The detailed structural characterization of N-linked oligosaccharides using a quadrupole ion trap mass spectrometer

被引:0
|
作者
Sheeley, DM
Reinhold, VN
机构
[1] GLAXO WELLCOME INC,DEPT ANALYT CHEM,RES TRIANGLE PK,NC 27709
[2] BOSTON UNIV,SCH MED,DEPT MICROBIOL,BOSTON,MA 02118
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
引用
收藏
页码:38 / 38
页数:1
相关论文
共 50 条
  • [41] Quadrupole Ion Trap Mass Spectrometer for Ice Giant Atmospheres Exploration
    Simcic, J.
    Nikolic, D.
    Belousov, A.
    Atkinson, D.
    Lee, C.
    Madzunkov, S.
    Almodiel, D.
    SPACE SCIENCE REVIEWS, 2021, 217 (01)
  • [42] HIGH-RESOLUTION ON A QUADRUPOLE ION TRAP MASS-SPECTROMETER
    SCHWARTZ, JC
    SYKA, JEP
    JARDINE, I
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (03) : 198 - 204
  • [43] Quadrupole Ion Trap Mass Spectrometer for Ice Giant Atmospheres Exploration
    J. Simcic
    D. Nikolić
    A. Belousov
    D. Atkinson
    C. Lee
    S. Madzunkov
    D. Almodiel
    Space Science Reviews, 2021, 217
  • [44] STRUCTURAL-ANALYSIS OF THE N-LINKED OLIGOSACCHARIDES FROM MURINE GLYCOPHORIN
    ANGEL, AS
    GRONBERG, G
    KROTKIEWSKI, H
    LISOWSKA, E
    NILSSON, B
    ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1991, 291 (01) : 76 - 88
  • [45] COMPARATIVE STRUCTURAL STUDY OF N-LINKED OLIGOSACCHARIDES OF URINARY AND RECOMBINANT ERYTHROPOIETINS
    TSUDA, E
    GOTO, M
    MURAKAMI, A
    AKAI, K
    UEDA, M
    KAWANISHI, G
    TAKAHASHI, N
    SASAKI, R
    CHIBA, H
    ISHIHARA, H
    MORI, M
    TEJIMA, S
    ENDO, S
    ARATA, Y
    BIOCHEMISTRY, 1988, 27 (15) : 5646 - 5654
  • [46] Borinium adduct ion formation with barbiturates in a quadrupole ion-trap mass spectrometer
    Colorado, A
    Brodbelt, J
    JOURNAL OF MASS SPECTROMETRY, 1996, 31 (04): : 403 - 410
  • [47] Ion-molecule reactions of benzoyl ions in a quadrupole ion trap mass spectrometer
    Creaser, CS
    Wiliamson, BL
    JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1996, (03): : 427 - 433
  • [48] EFFECTS OF COLLISIONAL COOLING ON ION DETECTION IN A QUADRUPOLE ION TRAP MASS-SPECTROMETER
    WU, HF
    BRODBELT, JS
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 115 (01): : 67 - 81
  • [49] IMPROVED ACCURACY OF MASS MEASUREMENT WITH A QUADRUPOLE ION-TRAP MASS-SPECTROMETER
    WILLIAMS, JD
    COOKS, RG
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (08) : 524 - 527
  • [50] Ion motion in the rectangular wave quadrupole field and digital operation mode of a quadrupole ion trap mass spectrometer
    Ding, L.
    Kumashiro, S.