Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System

被引:10
|
作者
Nakamoto, Ryusuke [1 ]
Nakamoto, Yuji [1 ]
Ishimori, Takayoshi [1 ]
Fushimi, Yasutaka [1 ]
Kido, Aki [1 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Grad Sch Med, Kyoto, Japan
关键词
flexible PET scanner; mobile PET; PET/MRI; MRI; SPATIAL REGISTRATION; ACCURACY; LESIONS; CT;
D O I
10.2967/jnumed.117.197665
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The current study tested a newly developed flexible PET (fxPET) scanner prototype. This fxPET system involves dual arc-shaped detectors based on silicon photomultipliers that are designed to fit existing MRI devices, allowing us to obtain fused PET and MR images by sequential PET and MR scanning. This prospective study sought to evaluate the image quality, lesion detection rate, and quantitative values of fxPET in comparison with conventional whole-body (WB) PET and to assess the accuracy of registration. Methods: Seventeen patients with suspected or known malignant tumors were analyzed. Approximately 1 h after intravenous injection of F-18-FDG, WB PET/CT was performed, followed by fxPET and MRI. For reconstruction of fxPET images, MRI-based attenuation correction was applied. The quality of fxPET images was visually assessed, and the number of detected lesions was compared between the 2 imaging methods. SUVmax and maximum average SUV within a 1 cm(3) spheric volume (SUVpeak) of lesions were also compared. In addition, the magnitude of misregistration between fxPET and MR images was evaluated. Results: The image quality of fxPET was acceptable for diagnosis of malignant tumors. There was no significant difference in detectability of malignant lesions between fxPET and WB PET (P > 0.05). However, the fxPET system did not exhibit superior performance to the WB PET system. There were strong positive correlations between the 2 imaging modalities in SUVmax (rho = 0.88) and SUVpeak (rho = 0.81). SUVmax and SUVpeak measured with fxPET were approximately 1.1-fold greater than measured with WB PET. The average misregistration between fxPET and MR images was 5.5 +/- 3.4 mm. Conclusion: Our preliminary data indicate that running an fxPET scanner near an existing MRI system provides visually and quantitatively acceptable fused PET/MR images for diagnosis of malignant lesions.
引用
收藏
页码:846 / 851
页数:6
相关论文
共 50 条
  • [1] Comparison of PET/MR with PET/CT findings in the abdomen using a sequential MR-PET/CT system
    Crook, D. W.
    Kuhn, F. P.
    Samarin, A.
    Mader, C.
    Hany, T.
    Hodler, J.
    von Schulthess, G. K.
    Schmid, D. T.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S157 - S157
  • [2] PET Performance Evaluation of an MR-Compatible PET Insert
    Wu, Yibao
    Catana, Ciprian
    Farrell, Richard
    Dokhale, Purushottam A.
    Shah, Kanai S.
    Qi, Jinyi
    Cherry, Simon R.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 574 - 580
  • [3] Simultaneous PET/MR imaging with a MR-compatible SiPM PET scanner
    Yoon, Hyun Suk
    Ko, Guen Bae
    Kwon, Sun Il
    Lee, Chan Mi
    Ito, Mikiko
    Song, In Chan
    Lee, Dong Soo
    Hong, Seong Jong
    Lee, Jae Sung
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [4] MR-compatible blood sampler for PET
    Breuer, J.
    Grazioso, R.
    Corbeil, J.
    Zhang, N.
    Schmand, M.
    Wienhard, K.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3426 - +
  • [5] Gamma shielding materials for MR-compatible PET
    Strul, D
    Cash, D
    Keevil, SF
    Halsted, P
    Williams, SCR
    Marsden, PK
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (01) : 60 - 69
  • [6] Evaluation of an MR-compatible blood sampler for PET
    Breuer, J.
    Grazioso, R.
    Zhang, N.
    Schmand, M.
    Wienhard, K.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (19): : 5883 - 5893
  • [7] Simultaneous acquisition of multislice PET and MR images: Initial results with a MR-compatible PET scanner
    Catana, Ciprian
    Wu, Yibao
    Judenhofer, Martin S.
    Qi, Jinyi
    Pichler, Berrid J.
    Cherry, Simon R.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (12) : 1968 - 1976
  • [8] Comparison of performance and workflow of a sequential PET/MR and commercial PET/CT systems
    Nagy, Kalman
    Toth, Miklos
    Haggkvist, Jenny
    Major, Peter
    Nemeth, Gabor
    Domokos, Mathe
    Gulyas, Balazs
    Halldin, Christer
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [9] A multi-slice dual layer MR-compatible animal PET system: K-PET I
    Yamamoto, S.
    Mashino, H.
    Takamatsu, S.
    Matsumoto, K.
    Senda, M.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1708 - +
  • [10] A Multi-Slice Dual Layer MR-Compatible Animal PET System
    Yamamoto, S.
    Hatazawa, J.
    Imaizumi, M.
    Shimosegawa, E.
    Aoki, M.
    Sugiyama, E.
    Kawakami, M.
    Takamatsu, S.
    Minato, K.
    Matsumoto, K.
    Senda, M.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (05) : 2706 - 2713