Modelling and sizing of a 12 V DC photovoltaic refrigerator

被引:3
|
作者
Daffallah, K. O. [1 ,2 ]
机构
[1] Taibah Univ, Fac Sci, Phys Dept, Madinah, Saudi Arabia
[2] Univ Gezira, Fac Engn & Technol, Elect Dept, Wadmedani, Sudan
关键词
Photovoltaic DC refrigerator; energy consumption; compressor run time; peak sun shine hour (PSH); SOLAR-ENERGY; FUTURE; MANAGEMENT; BATTERY;
D O I
10.1080/01430750.2019.1672580
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Photovoltaic technology has a great opportunity in Kingdom of Saudi Arabia (KSA) due to it is high intensity of solar radiation. In this study sizing of different components of photovoltaic dc refrigerator is carried out at different locations in KSA. Different equations were used in sizing the peak wattage of the solar panel, battery size and the ampere value of the solar charge controller. A photovoltaic refrigerator is installed at Madinah site in KSA, various measurements were done for this refrigerator including the compressor run time, power and energy consumption of the refrigerator. Error between the calculated and measured value is carried out at different operating conditions. The minimum and maximum error of the daily energy consumption of the refrigerator was found to be 0.6% and 2.4% respectively, while the minimum and maximum error of the daily battery ampere-hour consumption was found to be 1.0% and 2.79% respectively.
引用
收藏
页码:749 / 753
页数:5
相关论文
共 50 条
  • [31] On the modelling of linear-assisted DC-DC voltage regulators for photovoltaic solar energy systems
    Martinez-Garcia, Herminio
    Garcia-Vilchez, Encarna
    INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY SYSTEMS AND ENVIRONMENTAL ENGINEERING (ASEE17), 2017, 22
  • [32] Research on 12V DC/DC converter for pure electric vehicles
    Li, Si
    Wang, Yan
    Yin, Tianming
    INTERNATIONAL CONFERENCE MACHINERY, ELECTRONICS AND CONTROL SIMULATION, 2014, 614 : 254 - 260
  • [33] Influence of The Temporal Resolution of The Water Consumption Profile on Photovoltaic Water Pumping Systems Modelling and Sizing
    Meunier, Simon
    Queval, Loic
    Darga, Arouna
    Dessante, Philippe
    Marchand, Claude
    Heinrich, Matthias
    Cherni, Judith
    Vido, Lionel
    Multon, Bernard
    2018 7TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2018, : 494 - 499
  • [34] A GaN and Si Hybrid Solution for 48V-12V Automotive DC-DC Application
    Kou, Lei
    Lu, Juncheng
    2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, : 2858 - 2864
  • [35] THERMAL SIMULATION OF 12V/48V DC-DC CONVERTER WITH LIQUID COOLING
    Duta, Alexandru
    Lelea, Dorin
    INGINERIA AUTOMOBILULUI, 2023, (69): : 21 - 24
  • [36] A new approach to obtain I-V and P-V curves of photovoltaic modules by using DC-DC converters
    Enrique, JM
    Durán, E
    Sidrach-De-Cardona, M
    Andújar, JM
    Bohórquez, MA
    Carretero, J
    CONFERENCE RECORD OF THE THIRTY-FIRST IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE - 2005, 2005, : 1769 - 1772
  • [37] Move to 12V bus eliminates need for isolated dc/dc converters
    Modi, HR
    EDN, 2005, 50 (22) : 83 - 84
  • [38] DC-Bus Voltage Range Extension in 1500 V Photovoltaic Inverters
    Serban, Emanuel
    Ordonez, Martin
    Pondiche, Cosmin
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2015, 3 (04) : 901 - 917
  • [39] An improved algorithm for photovoltaic system sizing
    Nikhil, P. G.
    Subhakar, D.
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 1134 - 1142
  • [40] 400 V to 12 V Step-down DC-DC Power Converter Based on the Differential Concept
    Dal Pont, Neilor Colombo
    Andrade, Jessika Melo
    Dall'Asta, Matheus Schramm
    Lazzarin, Telles Brunelli
    Lehman, Brad
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 1269 - 1274