Comparison of histological findings and the results of energy-dispersive X-ray spectrometry analysis in experimental electrical injury

被引:2
|
作者
Tanaka, Naoko [1 ]
Takakura, Ayaka [1 ]
Miyatake, Nobuyuki [2 ]
Jamal, Mostofa [1 ]
Ito, Asuka [1 ]
Kumihashi, Mitsuru [1 ]
Tsutsui, Kunihiko [3 ]
Ameno, Kiyoshi [1 ]
Kinoshita, Hiroshi [1 ]
机构
[1] Kagawa Univ, Fac Med, Dept Forens Med, 1750-1 Miki, Takamatsu, Kagawa 7610793, Japan
[2] Kagawa Univ, Fac Med, Dept Hyg, Takamatsu, Kagawa, Japan
[3] Kagawa Univ, Fac Med, Sch Nursing, Hlth Sci, Takamatsu, Kagawa, Japan
基金
日本学术振兴会;
关键词
Electrical injury; Current marks; Energy-dispersive X-ray spectrometry (EDX); Metallization;
D O I
10.1016/j.legalmed.2017.12.005
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The findings of histological examination and the results of energy-dispersive X-ray spectrometry (EDX) analysis were compared to identify skin metallization in experimental electrical injury. Rats were divided into three experimental groups (n = 5, each group): control, current exposure for five seconds, and current exposure for ten seconds. A relatively high peak of copper, which was used as an electrical conductor, was detected in formalin-fixed skin samples of the two current exposure groups by EDX. There was a significant increase of the specific Xray intensity in the two current exposure groups compared to the control group. On histological examination, epidermal nuclear elongation was observed in all samples of the two current exposure groups. However, deposition of metal was observed in two samples of each current exposure group. Metallization is an important finding for the diagnosis of electrocution. The present results suggest that EDX analysis is useful for the proof of metallization in electrocution, even where it is not identified on morphological examination.
引用
收藏
页码:20 / 23
页数:4
相关论文
共 50 条
  • [41] OPTIMUM RESOLUTION IN X-RAY ENERGY-DISPERSIVE DIFFRACTOMETRY
    BURAS, B
    NIIMURA, N
    OLSEN, JS
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1978, 11 (APR) : 137 - 140
  • [42] Application of x-ray optics to energy-dispersive spectroscopy
    McCarthy, JJ
    McMillan, DJ
    MICROSCOPY AND MICROANALYSIS, 1998, 4 (06) : 632 - 639
  • [43] Synchrotron energy-dispersive X-ray diffraction tomography
    Hall, C
    Barnes, P
    Cockcroft, JK
    Colston, SL
    Hausermann, D
    Jacques, SDM
    Jupe, AC
    Kunz, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 140 (1-2): : 253 - 257
  • [44] Analysis of a series of Japanese medieval coins via energy-dispersive x-ray fluorescence spectrometry.
    McGrath, E
    Ray, C
    Gaines, T
    Benvenuto, M
    Buffin, B
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U359 - U359
  • [45] Optimization of the identification of chemical compounds by energy-dispersive x-ray fluorescence spectrometry and subsequent multivariate analysis
    Kessler, T
    Hoffmann, P
    Greve, T
    Ortner, HM
    X-RAY SPECTROMETRY, 2002, 31 (05) : 383 - 390
  • [46] Measuring performance of energy-dispersive X-ray systems
    Statham, PJ
    MICROSCOPY AND MICROANALYSIS, 1998, 4 (06) : 605 - 615
  • [47] Characterization of gem stones (rubies and sapphires) by energy-dispersive x-ray fluorescence spectrometry
    Joseph, D
    Lal, M
    Shinde, PS
    Padalia, BD
    X-RAY SPECTROMETRY, 2000, 29 (02) : 147 - 150
  • [48] AUTOMATIC QUALITATIVE IDENTIFICATION OF UNEXPECTED ELEMENTS IN QUANTITATIVE ENERGY-DISPERSIVE X-RAY SPECTROMETRY
    LEYDEN, DE
    BODNAR, WB
    LEMONS, W
    X-RAY SPECTROMETRY, 1981, 10 (01) : 46 - 47
  • [49] DETECTION OF MONOLAYER QUANTITIES OF OXYGEN ON SILICON USING ENERGY-DISPERSIVE X-RAY SPECTROMETRY
    MUSKET, RG
    STRAUSSER, YE
    APPLIED PHYSICS LETTERS, 1980, 37 (05) : 478 - 480
  • [50] Gauge of an energy-dispersive X-ray fluorescence analyzer
    Bukin, KV
    Nakhabtsev, VS
    Romanova, NE
    Kirillov, VN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1998, 41 (03) : 393 - 397