Contrast medium Pd/Pa ratio in comparison to fractional flow reserve, quantitative flow ratio and instantaneous wave-free ratio for evaluation of intermediate coronary lesions

被引:7
|
作者
Kleczynski, Pawel [1 ]
Dziewierz, Artur [2 ]
Rzeszutko, Lukasz [2 ]
Dudek, Dariusz [2 ]
Legutko, Jacek [1 ]
机构
[1] Jagiellonian Univ, John Paul II Hosp, Inst Cardiol, Dept Intervent Cardiol,Med Coll, Krakow, Poland
[2] Jagiellonian Univ, Univ Hosp, Inst Cardiol, Dept Cardiol 2,Med Coll, Krakow, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2020年 / 16卷 / 04期
关键词
coronary artery disease; fractional flow reserve; quantitative flow ratio; instantaneous wave free ratio; Pd/Pa; STENOSIS; ANGIOGRAPHY; HYPEREMIA; EFFICACY; ACCURACY; INFUSION;
D O I
10.5114/aic.2020.101762
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Contrast medium Pd/Pa ratio (cFFR) was introduced as an alternative to fractional flow reserve (FFR). Aim: To assess the accuracy of cFFR in predicting of FFR, quantitative flow ratio (QFR) and instantaneous wave-free ratio (iFR). Material and methods: Resting Pd/Pa, cFFR, FFR, QFR, and iFR were measured in 110 intermediate coronary lesions. cFFR was obtained after intracoronary injection of contrast medium. FFR was measured after the intravenous administration of adenosine. QFR was derived from fixed empiric hyperemic flow velocity based on coronary angiography. iFR was calculated by measuring the resting pressure gradient across a coronary lesion during diastole. Results: Forty-four patients with 110 intermediate coronary lesions were enrolled. Mean baseline Pd/Pa was 0.93 +/- 0.05. Mean cFFR value was similar to FFR value (0.83 +/- 0.09 vs. 0.81 +/- 0.09; p = 0.13) and QFR (0.81 +/- 0.1; p = 0.69) and iFR (0.90 +/- 0.07; p = 0.1). A total of 46 vessels (41.8%) had FFR <= 0.80, 50 (45.5%) vessels had cFFR <= 0.83, 44 (40.0%) vessels had QFR <= 0.80, and 38 (34.5%) vessels had iFR <= 0.89. An excellent agreement between cFFR and resting Pd/Pa, FFR, QFR, and iFR was confirmed (intraclass correlation coefficients of 0.83, 0.99, 0.98, and 0.88, respectively). The optimal cutoff value of cFFR was 0.83 for prediction of FFR <= 0.80 with sensitivity, specificity, and accuracy of 96.9%, 97.8%, and 97.3%, respectively. 100% sensitivity was observed for a cutoff value of 0.82 and 100% specificity for a cutoff value of 0.84; AUC = 0.998 (0.995-1.00); p < 0.001. Conclusions: Contrast medium Pd/Pa ratio seems to be accurate in predicting the functional significance of borderline coronary lesions assessed with FFR, iFR, and QFR.
引用
收藏
页码:384 / 390
页数:7
相关论文
共 50 条
  • [41] Instantaneous Wave-Free Ratio and Resting Pd/Pa in Tandem Lesions
    Huang, Xiangke
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (18) : 1902 - 1902
  • [42] Evaluation of Instantaneous Wave-Free Ratio and Fractional Flow Reserve in Severe Aortic Valve Stenosis
    Jo, Ha Hye
    Choi, Yeonwoo
    Kim, Hoyun
    Lee, Jinho
    Kang, Do-Yoon
    Ahn, Jung-Min
    Park, Duk-Woo
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (16) : S45 - S45
  • [43] Evaluation of Instantaneous Wave-Free Ratio and Fractional Flow Reserve in Severe Aortic Valve Stenosis
    Jo, Ha Hye
    Kang, Do-Yoon
    Lee, Joong Min
    Lim, So-Min
    Park, Young-Sun
    Choi, Yeonwoo
    Kim, Hoyun
    Lee, Jinho
    Ahn, Jung-Min
    Park, Duk-Woo
    Park, Seung-Jung
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (05) : E013237
  • [44] Reliability of Fractional Flow Reserve and Instantaneous Wave-Free Ratio in Assessing Intermediate Coronary Stenosis in Patients With Atrial Fibrillation
    Bentea, Georgiana Pintea
    Berdaoui, Brahim
    Samyn, Sophie
    Morissens, Marielle
    Rodriguez, Jose Castro
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 162 : 105 - 110
  • [45] Determinants and prognostic implications of instantaneous wave-free ratio in patients with mild to intermediate coronary stenosis: Comparison with those of fractional flow reserve
    Onishi, Kyohei
    Watanabe, Heitaro
    Kakehi, Kazuyoshi
    Ikeda, Tomoyuki
    Takase, Toru
    Yamaji, Kenji
    Ueno, Masafumi
    Kobuke, Kazuhiro
    Nakazawa, Gaku
    Miyazaki, Shunichi
    Iwanaga, Yoshitaka
    PLOS ONE, 2020, 15 (08):
  • [46] COMPARISON OF ADENOSINE FRACTIONAL FLOW RESERVE AND POST-CONTRAST INSTANTANEOUS WAVE-FREE RATIO FOR HEMODYNAMIC ASSESSMENT OF MODERATE CORONARY STENOSES
    Pancholy, Samir B.
    Nanavaty, Sukrut
    Pancholy, Neha
    Pancholy, Maitri
    Pandya, Kavit
    Coppola, John
    Kwan, Tak
    Patel, Tejas
    Patel, Aman
    Tiwari, Hemant
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1058 - 1058
  • [47] Understanding Fractional Flow Reserve/Instantaneous Wave-Free Ratio Discordance Can Provide Coronary Clarity
    Tehrani, David M.
    Seto, Arnold H.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2022, 11 (09):
  • [48] The Role of Fractional Flow Reserve and Instantaneous Wave-Free Ratio Measurements in Patients with Acute Coronary Syndrome
    Ihdayhid, Abdul Rahman
    Koh, Jin-Sin
    Ramzy, John
    Kumar, Arnav
    Michail, Michael
    Brown, Adam
    Samady, Habib
    CURRENT CARDIOLOGY REPORTS, 2019, 21 (12)
  • [49] Hybrid Instantaneous Wave-Free Ratio-Fractional Flow Reserve versus Fractional Flow Reserve in the Real World
    Shuttleworth, Kara
    Smith, Kristina
    Watt, Jonathan
    Smith, Jamie A. L.
    Leslie, Stephen J.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2017, 4
  • [50] The Role of Fractional Flow Reserve and Instantaneous Wave-Free Ratio Measurements in Patients with Acute Coronary Syndrome
    Abdul Rahman Ihdayhid
    Jin-Sin Koh
    John Ramzy
    Arnav Kumar
    Michael Michail
    Adam Brown
    Habib Samady
    Current Cardiology Reports, 2019, 21