Comparative studies on radioluminescent and thermoluminescent spectra of LiF:Mg,Cu,P and LiF:Mg,Cu,Si

被引:6
|
作者
Tang, K. [1 ,2 ]
Fan, H. [2 ]
Cui, H. [2 ]
Zhu, H. [2 ]
Liu, Z. [2 ]
机构
[1] State Key Lab NBC Protect Civilian, POB 1044,Ext 201, Beijing 102205, Peoples R China
[2] Solid Dosimetr Detector & Method Lab, POB 1044,Ext 204, Beijing 102205, Peoples R China
关键词
GLOW CURVE STRUCTURE; EMISSION-SPECTRA; LIF-MG; CU; NA; SI PHOSPHOR; SINTERING TEMPERATURES; DOPANTS CONCENTRATIONS; THERMAL-STABILITY; DEPENDENCE; TL; COPPER; DOSIMETER;
D O I
10.1093/rpd/ncv377
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The influence of various annealing treatments on radioluminescent (RL) and thermoluminescent (TL) spectra of LiF:Mg,Cu,Si and LiF:Mg,Cu,P was investigated. The TL and RL emission bands for LiF:Mg,Cu,P are not the same; however, the emission band peaking at similar to 383 nm is predominant in the TL and RL emission for LiF:Mg,Cu,Si. With the increase in annealing temperatures in the range of 240-300A degrees C, for LiF:Mg,Cu,P, the intensity of TL decreases much more rapidly than that of RL. For LiF:Mg,Cu,Si, the area ratios of the two bands of RL and TL remain constant within experimental errors. It suggests that there is a significant decrease in the concentration of recombination centres in LiF:Mg,Cu,P after the annealing, in addition to the decrease in trapping centres, the recombination centres for main TL emission and RL emission in LiF:Mg,Cu,Si are the same, and the recombination centres for TL emission and RL emission in LiF:Mg,Cu,P are not the same. P is a more effective dopant than Si.
引用
收藏
页码:459 / 464
页数:6
相关论文
共 50 条
  • [21] Low temperature studies in LiF:Mg,Cu,P
    Mathur, VK
    Bandyopadhyay, PK
    Barkyoumb, JH
    Cai, GG
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 103 - 106
  • [22] Low temperature studies in LiF:Mg,Cu,P
    Mathur, VK
    Bandyopadhyay, PK
    Barkyoumb, JH
    Cai, GG
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 103 - 106
  • [23] Lithium fluoride:: From LiF:Mg,Ti to LiF:Mg,Cu,P
    Bilski, P
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 199 - 206
  • [24] Lithium fluoride:: From LiF:Mg,Ti to LiF:Mg,Cu,P
    Bilski, P
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 199 - 206
  • [25] The low energy X-ray response of the LiF:Mg:Cu:P thermoluminescent dosemeter:: a comparison with LiF:Mg:Ti
    Edwards, CR
    Mountford, PJ
    Green, S
    Palethorpe, JE
    Moloney, AJ
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (930): : 543 - 547
  • [26] A HIGH-SENSITIVITY LIF-MG,CU,P THERMOLUMINESCENT DOSIMETER
    KOLOTILIN, VV
    HOKHREKOV, VI
    TARASOVA, LM
    ZAKHRIAPIN, SB
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (01): : 169 - 171
  • [27] A comparative study on the thermal stability of LiF:Mg,Ti and LiF:Mg,Cu,P detectors for environmental monitoring
    Alves, JG
    Muñiz, JL
    Ros, JMG
    Delgado, A
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 253 - 257
  • [28] The light sensitivity of thermoluminescent materials:: LiF:Mg,Cu,P, LiF:Mg,Ti and Al2O3:C
    Duggan, L
    Budzanowski, M
    Przegietka, K
    Reitsema, N
    Wong, J
    Kron, T
    RADIATION MEASUREMENTS, 2000, 32 (04) : 335 - 342
  • [29] LiF:Mg,Cu和LiF:Mg,Cu,P低温热释光性质研究
    高慧
    科技信息, 2008, (19) : 525 - 525
  • [30] Thermoluminescence of nanocrystalline LiF:Mg, Cu, P
    Salah, Numan
    Sahare, P. D.
    Rupasov, A. A.
    JOURNAL OF LUMINESCENCE, 2007, 124 (02) : 357 - 364