Impact of ASHRAE Environmental Classes on Data Centers

被引:0
|
作者
David, Milnes P. [1 ]
Schmidt, Roger R. [1 ]
机构
[1] IBM Corp, STG Adv Thermal Energy Efficiency Lab, Poughkeepsie, NY 12601 USA
关键词
ASHRAE; data centers; energy-efficiency;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Data centers consume a significant amount of energy in the US and worldwide, much of which is consumed by the cooling infrastructure, particularly the chiller plant and computer room air conditioners and air handlers. To enable energy efficient data center designs, ASHRAE added two new IT environmental classes, A3 and A4, with associated allowable inlet air temperatures of 40C and 45C respectively. IT equipment that meet these new allowable environmental envelopes can operate in data centers with minimal refrigeration cooling and instead rely on ambient free cooling. In this paper we investigate the impact of allowing a data center to operate up to the A3 limit of 40C on total data center energy use for 3 different types of servers in a chiller-less data center located in a variety of locations. The study finds that though facility power reduces as the demand for cold air reduces, the increase in IT power consumption, due to fan speed-up, can offset these savings and in some cases result in an overall increase in data center power. Thus the most energy efficient operating point is dependant on the specific energy use profiles of the infrastructure and the IT equipment. The higher allowable temperature can also result in higher failure rates and an increased risk of equipment or service loss due to data center cooling failures. This paper also presents a study on the potential for chiller elimination and chiller use reduction across the US, Europe and in India by operating in the various ASHRAE envelopes. For wet, water side economized data centers, A2 and A3 equipment is sufficient to almost completely remove the need for chillers in many geographic locations.
引用
收藏
页码:1092 / 1099
页数:8
相关论文
共 50 条
  • [31] PRESENTATION - NAMES AND HISTORICAL DATA - ASHRAE PIONEERS
    PAYNE, JJ
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (05): : 58 - 58
  • [32] Updating the ASHRAE Climatic Data for Design and Standards
    Thevenard, Didier
    Gueymard, Christian A.
    [J]. ASHRAE TRANSACTIONS 2010, VOL 116, PT 2, 2010, 116 : 444 - +
  • [33] Data analysis for environmental impact of dredging
    Manap, Norpadzlihatun
    Voulvoulis, Nikolaos
    [J]. JOURNAL OF CLEANER PRODUCTION, 2016, 137 : 394 - 404
  • [34] CENTERS OF SEMIGROUP RINGS AND CONJUGACY CLASSES
    DAUNS, J
    [J]. SEMIGROUP FORUM, 1989, 38 (03) : 355 - 364
  • [35] Energy and environmental assessment of on-site power and cooling for data centers
    Erden, Hamza S.
    Khalifa, H. Ezzat
    [J]. HVAC and R Research, 2012, 18 (1-2): : 51 - 66
  • [36] Research on the Comprehensive Environmental Performance Assessment System for Green Data Centers
    Ji, Yingbo
    Han, Chunlin
    [J]. ICCREM 2015: ENVIRONMENT AND THE SUSTAINABLE BUILDING, 2015, : 292 - 301
  • [37] GreenHop: Open Source Environmental Monitoring for Small and Medium Data Centers
    Camargo, Daniel Scheidemantel
    Miers, Charles Christian
    Koslovski, Guilherme Piegas
    Pillon, Mauricio Aronne
    [J]. PROCEEDINGS OF THE 2016 35TH INTERNATIONAL CONFERENCE OF THE CHILEAN COMPUTER SCIENCE SOCIETY (SCCC), 2016,
  • [38] Internet of Things based Physical and Environmental Monitoring System for Data Centers
    Khan, Wazir Zada
    Aalsalem, M. Y.
    Zangoti, H. M.
    Zahid, M.
    Afzal, M. Khalil
    [J]. 2018 INTERNATIONAL CONFERENCE ON RADAR, ANTENNA, MICROWAVE, ELECTRONICS, AND TELECOMMUNICATIONS (ICRAMET), 2018, : 41 - 44
  • [39] Energy and environmental assessment of on-site power and cooling for data centers
    Erden, Hamza S.
    Khalifa, H. Ezzat
    [J]. HVAC&R RESEARCH, 2012, 18 (1-2): : 51 - 66
  • [40] Characterizing the Impact of the Workload on the Value of Dynamic Resizing in Data Centers
    Wang, Kai
    Lin, Minghong
    Ciucu, Florin
    Wierman, Adam
    Lin, Chuang
    [J]. 2013 PROCEEDINGS IEEE INFOCOM, 2013, : 515 - 519