A fast and sensitive analytical procedure for monitoring of synthetic pyrethroid pesticides' metabolites in environmental water samples

被引:17
|
作者
Pasupuleti, Raghavendra Rao [1 ]
Tsai, Pei-Chien [1 ]
Ponnusamy, Vinoth Kumar [1 ,2 ]
机构
[1] Kaohsiung Med Univ, Dept Med & Appl Chem, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Res Ctr Environm Med, Kaohsiung, Taiwan
关键词
Vortex-assisted; Salt-induced; Microextraction technique; Liquid chromatography; Tandem mass spectrometer; Pesticides' metabolites; Aqueous samples; LIQUID-LIQUID MICROEXTRACTION; SOLID-PHASE EXTRACTION; HUMAN URINE; CHROMATOGRAPHY; INSECTICIDES; DEGRADATION; DERIVATIZATION; DELTAMETHRIN; CYPERMETHRIN; VEGETABLES;
D O I
10.1016/j.microc.2019.05.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we report a simple, fast, and sensitive analytical procedure for monitoring of synthetic pyrethroid pesticides' (SPPs') metabolites in environmental water samples using a novel vortex-assisted salt-induced liquid liquid microextraction (VA-SI-LLME) method coupled with liquid chromatography/tandem mass spectrometric (LC-MS/MS) analysis. VA-SI-LLME was carried out by taking 4 mL of sample solution followed by the addition of isopropanol and ethyl acetate (0.4 mL, 1:2, v/v) as a binary extraction solvent, and 4 g of ammonium sulfate for phase separation. Then, the mixture solution was vortex for 2 min and centrifuged for 3 min to collect the extractant and inject into LC-MS/MS for analysis. Experimental factors affecting the VA-SI-LLME including extraction solvent, extraction solvent volume, salt type, amount of salt, extraction time, and sample pH were completely optimized. The developed analytical method was validated, and the results exhibited good linearity in the concentration ranges between 0.01-100 ng mL(-1) with the correlation coefficient (r(2)) > 0.992 for the target SPPs' metabolites. Excellent limit of quantification and precision were achieved in the range between 0.01-0.1 ng mL(-1), and 1.55-5.06% (in terms relative standard deviation), respectively. The developed method was employed to determine the target SPPs' metabolites in tap, lake, river water, and influent wastewater samples collected in Kaohsiung city area, Taiwan. The extraction recoveries of spiked samples were satisfactory. Therefore, the presented method can be used as a potential alternative analytical procedure for monitoring of pesticides' metabolites in aqueous samples.
引用
收藏
页码:355 / 363
页数:9
相关论文
共 50 条
  • [21] An easy and fast IC-CL procedure for the monitoring of Cu(II) and Co(II) in environmental samples
    J. A. Murillo Pulgarín
    L. F. García Bermejo
    A. Carrasquero Durán
    [J]. International Journal of Environmental Science and Technology, 2017, 14 : 233 - 240
  • [22] A Green Analytical Procedure for Sensitive and Selective Determination of Antimony in Environmental and Biological Samples by Ligandless Cloud Point Extraction
    Rezaei, Vida
    Samadi-Maybodi, Abdolraouf
    [J]. INTERNATIONAL CONFERENCE ON FUNDAMENTAL AND APPLIED SCIENCES 2012 (ICFAS2012), 2012, 1482 : 234 - 239
  • [23] A NEW HYDRAZONE DERIVATIVE AS A SENSITIVE ANALYTICAL REAGENT FOR THE DETERMINATION OF Co(II) IN FOOD, WATER AND SYNTHETIC SAMPLES
    Reddy, P. Nityananda Kumar
    Reddy, G. Trivikram
    Kumar, Sangita D.
    Reddy, A. V. R.
    Parveen, S. Nazneen
    Reddy, N. C. Gangi
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2016, 7 (01): : 153 - 162
  • [24] A fast and sensitive nucleic acid extraction method for the detection of Cryptosporidium by PCR in environmental water samples
    Dellundé, J
    Pina, S
    Jofre, J
    Lucena, F
    [J]. 2ND WORLD WATER CONGRESS: WATER AND HEALTH-MICROBIOLOGY, MONITORING AND DISINFECTION, 2002, 2 (03): : 95 - 100
  • [25] Determination of Pyrethroid Pesticides in Environmental Samples using Ionic Liquid Dispersive Liquid-Liquid Microextraction
    Wu, Tong
    Liu, Yu
    Yang, Zhonghua
    Gao, Haixiang
    Zhou, Zhiqiang
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (07) : 1327 - 1333
  • [26] Analytical aspects of the gas chromatographic determination of tributyltin and metabolites in environmental samples
    Vella, AJ
    Mintoff, B
    Axiak, V
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2000, 258 (1-2) : 81 - 88
  • [27] ANALYTICAL STUDY ON THE DETERMINATION OF BORON IN ENVIRONMENTAL WATER SAMPLES
    LOPEZ, FJ
    GIMENEZ, E
    HERNANDEZ, F
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (10-11): : 984 - 987
  • [28] A Fast Screening Procedure for Ketamine and Metabolites in Urine Samples with Tandem Mass Spectrometry
    Lin, Huei R.
    Lin, Hsiu L.
    Lee, Shu F.
    Liu, Chiareiy
    Lua, Ahai C.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2010, 34 (03) : 149 - 154
  • [29] Monoclonal antibody-based broad-specificity immunoassay for monitoring organophosphorus pesticides in environmental water samples
    Xu, Zhen-Lin
    Zeng, Dao-Ping
    Yang, Jin-Yi
    Shen, Yu-Dong
    Beier, Ross C.
    Lei, Hong-Tao
    Wang, Hong
    Sun, Yuan-Ming
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2011, 13 (11): : 3040 - 3048
  • [30] OPTIMIZATION OF AN ANALYTICAL PROCEDURE FOR THE DETERMINATION OF TRIAZINE HERBICIDES IN ENVIRONMENTAL-SAMPLES
    PROSEN, H
    ZUPANCICKRALJ, L
    MARSEL, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 704 (01) : 121 - 130