Application of Molecularly Imprinted Polymer-modified Potentiometric Sensor for Quantitative Determination of Histamine in Serum

被引:3
|
作者
Konishi, Atsuko [1 ]
Takegami, Shigehiko [1 ]
Idosaki, Yoko [1 ]
Kitade, Tatsuya [1 ]
机构
[1] Kyoto Pharmaceut Univ, Dept Analyt Chem, Yamashina Ku, 5 Misasaginakauchi Cho, Kyoto 6078414, Japan
关键词
Potentiometric sensor; molecularly imprinted polymer; histamine; serum; quantitative determination; selectivity; H-4; RECEPTOR;
D O I
10.2116/analsci.20N018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A molecularly imprinted polymer-modified potentiometric histamine (HIS) sensor was prepared and used for quantitative determination of HIS in bovine serum. The calibration curve using the potential responses measured in 1 x 10(-3) mol L-1 phosphate buffer (pH 7.4) showed good linearity in the HIS concentration range of 3 x 10(-4) to 1 x 10(-2) mol L-1 (r = 0.92), with a detection limit of 1.6 x 10(-4) mol L-1. In bovine serum samples, the HIS sensor showed good recovery values of 91 - 104%. Therefore, this HIS sensor successfully determined the HIS concentration in bovine serum samples.
引用
收藏
页码:1561 / 1563
页数:3
相关论文
共 50 条
  • [31] Development of uric acid sensor based on molecularly imprinted polymer-modified hanging mercury drop electrode
    Lakshmi, Dhana
    Sharma, Piyush Sindhu
    Prasad, Bhim Bali
    ELECTROANALYSIS, 2006, 18 (09) : 918 - 927
  • [32] Potentiometric propranolol-selective sensor based on molecularly imprinted polymer
    O. Gurtova
    L. Ye
    F. Chmilenko
    Analytical and Bioanalytical Chemistry, 2013, 405 : 287 - 295
  • [33] Potentiometric propranolol-selective sensor based on molecularly imprinted polymer
    Gurtova, O.
    Ye, L.
    Chmilenko, F.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (01) : 287 - 295
  • [34] Rapid recognition and determination of tryptophan by carbon nanotubes and molecularly imprinted polymer-modified glassy carbon electrode
    Wu, Yiyong
    Deng, Peihong
    Tian, Yaling
    Ding, Ziyu
    Li, Guangli
    Liu, Jun
    Zuberi, Zavuga
    He, Quanguo
    BIOELECTROCHEMISTRY, 2020, 131
  • [35] An electrochemical sensor for the determination of phoxim based on a graphene modified electrode and molecularly imprinted polymer
    Tan, Xuecai
    Wu, Jiawen
    Hu, Qi
    Li, Xiaoyu
    Li, Pengfei
    Yu, Huicheng
    Li, Xiaoyan
    Lei, Fuhou
    ANALYTICAL METHODS, 2015, 7 (11) : 4786 - 4792
  • [36] An optical sensor for the determination of digoxin in serum samples based on a molecularly imprinted polymer membrane
    Paniagua Gonzalez, Gema
    Fernandez Hernando, Pilar
    Durand Alegria, J. S.
    ANALYTICA CHIMICA ACTA, 2009, 638 (02) : 209 - 212
  • [37] Determination of Sodium Benzoate in Liquids Using a Piezoelectric Sensor Modified by a Molecularly Imprinted Polymer
    Zyablov, A. N.
    Vu Hoang Yen
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (12) : 1607 - 1611
  • [38] Determination of Sodium Benzoate in Liquids Using a Piezoelectric Sensor Modified by a Molecularly Imprinted Polymer
    A. N. Zyablov
    Journal of Analytical Chemistry, 2022, 77 : 1607 - 1611
  • [39] Development of a Creatinine Sensor Based on a Molecularly Imprinted Polymer-Modified Sol-Gel Film on Graphite Electrode
    Patel, Amit Kumar
    Sharma, Piyush Sindhu
    Prasad, Bhim Bali
    ELECTROANALYSIS, 2008, 20 (19) : 2102 - 2112
  • [40] Electrochemical determination of progesterone in calf serum samples using a molecularly imprinted polymer sensor
    Laza, Anabel
    Godoy, Ana
    Pereira, Sirley
    Aranda, Pedro R.
    Garcia, Carlos D.
    Raba, Julio
    Bertolino, Franco A.
    MICROCHEMICAL JOURNAL, 2022, 183