Impact of ASHRAE Environmental Classes on Data Centers

被引:0
|
作者
David, Milnes P. [1 ]
Schmidt, Roger R. [1 ]
机构
[1] IBM Corp, STG Adv Thermal Energy Efficiency Lab, Poughkeepsie, NY 12601 USA
关键词
ASHRAE; data centers; energy-efficiency;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Data centers consume a significant amount of energy in the US and worldwide, much of which is consumed by the cooling infrastructure, particularly the chiller plant and computer room air conditioners and air handlers. To enable energy efficient data center designs, ASHRAE added two new IT environmental classes, A3 and A4, with associated allowable inlet air temperatures of 40C and 45C respectively. IT equipment that meet these new allowable environmental envelopes can operate in data centers with minimal refrigeration cooling and instead rely on ambient free cooling. In this paper we investigate the impact of allowing a data center to operate up to the A3 limit of 40C on total data center energy use for 3 different types of servers in a chiller-less data center located in a variety of locations. The study finds that though facility power reduces as the demand for cold air reduces, the increase in IT power consumption, due to fan speed-up, can offset these savings and in some cases result in an overall increase in data center power. Thus the most energy efficient operating point is dependant on the specific energy use profiles of the infrastructure and the IT equipment. The higher allowable temperature can also result in higher failure rates and an increased risk of equipment or service loss due to data center cooling failures. This paper also presents a study on the potential for chiller elimination and chiller use reduction across the US, Europe and in India by operating in the various ASHRAE envelopes. For wet, water side economized data centers, A2 and A3 equipment is sufficient to almost completely remove the need for chillers in many geographic locations.
引用
收藏
页码:1092 / 1099
页数:8
相关论文
共 50 条
  • [1] Estimating the environmental impact of Data Centers
    Ferreira, Joao
    Callou, Gustavo
    Josua, Albert
    Maciel, Paulo
    [J]. 2018 IEEE 17TH INTERNATIONAL SYMPOSIUM ON NETWORK COMPUTING AND APPLICATIONS (NCA), 2018,
  • [2] ASHRAE offers guidance on cooling data centers
    不详
    [J]. ASHRAE JOURNAL, 2004, 46 (02) : 9 - 9
  • [3] Evaluating Life-Cycle Environmental Impact of Data Centers
    Shah, Amip
    Bash, Cullen
    Sharma, Ratnesh
    Christian, Tom
    Watson, Brian J.
    Patel, Chandrakant
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2011, 133 (03)
  • [4] An Artificial Neural Network Approach to Forecast the Environmental Impact of Data Centers
    Ferreira, Joao
    Callou, Gustavo
    Josua, Albert
    Tutsch, Dietmar
    Maciel, Paulo
    [J]. INFORMATION, 2019, 10 (03)
  • [5] THE ENVIRONMENTAL FOOTPRINT OF DATA CENTERS
    Shah, Amip
    Bash, Cullen
    Sharma, Ratnesh
    Christian, Tom
    Watson, Brian J.
    Patel, Chandrakant
    [J]. IPACK 2009: PROCEEDINGS OF THE ASME INTERPACK CONFERENCE 2009, VOL 2, 2010, : 653 - 662
  • [6] ASHRAE makes impact
    不详
    [J]. ASHRAE JOURNAL, 2002, 44 (08) : 4 - 4
  • [7] Achieving Energy Efficient Data Centers Using Cooling Path Management Coupled with ASHRAE Standards
    Green, Matthew
    Karajgikar, Saket
    Vozza, Philip
    Gmitter, Nick
    Dyer, Dan
    [J]. 2012 28TH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM (SEMI-THERM), 2012, : 288 - +
  • [8] ASHRAE - IMPACT THROUGH RESEARCH
    BAHNFLET.DR
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1974, 16 (07): : 67 - 67
  • [9] CODE COMPLIANCE IN A RAPIDLY CHANGING INDUSTRY: DATA CENTERS AND THE DEVELOPMENT OF BSR/ASHRAE 90.4P
    Comperchio, Dan
    Behere, Sameer
    [J]. PROCEEDINGS OF THE ASME POWER CONFERENCE, 2016, 2016,
  • [10] The environmental footprint of data centers in the United States
    Siddik, Md Abu Bakar
    Shehabi, Arman
    Marston, Landon
    [J]. ENVIRONMENTAL RESEARCH LETTERS, 2021, 16 (06):