An algorithm to auto-match the fiducial markers for CT Image-Guided Surgical Navigation System

被引:0
|
作者
Liang Rui [1 ]
Zhang Jianxun [1 ]
Feng Changli [1 ]
Dai Yu [1 ]
Zhao Roger [2 ]
机构
[1] Nankai Univ, Inst Robot & Automat Informat Syst, Tianjin 300071, Peoples R China
[2] Acton Med Device CorpOf Guangzhou, Guangzhou 510110, Guangdong, Peoples R China
关键词
Auto-match Algorithm; Fiducial Markers; Correlation Coefficient; REGISTRATION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The performance of matching the fiducial markers plays an important role in the accuracy of the CT Image-Guided Surgical Navigation System (IGNS). This paper proposed a new algorithm for finding markers in CT image automatically and realizing the one-to-one correspondence between the fiducial markers of CT Image space in IGNS and the sensors of Cartesian space in magnetic field. Firstly, the CT images are segmented by the 3D region growing method. Secondly, upon criteria which is using the length and volumn of the sensors, several suspicious connected components are identified as the possible markers. After the identification, the 3D center of the suspicious connected components are computed. In the end, the one-to-one correspondence is made by calculating the correlation coefficients between the coordinates of suspicious connected components in image space and that of the sensors in magnetic field. The algorithm was applied to both the adaptability and the precision experiments on two models. The result shows that even the precise parameters of the markers are not known, most of them can still be found quickly. And the errors reach the sub-voxel precision. The algorithm is stable, self-adaptive and easy to use.
引用
下载
收藏
页码:4854 / 4859
页数:6
相关论文
共 50 条
  • [21] OPTIMAL FIDUCIAL CONFIGURATION IN IMAGE-GUIDED NEUROSURGERY USING A GENETIC ALGORITHM
    Gastaldi, Laura
    Battezzato, Alessandro
    Bernucci, Claudio
    Mannino, Marco
    Pastorelli, Stefano
    PROCEEDINGS OF THE ASME 10TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS, 2010, VOL 1, 2010, : 767 - 774
  • [22] Face Registration and Surgical Instrument Tracking for Image-guided Surgical Navigation
    Zhang, Yan
    Shen, Xukun
    Hu, Yong
    2016 INTERNATIONAL CONFERENCE ON VIRTUAL REALITY AND VISUALIZATION (ICVRV 2016), 2016, : 65 - 71
  • [23] MRI visibility of gold fiducial markers for image-guided radiotherapy of rectal cancer
    van den Ende, Roy P. J.
    Rigter, Lisanne S.
    Kerkhof, Ellen M.
    van Meerten, Els L. van Persijn
    Rijkmans, Eva C.
    Lambregts, Doenja M. J.
    van Triest, Baukelien
    van Leerdam, Monique E.
    Staring, Marius
    Marijnen, Corrie A. M.
    van der Heide, Uulke A.
    RADIOTHERAPY AND ONCOLOGY, 2019, 132 : 93 - 99
  • [24] Fiducial markers implantation for prostate image-guided radiotherapy: a report on the transperineal approach
    Luigi De Cicco
    Stefano Bracelli
    La radiologia medica, 2019, 124 : 132 - 135
  • [25] Fiducial markers implantation for prostate image-guided radiotherapy: a report on the transperineal approach
    De Cicco, Luigi
    Bracelli, Stefano
    RADIOLOGIA MEDICA, 2019, 124 (02): : 132 - 135
  • [26] Intraprostatic calcifications as natural fiducial markers in image-guided radiotherapy for prostate cancer
    Sbai, A.
    Thariat, J.
    Tachfouti, N.
    Pan, Q.
    Lagrange, J. -L.
    CANCER RADIOTHERAPIE, 2014, 18 (08): : 740 - 744
  • [27] Medical Navigation Based on Coloured Markers for Image-guided Surgery
    Elsamnah, Fahed
    Sediono, Wahju
    MEDICAL AND REHABILITATION ROBOTICS AND INSTRUMENTATION (MRRI2013), 2014, 42 : 138 - 144
  • [28] Automatic localization of the center of fiducial markers in 3D CT/MRI images for image-guided neurosurgery
    Wang, Manning
    Song, Zhijian
    PATTERN RECOGNITION LETTERS, 2009, 30 (04) : 414 - 420
  • [29] Can an ultrasound replace fiducial markers for prostate image-guided radiation therapy?
    Johnston, H.
    Hilts, M.
    Beckham, W.
    Berthelet, E.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S26 - S26
  • [30] MRI visibility of gold fiducial markers for image-guided radiotherapy for rectal cancer
    Van den Ende, R. P. J.
    Rigter, L. S.
    Kerkhof, E. M.
    van Meerten, E. L. Van Persijn
    Rijkmans, E. C.
    Lambregts, D. M. J.
    Van Triest, B.
    Van Leerdam, M. E.
    Staring, M.
    Marijnen, C. A. M.
    Van der Heide, U. A.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1163 - S1164