Efficacy of 3-D reconstructed time of flight MRA follow-up of the embolized cerebral aneurysms

被引:5
|
作者
Saguchi, T [1 ]
Murayama, Y [1 ]
Ishibashi, T [1 ]
Ebara, M [1 ]
Irie, K [1 ]
Takao, H [1 ]
Abe, T [1 ]
机构
[1] Jikei Univ, Sch Med, Dept Neurosurg, Minato Ku, Tokyo, Japan
来源
关键词
3-D TOF MRA; cerebral aneurysm; recanalization;
D O I
10.1177/15910199060120S104
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
A follow-up of the embolized cerebral aneurysm with Guglielmi Detachable Coils (GDC) were performed mainly using craniograms and digital subtraction angiograms (DSA) so far Recently, several authors have reported about efficacy of the time of flight (TOF) magnetic resonance angiogram (MRA) as a follow-tip for the embolized cerebral aneurysms. In our institution, 3-D reconstructed TOF MRAs have been performed as a follow-up of the embolized cerebral aneurysms. We examined efficacy of 3-D reconstructed TOF MRA. 3-D TOF MRA was performed for a follow-up of the embolized cerebral aneurysms at our outpatient clinic in 35 patients. Morphological examination of the 3-D images between 3-D TOF MRA and 3-D DSA was performed. Almost similar images of 3-D MRA were obtained after 3-D reconstruction as compared with those of 3-D DSA. In three cases, recanalization was suspected in the 3-D TOF MRA. And recanalization was confirmed in the 3-D DSA actually. A quality of 3-D TOF MRA for a diagnosis of recanalization was good and practical. However, in two cases, arteries were partially disappeared in the 3-D TOF MRA. These were the artifact due to coil mass and this is a current limitation of 3-D TOF MRA. The images of 3-D TOF MRA that were reconstructed in the 3-D workstation were very similar to those of 3-D DSA. 3-D reconstructed TOF MRA was very useful for a less-invasive diagnosis of a recanalization of the embolized cerebral aneurysms.
引用
收藏
页码:45 / 48
页数:4
相关论文
共 50 条
  • [31] Contrast-Enhanced Time-Resolved MRA for Follow-Up of Intracranial Aneurysms Treated with the Pipeline Embolization Device
    Boddu, S. R.
    Tong, F. C.
    Dehkharghani, S.
    Dion, J. E.
    Saindane, A. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (11) : 2112 - 2118
  • [32] The effectiveness of 3T time-of-flight magnetic resonance angiography for follow-up evaluations after the stent-assisted coil embolization of cerebral aneurysms
    Cho, Won-Sang
    Kim, Sam Soo
    Lee, Seung Jin
    Kim, Sung Hun
    ACTA RADIOLOGICA, 2014, 55 (05) : 604 - 613
  • [33] ANGIOGRAPHIC FOLLOW-UP OF LARGE CEREBRAL AVMS INCOMPLETELY EMBOLIZED WITH ISOBUTYL-2-CYANOACRYLATE
    VINUELA, F
    FOX, AJ
    PELZ, D
    DEBRUN, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1986, 7 (05) : 919 - 925
  • [34] The Goteborg cohort of embolized cerebral arteriovenous malformations: A 6-year follow-up - Comments
    Schramm, J
    Schaller, C
    Rosenwasser, RH
    Forget, TR
    Replogle, RE
    Samson, DS
    Juvela, S
    Hernesniemi, J
    NEUROSURGERY, 2001, 49 (04) : 805 - 806
  • [35] Angiographic follow-up results of GDC-treated cerebral aneurysms
    Hyogo, T
    Kataoka, T
    Hayase, K
    Nakamura, H
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 (06): : 1179 - 1181
  • [37] 3D Geometric Analysis of the Aorta in 3D MRA Follow-Up Pediatric Image Data
    Woerz, Stefan
    Alrajab, Abdulsattar
    Arnold, Raoul
    Eichhorn, Joachim
    von Tengg-Kobligk, Hendrik
    Schenk, Jens-Peter
    Rohr, Karl
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [38] Recanalisation of cerebral artery aneurysms treated endovascularly - a midterm follow-up
    Tomalski, Witold
    Knap, Daniel
    Zak, Amadeusz
    Binek, Lukasz
    Dewerenda-Sikora, Milena
    Krzan, Aleksandra
    Puz, Przemyslaw
    Tomalski, Maciej
    Sieron, Dominik
    Piwowarski, Wojciech
    Kuczmik, Waclaw
    Lasek-Bal, Anetta
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2020, 54 (06) : 524 - 530
  • [39] Usefulness of Noncontrast-Enhanced Silent Magnetic Resonance Angiography (MRA) for Treated Intracranial Aneurysm Follow-up in Comparison with Time-of-Flight MRA
    Ryu, Kyeong Hwa
    Baek, Hye Jin
    Moon, Jin Il
    Choi, Bo Hwa
    Park, Sung Eun
    Ha, Ji Young
    Park, Hyun
    Kim, Seung Soo
    Kim, Jung-Soo
    Cho, Soo Buem
    Carl, Michael
    NEUROSURGERY, 2020, 87 (02) : 220 - 228
  • [40] The sensitivity and specificity of TOF-MRA compared with DSA in the follow-up of treated intracranial aneurysms
    Xiang, Sishi
    Fan, Fu
    Hu, Peng
    Yang, Kun
    Zhai, Xiaodong
    Geng, Jiewen
    Ji, Zhe
    Lu, Jie
    Zhang, Hongqi
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (12) : 1172 - +