Imaging and computational considerations for image computed permeability: Operating envelope of Digital Rock Physics

被引:65
|
作者
Saxena, Nishank [1 ]
Hows, Amie [1 ]
Hofmann, Ronny [1 ]
Alpak, Faruk O. [1 ]
Freeman, Justin [1 ]
Hunter, Sander [1 ]
Appel, Matthias [1 ]
机构
[1] Shell Int Explorat & Prod, Houston, TX 77079 USA
关键词
Digital rock; Permeability; Petrology; Numerical solutions; REV; LATTICE BOLTZMANN METHOD; REPRESENTATIVE VOLUME ELEMENT; EFFECTIVE ELASTIC PROPERTIES; POROUS-MEDIA; NUMERICAL SIMULATIONS; PORE-MORPHOLOGY; THIN-SECTIONS; 3D PROPERTIES; 2D IMAGES; NM-SCALE;
D O I
10.1016/j.advwatres.2018.04.001
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
This study defines the optimal operating envelope of the Digital Rock technology from the perspective of imaging and numerical simulations of transport properties. Imaging larger volumes of rocks for Digital Rock Physics (DRP) analysis improves the chances of achieving a Representative Elementary Volume (REV) at which flow-based simulations (1) do not vary with change in rock volume, and (2) is insensitive to the choice of boundary conditions. However, this often comes at the expense of image resolution. This trade-off exists due to the finiteness of current state-of-the-art imaging detectors. Imaging and analyzing digital rocks that sample the REV and still sufficiently resolve pore throats is critical to ensure simulation quality and robustness of rock property trends for further analysis. We find that at least 10 voxels are needed to sufficiently resolve pore throats for single phase fluid flow simulations. If this condition is not met, additional analyses and corrections may allow for meaningful comparisons between simulation results and laboratory measurements of permeability, but some cases may fall outside the current technical feasibility of DRP. On the other hand, we find that the ratio of field of view and effective grain size provides a reliable measure of the REV for siliciclastic rocks. If this ratio is greater than 5, the coefficient of variation for single-phase permeability simulations drops below 15%. These imaging considerations are crucial when comparing digitally computed rock flow properties with those measured in the laboratory. We find that the current imaging methods are sufficient to achieve both REV (with respect to numerical boundary conditions) and required image resolution to perform digital core analysis for coarse to fine-grained sandstones.
引用
收藏
页码:127 / 144
页数:18
相关论文
共 32 条
  • [21] A Blind Study of Four Digital Rock Physics Vendor Laboratories on Porosity, Absolute Permeability, and Primary Drainage Capillary Pressure Data on Tight Outcrops
    Chhatre, Shreerang S.
    Sahoo, Hemant
    Leonardi, Sergio
    Vidal, Keili
    Rainey, Jennifer
    Braun, Edward M.
    Patel, Prateek
    PETROPHYSICS, 2018, 59 (01): : 15 - 24
  • [22] Tailoring Diagnostic Physics Performance Evaluation to the Imager Technology in Digital Roentgen Ray Imaging: Assessing Image Quality
    Bercha, I. H.
    MEDICAL PHYSICS, 2020, 47 (06) : E555 - E556
  • [23] Study of the pore space heterogeneity effect on the absolute permeability tensors calculated under different boundary conditions and driving forces using a "Computational Rock Physics" technology
    Zakirov, T. R.
    Khramchenkov, M. G.
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2022, 216
  • [24] Peridynamic Simulation of Heterogeneous Rock Based on Digital Image Processing and Low-Field Nuclear Magnetic Resonance Imaging
    Zhang, Yanan
    Liu, Chuanju
    Deng, Hongwei
    Lin, Yun
    Li, Jielin
    Gao, Feng
    INTERNATIONAL JOURNAL OF GEOMECHANICS, 2022, 22 (06)
  • [25] Image quality determination of a novel digital detector for X-ray imaging and cone -beam computed tomography applications
    Alzahrani, Hanan
    Richards, Sion
    Sedgwick, Iain
    Seller, Paul
    Konstantinidis, Anastasios
    Royle, Gary
    Ricketts, Kate
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 968
  • [26] Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy
    Paul, Jijo
    Jacobi, Volkmar
    Farhang, Mohammad
    Bazrafshan, Babak
    Vogl, Thomas J.
    Mbalisike, Emmanuel C.
    EUROPEAN RADIOLOGY, 2013, 23 (06) : 1582 - 1593
  • [27] Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy
    Jijo Paul
    Volkmar Jacobi
    Mohammad Farhang
    Babak Bazrafshan
    Thomas J. Vogl
    Emmanuel C. Mbalisike
    European Radiology, 2013, 23 : 1582 - 1593
  • [28] Mechanical Anisotropy and Failure Characteristics of Columnar Jointed Rock Masses (CJRM) in Baihetan Hydropower Station: Structural Considerations Based on Digital Image Processing Technology
    Xia, Yingjie
    Zhang, Chuanqing
    Zhou, Hui
    Zhang, Chunsheng
    Hong, Wangbing
    ENERGIES, 2019, 12 (19)
  • [29] Digital rock physics-based studies on effect of pore types on elastic properties of carbonate reservoir Part 1: Imaging processing and elastic modelling
    Zhao, Jianguo
    Pan, Jianguo
    Hu, Yangming
    Li, Jinsong
    Yan, Bohong
    Li, Chuang
    Sun, Langqiu
    Liu, Xinze
    Acta Geophysica Sinica, 2021, 64 (02): : 656 - 669
  • [30] Digital rock physics-based studies on effect of pore types on elastic properties of carbonate reservoir Part 1: Imaging processing and elastic modelling
    Zhao JianGuo
    Pan JianGuo
    Hu YangMing
    Li JinSong
    Yan BoHong
    Li Chuang
    Sun LangQiu
    Liu XinZe
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2021, 64 (02): : 656 - 669