Response of LaBr3:Ce scintillation detector itself to fast neutrons

被引:1
|
作者
Liu, C. [1 ,2 ]
Ma, H. [1 ,2 ]
Pan, X. [1 ,2 ]
Zeng, Z. [1 ,2 ]
Li, J. [1 ,2 ]
Zhang, H. [1 ,2 ]
机构
[1] Tsinghua Univ, Key Lab Particle & Radiat Imaging, Minist Educ, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Gamma detectors (scintillators; CZT; HPG; HgI etc); Neutron detectors (cold; thermal; fast neutrons); NUCLEAR-DATA SHEETS; SPECTROMETER; EFFICIENCY;
D O I
10.1088/1748-0221/14/06/P06029
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The LaBr3:Ce scintillator had been proved to be not only a promising gamma rays detector, but also a potential neutron detector. This dual response performance provided a possibility for the application of the LaBr3:Ce scintillator in neutron-gamma joint survey. However, the reported application of the detector in neutron detection depended on time-of-flight technique, which limited its application in the actual radiation field. To make the detector be useful for neutron measurement in actual mixed neutron-gamma fields, the responses of the LaBr3:Ce detector itself to fast neutrons were studied. Some specific neutron-induced peaks emitted in the neutron inelastic interaction with the detector were proposed. Based on these peaks, the LaBr3:Ce detector could be directly applied to neutron detection without time-of-flight technology. The response relationship between the counts of these neutron-induced gamma peaks in energy deposition spectrum of the detector and neutron ambient dose equivalent exhibited good linearity. The verification experiments were conducted with a 3 in x 3 in LaBr3:Ce detector in the reference calibration field formed by the Am-241-Be neutron source. In the neutron ambient dose equivalent rates range from 14.6 mu Sv h(-1) to 183.0 mu Sv h(-1), the linear response relationship was proved available. The studied results provided foundation for simultaneous neutron and gamma ambient dose equivalent measurements based on the LaBr3:Ce detector in mix radiation fields.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] The energy response of LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals for GECAM
    Feng, Pei-Yi
    Sun, Xi-Lei
    An, Zheng-Hua
    Deng, Yong
    Wang, Cheng-Er
    Jiang, Huang
    Li, Jun-Jie
    Zhang, Da-Li
    Li, Xin-Qiao
    Xiong, Shao-Lin
    Zheng, Chao
    Gong, Ke
    Yang, Sheng
    Liu, Xiao-Jing
    Gao, Min
    Wen, Xiang-Yang
    Liu, Ya-Qing
    Xu, Yan-Bing
    Zhao, Xiao-Yun
    Liu, Jia-Cong
    Zhang, Fan
    Lu, Hong
    NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (02)
  • [22] LaBr3:Ce crystal:: The latest advance for scintillation cameras
    Pani, R.
    Pellegrini, R.
    Cinti, M. N.
    Bennati, P.
    Betti, M.
    Vittorini, F.
    Mattioli, M.
    Trotta, G.
    Cencelli, V. Orsolini
    Scafe, R.
    Montani, L.
    Navarria, F.
    Bollini, D.
    Baldazzi, G.
    Moschini, G.
    Rossi, P.
    de Notaristefani, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01): : 268 - 269
  • [23] The energy response of LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals for GECAM
    Pei?Yi Feng
    Xi?Lei Sun
    Zheng?Hua An
    Yong Deng
    Cheng?Er Wang
    Huang Jiang
    Jun?Jie Li
    Da?Li Zhang
    Xin?Qiao Li
    Shao?Lin Xiong
    Chao Zheng
    Ke Gong
    Sheng Yang
    Xiao?Jing Liu
    Min Gao
    Xiang?Yang Wen
    Ya?Qing liu
    Yan?Bing Xu
    Xiao?Yun Zhao
    Jia?Cong Liu
    Fan Zhang
    Hong Lu
    Nuclear Science and Techniques, 2024, 35 (02) : 59 - 71
  • [24] The sensitivity of LaBr3:Ce scintillation detectors to low energy neutrons: Measurement and Monte Carlo simulation
    Tain, J. L.
    Agramunt, J.
    Algora, A.
    Aprahamian, A.
    Cano-Ott, D.
    Fraile, L. M.
    Guerrero, C.
    Jordan, M. D.
    Mach, H.
    Martinez, T.
    Mendoza, E.
    Mosconi, M.
    Nolte, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 774 : 17 - 24
  • [25] X-ray and gamma-ray response of a 2" x 2" LaBr3:Ce scintillation detector
    Quarati, F.
    Bos, A. J. J.
    Brandenburg, S.
    Dathy, C.
    Dorenbos, P.
    Kraft, S.
    Ostendorf, R. W.
    Ouspenski, V.
    Owens, Alan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (01): : 115 - 120
  • [26] A phoswich composed of CsI:Na and LaBr3:Ce To improve the low energy response of LaBr3:Ce
    Gao, X.
    He, Y. J.
    Chen, Y. B.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2011, 5 (3-4): : 344 - 347
  • [27] Digital processing of signals from LaBr3:Ce scintillation detectors
    Nakhostin, M.
    Podolyak, Zs
    Regan, P. H.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [28] Measurement of 235U enrichment with a LaBr3 scintillation detector
    Mortreau, P.
    Berndt, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 620 (2-3): : 324 - 331
  • [29] Properties of a very large volume LaBr3:Ce detector
    Giaz, A.
    Pellegri, L.
    Riboldi, S.
    Camera, F.
    Blasi, N.
    Boiano, C.
    Brambilla, S.
    Ceruti, S.
    Crespi, F. C. L.
    Csatlos, M.
    Gulyas, J.
    Krasznahorkay, A.
    Lodetti, S.
    Million, B.
    Stuhl, L.
    Wieland, O.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 331 - 334
  • [30] A gated LaBr3(Ce) detector for border protection applications
    Etile, A.
    Denis-Petit, D.
    Gaudefroy, L.
    Meot, V.
    Roig, O.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 877 : 323 - 327