Influence of an electret on the sensitivity of CR-39 nuclear track detector in diffusion chamber

被引:2
|
作者
Nikezic, D. [1 ]
Krstic, D. [1 ]
机构
[1] Univ Kragujevac, Fac Sci, Kragujevac, Serbia
关键词
Diffusion chamber; nuclear track detector; electret; sensitivity; RADON; RN-222;
D O I
10.1007/s12648-009-0039-6
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Cylindrical diffusion chamber for radon measurement equipped with nuclear track detector(CR-39) and electret is considered in this work. Electret is electrostatic analogous of permanent magnet which preserves constant and strong electric field for long time period. Electrets were used to attract radon progeny formed in a cup where CR-39 was placed for radon measurements. In this way the sensitivity of detector could be increased by bringing progeny just in front of detector in more convenient measuring geometry. Influence of distance between electret and detector on sensitivity of such equipment has been investigated theoretically. Different geometrical setups of detector and electret were tested in order to optimize this kind of device. Some results are presented in this report.
引用
收藏
页码:851 / 855
页数:5
相关论文
共 50 条
  • [41] Measurement of alpha particle range in CR-39 detector using nuclear track profiles
    EL-Araby, Entesar H.
    Shabaan, Doaa H.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (01) : 139 - 144
  • [42] THE LOW VELOCITY RESPONSE OF THE SOLID-STATE NUCLEAR TRACK DETECTOR CR-39
    SNOWDENIFFT, DP
    PRICE, PB
    PHYSICS LETTERS B, 1992, 288 (3-4) : 250 - 253
  • [43] Energy calibration of a CR-39 nuclear-track detector irradiated by charged particles
    Zhang, Yue
    Wang, Hong-Wei
    Ma, Yu-Gang
    Liu, Long-Xiang
    Cao, Xi-Guang
    Fan, Gong-Tao
    Zhang, Guo-Qiang
    Fang, De-Qing
    NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (06)
  • [44] Utilizing plasma interaction as a novel etching technique for CR-39 nuclear track detector
    Abdulkader Makki Dahham
    Nada Farhan Kadhim
    Raghad S. Mohammed
    The European Physical Journal Plus, 140 (4)
  • [45] Single-ion detection using nuclear track detector CR-39 plastic
    Hara, K
    Koh, M
    Matsukawa, T
    Tanii, T
    Ohdomari, I
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (12): : 4536 - 4538
  • [46] Spectral characterization of laser-accelerated protons with CR-39 nuclear track detector
    Seimetz, M.
    Bellido, P.
    Garcia, P.
    Mur, P.
    Iborra, A.
    Soriano, A.
    Hulber, T.
    Garcia-Lopez, J.
    Jimenez-Ramos, M. C.
    Lera, R.
    Ruiz-de la Cruz, A.
    Sanchez, I.
    Zaffino, R.
    Roso, L.
    Benlloch, J. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (02):
  • [47] SENSITIVITY STUDY OF CR-39 PLASTIC TRACK DETECTORS
    HE, YD
    PRICE, PB
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (03): : 491 - 494
  • [48] STUDY ON THE SENSITIVITY OF SOLID-STATE NUCLEAR TRACK DETECTOR (SSNTD) CR-39 FOR ALPHA-PARTICLES REGISTRATION
    GABER, M
    ELKHIER, AAA
    FAHMI, NM
    ISOTOPENPRAXIS, 1991, 27 (07): : 346 - 349
  • [49] Sensitivity study of CR-39 plastic track detectors
    He, Y.D.
    Price, P.B.
    Nuclear Tracks and Radiation Measurements, 1992, 20 (03): : 491 - 494
  • [50] Evaluation of the sensitivity function V for registration of α-particles in PADC CR-39 solid state nuclear track detector material
    Hermsdorf, Dietrich