Unstable proximal extraarticular tibia fractures - A biomechanical evaluation of four methods of fixation

被引:61
|
作者
Peindl, RD
Zura, RD
Vincent, A
Coley, ER
Bosse, MJ
Sims, SH
机构
[1] Carolinas Med Ctr, Orthopaed Engn Res, Charlotte, NC 28232 USA
[2] Med Coll Georgia, Augusta, GA 30912 USA
[3] Christchurch Hosp, Christchurch, New Zealand
[4] Miller Orthopaed Clin, Charlotte, NC USA
关键词
proximal tibia; plate fixation; external fixation; periarticular plate; locking plate;
D O I
10.1097/00005131-200409000-00010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To compare the biomechanical stability of extraarticular proximal tibia fractures reconstructed using a double-plate construct, locking plate system, hybrid external fixator, and single lateral periarticular plate, all from the same manufacturer. Design: Standardized proximal fibial fractures (AO classification 41-A3.2 and A3.3) in synthetic tibiae were stabilized using one of the four constructs. Load versus proximal fragment translation and rotation were monitored in each case. Fixation was evaluated for moderately unstable and completely unstable fractures simulated by wedge and gap osteotomies of the proximal femur. Setting: Academic medical center biomechanical engineering laboratory. Main Outcome Measurements: Proximal fragment axial displacement, varus rotation, and posterior rotation versus applied load for each of the constructs. Results: The double-plate construct was significantly stiffer than all other constructs with regard to resistance to axial displacement, varus rotation, and posterior rotation for both types of unstable fractures. With regard to axial stiffness, the double-plate construct was statistically similar to an intact tibia for moderately stable fractures. The locking plate and the external fixator were similar for stabilization of moderately unstable fractures, whereas the locking plate and the periarticular plate were significantly stiffer than the external fixator construct for completely unstable fractures. Conclusion: For axial load applied to a wedge or gap osteotomy of the proximal tibia, the double-plate construct provided significantly more rigidity than the other constructs. The locking plate, periarticular plate, and hybrid external fixator tested provided similar rigidity for the wedge osteotomy, but for the gap osteotomy the external fixator could not support 600N without complete closure of the gap.
引用
收藏
页码:540 / 545
页数:6
相关论文
共 50 条
  • [1] Hybrid external fixation of proximal tibia fractures: Biomechanical analysis of four commercial systems
    Voor, Michael
    Antoci, Valentin
    Kam, Boon
    Roberts, Craig
    ORTHOPEDICS, 2007, 30 (12) : 1033 - 1038
  • [2] Fixation of proximal tibia fractures by a retrograde nail: a biomechanical investigation
    A. Pommer
    A. Wieser
    M. P. Hahn
    A. Dávid
    G. Muhr
    Archives of Orthopaedic and Trauma Surgery, 2000, 120 : 212 - 214
  • [3] Fixation of proximal tibia fractures by a retrograde nail:: a biomechanical investigation
    Pommer, A
    Wieser, A
    Hahn, MP
    Dávid, A
    Muhr, G
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2000, 120 (3-4) : 212 - 214
  • [4] Biomechanical evaluation of different fixation methods for fracture dislocation involving the proximal tibia
    Jiang, Rui
    Luo, Cong-Feng
    Zeng, Bing-Fang
    CLINICAL BIOMECHANICS, 2008, 23 (08) : 1059 - 1064
  • [5] BIOMECHANICAL SUBSTANTIATION OF THE CHOICE OF THE METHOD FOR FIXING UNSTABLE FRACTURES OF THE PROXIMAL TIBIA
    Chip, Yevhen
    Kalashnikov, Andryi
    Protsenko, Volodymyr
    Kalashnikov, Oleksii
    Stavinsky, Yurii
    Pelypenko, Oleksandr
    ARCHIV EUROMEDICA, 2023, 13 (01):
  • [6] Percutaneous Fixation of Unstable Proximal Phalanx Fractures: A Biomechanical Study
    Nikci, Valdet
    Effiong, Linda
    Freibott, Christina E.
    Gardner, Thomas R.
    Strauch, Robert J.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2023, 18 (02): : 282 - 287
  • [7] Biomechanical Evaluation of Four Methods for Internal Fixation of Comminuted Subtrochanteric Fractures
    Wang, Jie
    Ma, Jian-xiong
    Jia, Hao-bo
    Chen, Yang
    Yang, Yang
    Ma, Xin-long
    MEDICINE, 2016, 95 (19)
  • [8] Biomechanical evaluation of various fixation methods for proximal extra-articular tibial fractures
    Feng, Wei
    Fu, Li
    Liu, Jianguo
    Qi, Xin
    Li, Dongsong
    Yang, Chen
    JOURNAL OF SURGICAL RESEARCH, 2012, 178 (02) : 722 - 727
  • [9] Intramedullary stabilization of extraarticular proximal tibial fractures: A biomechanical comparison of intramedullary and extramedullary implants including a new Proximal Tibia Nail (PTN)
    Hansen, Matthias
    Mehler, Dorothea
    Hessmann, Martin Henri
    Blum, Jochen
    Rommens, Pol Maria
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (10) : 701 - 709
  • [10] INDIRECT REDUCTION AND COMPOSITE FIXATION OF EXTRAARTICULAR PROXIMAL TIBIAL FRACTURES