterization of system performance.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Handheld thermal imaging for law enforcement and counterdrug applications
    Haran, TL
    Higgins, MK
    Thomas, ML
    SENSORS, AND COMMAND, CONTROL, COMMUNICATIONS, AND INTELLIGENCE(C31) TECHNOLOGIES FOR HOMELAND SECURITY AND HOMELAND DEFENSE III, PTS 1 AND 2, 2004, 5403 : 831 - 841
  • [42] Assessing the Performance of Handheld Glucose Testing for Critical Care
    Kost, Gerald J.
    Tran, Nam K.
    Louie, Richard F.
    Gentile, Nicole L.
    Abad, Victor J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 (06) : 445 - 451
  • [44] Performance of liquid-crystal displays for fire-service thermal-imaging cameras
    Dinaburg, Joshua B.
    Amon, Francine
    Hamins, Anthony
    Boynton, Paul
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2008, 16 (06) : 703 - 709
  • [45] Using a Combination of Aerial Infrared and Handheld Infrared Cameras for Measuring, Analyzing, and Prioritizing the Optimal Solutions for the Thermal Performance of "Big Box" Buildings
    Stockton, Gregory R.
    Lucas, R. Gillem
    THERMOSENSE: THERMAL INFRARED APPLICATIONS XXXIII, 2011, 8013
  • [46] MulDiRoH: A Multi-View Display Using a QDA Screen with Multiple Cameras for Human Representation
    Ozawa, Shiro
    Mieda, Satoshi
    Yao, Yasuhiro
    Kawakami, Tohru
    Nasu, Senshi
    Ishinabe, Takahiro
    Kano, Mitsuru
    Sasai, Mutsumi
    Suzuki, Yoshito
    Uchida, Tatsuo
    2012 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2012,
  • [47] PERFORMANCE TESTING OF SUBMERGED INTAKE SCREEN
    ODGAARD, AJ
    KENNEDY, JF
    DUSOLD, EH
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1984, 110 (10): : 1484 - 1489
  • [48] Improving ROI detection in photoplethysmographic imaging with thermal cameras
    Scebba, Gaetano
    Dragas, Jelena
    Hu, Suyi
    Karlen, Walter
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 4285 - 4288
  • [49] Measurement of the nonuniformity of first responder thermal imaging cameras
    Lock, Andrew
    Amon, Francine
    INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING XIX, 2008, 6941
  • [50] Using Thermal Imaging Cameras to Test Electronical Systems
    Gyorok, Gyorgy
    Beszedes, Bertalan
    2018 IEEE INTERNATIONAL CONFERENCE AND WORKSHOP IN OBUDA ON ELECTRICAL AND POWER ENGINEERING (CANDO-EPE), 2018, : 147 - 151