Echocardiography for Determining the Optimal Atrioventricular Interval in Patients with Dual Chamber Pacemakers

被引:1
|
作者
Sun, Pin [1 ]
Zhao, Qing [2 ]
Wang, Zhi-Bin [1 ]
Li, Jian-Sheng [1 ]
Wo, Jin-Shan [2 ]
Cai, Shang-Lang [2 ]
机构
[1] Qingdao Univ, Coll Med, Affiliated Hosp, Dept Cardiac Ultrasound, Qingdao 266071, Peoples R China
[2] Qingdao Univ, Coll Med, Affiliated Hosp, Dept Cardiol, Qingdao 266071, Peoples R China
关键词
CARDIAC RESYNCHRONIZATION THERAPY; OPTIMIZATION; DELAY; MANIFESTATIONS; CONDUCTION; BLOCK;
D O I
10.1002/clc.20555
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We investigated the clinical value of Doppler echocardiography for determining the optimal setting of atrioventricular interval in patients with dual chamber pacemakers (DDD). In 38 patients with complete atrioventricular block and DDD pacemakers, the atrioventricular interval was prolonged in a stepwise fashion by 20 ms, from 90 to 250 ms, and cardiac stroke volume and transmitral flow were measured by pulsed Doppler echocardiography. Methods: The optimal atrioventricular interval at which the cardiac stroke volume was maximal was 168.9 +/- 15.6 ms. The atrioventricular interval was 178.4 +/- 23.4 ms when the end of the A wave coincided with complete closure of the mitral valve. Results: There was a significant linear relationship between the optimal atrioventricular interval and the predicted optimal atrioventricular interval (Y = 86.2 +/- 0.5X, r = 0.70, standard error of the estimate [SEE]= 11.5, P < 0.01). Conclusion: The optimal atrioventricular interval setting for DDD pacing can be successfully determined using Doppler echocardiography, which is a noninvasive, repeatable, and simple approach.
引用
收藏
页码:439 / 441
页数:3
相关论文
共 50 条
  • [1] OPTIMAL ATRIOVENTRICULAR INTERVAL IN PATIENTS WITH DUAL CHAMBER PACEMAKERS
    MEHTA, D
    GILMOUR, S
    LAU, CP
    WARD, D
    CAMM, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (02): : 437 - 437
  • [2] NONINVASIVE ASSESSMENT OF OPTIMAL ATRIOVENTRICULAR INTERVAL IN PATIENTS WITH DUAL CHAMBER PACEMAKERS
    MEHTA, D
    GILMOUR, S
    WARD, D
    CAMM, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 715 - 715
  • [3] IS THE OPTIMAL ATRIOVENTRICULAR DELAY THE SAME AT REST AND DURING EXERCISE - AN ASSESSMENT IN PATIENTS WITH DUAL CHAMBER PACEMAKERS
    MEHTA, D
    GILMOUR, S
    LAU, CP
    MEHTA, N
    WARD, DE
    CAMM, AJ
    [J]. BRITISH HEART JOURNAL, 1988, 59 (01): : 93 - 93
  • [4] NONINVASIVE ASSESSMENT OF OPTIMAL ATRIOVENTRICULAR DELAY AT REST AND DURING EXERCISE IN PATIENTS WITH DUAL CHAMBER PACEMAKERS
    MEHTA, D
    GILMOUR, S
    CAMM, AJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (04): : 989 - 989
  • [5] Echocardiographic atrioventricular interval optimization in patients with dual-chamber pacemakers and symptomatic left ventricular systolic dysfunction
    Gilligan, DM
    Sargent, D
    Ponnathpur, V
    Dan, D
    Zakaib, JS
    Ellenbogen, KA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (05): : 629 - 631
  • [6] Automated functional imaging in atrioventricular delay time optimisation in patients with dual chamber pacemakers
    Arik, Osman Ziya
    Kalkan, Gulhan Yuksel
    Sahin, Durmus Yildiray
    Tekin, Kamuran
    Elbasan, Zafer
    Gur, Mustafa
    Kuloglu, Osman
    Gencaslan, Murat
    Turkoglu, Caner
    Ucak, Haci Ali
    Cayli, Murat
    [J]. KARDIOLOGIA POLSKA, 2014, 72 (07) : 640 - 645
  • [7] OPTIMUM AV-INTERVAL IN DUAL CHAMBER PACEMAKERS
    HASKELL, RJ
    FRENCH, WJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (05): : 670 - 675
  • [8] Automated Functional Imaging in Atrioventricular Delay Time Optimization in Patients with Dual Chamber Pacemakers
    Arik, Osman Ziya
    Kalkan, Gulhan Yuksel
    Sahin, Durmus Yildiray
    Elbasan, Zafer
    Gur, Mustafa
    Kuloglu, Osman
    Tekin, Kamuran
    Gencaslan, Murat
    Turkoglu, Caner
    Ucak, Haci Ali
    Cayli, Murat
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : C7 - C7
  • [9] OPTIMAL HEMODYNAMIC PROGRAMMING OF DUAL CHAMBER PACEMAKERS USING 2D-DOPPLER ECHOCARDIOGRAPHY
    WISH, M
    GOTTDIENER, JS
    CUTLER, DJ
    CHAUVIN, L
    FLETCHER, R
    [J]. CLINICAL RESEARCH, 1984, 32 (02): : A218 - A218
  • [10] OPTIMAL LEFT ATRIOVENTRICULAR SEQUENCE IN DUAL CHAMBER PACING - LIMITATIONS OF PROGRAMMED AV INTERVAL
    WISH, M
    FLETCHER, RD
    GOTTDIENER, JS
    COHEN, AI
    CUTLER, DJ
    ROGERS, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (02) : 507 - 507