Unstable proximal extraarticular tibia fractures - A biomechanical evaluation of four methods of fixation

被引:61
|
作者
Peindl, RD
Zura, RD
Vincent, A
Coley, ER
Bosse, MJ
Sims, SH
机构
[1] Carolinas Med Ctr, Orthopaed Engn Res, Charlotte, NC 28232 USA
[2] Med Coll Georgia, Augusta, GA 30912 USA
[3] Christchurch Hosp, Christchurch, New Zealand
[4] Miller Orthopaed Clin, Charlotte, NC USA
关键词
proximal tibia; plate fixation; external fixation; periarticular plate; locking plate;
D O I
10.1097/00005131-200409000-00010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To compare the biomechanical stability of extraarticular proximal tibia fractures reconstructed using a double-plate construct, locking plate system, hybrid external fixator, and single lateral periarticular plate, all from the same manufacturer. Design: Standardized proximal fibial fractures (AO classification 41-A3.2 and A3.3) in synthetic tibiae were stabilized using one of the four constructs. Load versus proximal fragment translation and rotation were monitored in each case. Fixation was evaluated for moderately unstable and completely unstable fractures simulated by wedge and gap osteotomies of the proximal femur. Setting: Academic medical center biomechanical engineering laboratory. Main Outcome Measurements: Proximal fragment axial displacement, varus rotation, and posterior rotation versus applied load for each of the constructs. Results: The double-plate construct was significantly stiffer than all other constructs with regard to resistance to axial displacement, varus rotation, and posterior rotation for both types of unstable fractures. With regard to axial stiffness, the double-plate construct was statistically similar to an intact tibia for moderately stable fractures. The locking plate and the external fixator were similar for stabilization of moderately unstable fractures, whereas the locking plate and the periarticular plate were significantly stiffer than the external fixator construct for completely unstable fractures. Conclusion: For axial load applied to a wedge or gap osteotomy of the proximal tibia, the double-plate construct provided significantly more rigidity than the other constructs. The locking plate, periarticular plate, and hybrid external fixator tested provided similar rigidity for the wedge osteotomy, but for the gap osteotomy the external fixator could not support 600N without complete closure of the gap.
引用
收藏
页码:540 / 545
页数:6
相关论文
共 50 条
  • [21] Anatomical and biomechanical evaluation of an intramedullary nail for fractures of proximal humerus fractures based on tuberosity fixation
    Clavert, Ph.
    Hatzidalds, A.
    Boileau, P.
    CLINICAL BIOMECHANICS, 2016, 32 : 108 - 112
  • [22] Biomechanical evaluation of a new gliding screw concept for the fixation of proximal humeral fractures
    Acklin, Y. P.
    Zderic, I
    Inzana, J. A.
    Grechenig, S.
    Schwyn, R.
    Richards, R. G.
    Gueorguiev, B.
    BONE & JOINT RESEARCH, 2018, 7 (06): : 422 - 429
  • [23] Locked plate fixation and intramedullary nailing for proximal humerus fractures: A biomechanical evaluation
    Hessmann, MH
    Hansen, WSM
    Krummenauer, F
    Pol, TF
    Rommens, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 58 (06): : 1194 - 1201
  • [24] Biomechanical Comparison of Four Methods of Fixation of a Polymeric Cranial Cruciate Ligament in the Canine Femur and Tibia
    Bamhart, Matthew D.
    Bufkin, Brian W.
    Litsky, Alan S.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2019, 32 (02) : 112 - 116
  • [25] Fixation of rotationally unstable extracapsular proximal femoral fractures
    Massoud, Elsayed Ibraheem Elsayed
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2018, 24 (02): : 168 - 174
  • [26] Plate fixation of extraarticular fractures of the proximal phalanx - are problems solved with new implants?
    Brei, P.
    Voegelin, E.
    Franz, T.
    BRITISH JOURNAL OF SURGERY, 2014, 101 : 12 - 12
  • [27] Biomechanical evaluation of calcium phosphate cement-augmented fixation of unstable intertrochanteric fractures
    Elder, S
    Frankenburg, E
    Goulet, J
    Yetkinler, D
    Poser, R
    Goldstein, S
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (06) : 386 - 393
  • [28] Biomechanical evaluation of a new technique for external fixation of unstable supracondylar humerus fractures in children
    Hohloch, Lisa
    Konstantinidis, Lukas
    Wagner, Ferdinand C.
    Strohm, Peter C.
    Suedkamp, Norbert P.
    Reising, Kilian
    TECHNOLOGY AND HEALTH CARE, 2015, 23 (04) : 453 - 461
  • [29] COMMINUTED FRACTURES OF THE POSTERIOR WALL OF THE ACETABULUM - A BIOMECHANICAL EVALUATION OF FIXATION METHODS
    GOULET, JA
    ROULEAU, JP
    MASON, DJ
    GOLDSTEIN, SA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (10): : 1457 - 1463
  • [30] Compartment pressures after submuscular fixation of proximal tibia fractures
    Cole, PA
    Zlowodzki, M
    Kregor, PJ
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 : S43 - S46