Error minimization in high-accuracy scanning deflectometry

被引:4
|
作者
Geckeler, Ralf D. [1 ]
机构
[1] PTB, D-38116 Braunschweig, Germany
来源
关键词
deflectometry; flatness standard; traceability; autocollimator; dimensional metrology; transfer function;
D O I
10.1117/12.679339
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A number of deflectometric devices have been developed and built for measuring optical surfaces for industrial and research applications. These include the scanning facility for the highly accurate and traceable measurement of large near-flat and slightly curved optical surfaces at PTB which is based on the Extended Shear Angle Difference (ESAD) deflectometry technique. ESAD combines deflectometric and shearing techniques in a unique way to enable error minimization and traceability. With this facility, sub-nm repeatability, reproducibility, and uncertainty of topography measurement have been achieved. A central optical element of the ESAD device and of several other deflectometric scanning systems is a pentagon prism which is used to deflect the light beam of an angle measuring device by 90 degrees. With ESAD, the pentagon prism is used to provide the lateral displacement of the measuring beam on the surface of the specimen to perform the shearing (angle difference) measurements, while other deflectometric systems make use of the pentagon prisms to scan the surface under test directly. It will be reported on the ESAD device using optimized opto-mechanical components, and on measurement results. Information on the adjustment of the pentagon prism, the specimen under test, and the axes of the autocollimator which has been achieved with the ESAD device will be presented. It will be reported on the reduction of the systematic errors in the angle difference measurement down to the milliarcsec level. Measurement comparisons involving ESAD deflectometry, an independent deflectometric scanning system, Fizeau interferometry using a mercury mirror, and absolute interferometry applying the skip flat method will be presented. Information on the autocollimator used as an angle measuring device and its calibration will be provided.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] High-accuracy critical-dimension metrology using a scanning electron microscope
    Lowney, JR
    Vladar, AE
    Postek, MT
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY X, 1996, 2725 : 515 - 526
  • [22] High-accuracy laser spatial alignment and stabilization system with error separation technology
    Ma C.
    Tang M.
    Sun Q.
    Sun Q.
    Ding C.
    Kuang C.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2023, 31 (11): : 1607 - 1618
  • [23] High-accuracy experimental analysis and correction of blade tip timing measurement error
    Meng, Yiming
    Xiao, Zhicheng
    Ouyang, Hua
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2024, 39 (07):
  • [25] High-accuracy principal-angle scanning spectroscopic ellipsometry of semiconductor interfaces
    Nguyen, NV
    ChandlerHorowitz, D
    Pellegrino, JG
    Amirtharaj, PM
    SEMICONDUCTOR CHARACTERIZATION: PRESENT STATUS AND FUTURE NEEDS, 1996, : 438 - 442
  • [26] High-accuracy method of refraction error correction based on the velocity of monopulse radar
    Zhang, Yu
    Shi, Yingying
    Zhang, Jiehan
    Dianbo Kexue Xuebao/Chinese Journal of Radio Science, 2015, 30 (03): : 530 - 534
  • [27] HEADiv: A High-accuracy Energy-efficient Approximate Divider with Error Compensation
    Wang, Hanghang
    Chen, Ke
    Wu, Bi
    Wang, Chenghua
    Liu, Weiqiang
    Lombardi, Fabrizio
    PROCEEDINGS OF THE 17TH ACM INTERNATIONAL SYMPOSIUM ON NANOSCALE ARCHITECTURES, NANOARCH 2022, 2022,
  • [28] High-Accuracy Estimation of Soft Error Rate using PHYSERD with Circuit Simulation
    Kato, Takashi
    Uemura, Taiki
    Matsuyama, Hideya
    2014 INTERNATIONAL CONFERENCE ON SIMULATION OF SEMICONDUCTOR PROCESSES AND DEVICES (SISPAD), 2014, : 345 - 348
  • [29] Optical System Error Analysis and Calibration Method of High-Accuracy Star Trackers
    Sun, Ting
    Xing, Fei
    You, Zheng
    SENSORS, 2013, 13 (04): : 4598 - 4623
  • [30] High-accuracy aspheric x-ray mirror metrology using Software Configurable Optical Test System/deflectometry
    Huang, Run
    Su, Peng
    Burge, James H.
    Huang, Lei
    Idir, Mourad
    OPTICAL ENGINEERING, 2015, 54 (08)