Diagnostic office hysteroscopy with the Storz TrophyScope® versus Cooper surgical Endosee®

被引:1
|
作者
Leon, Mateo G. [1 ]
Andrew Nguyen [1 ]
Alex Nguyen [1 ]
Dinh, Tri A. [1 ]
Destephano, Christopher C. [1 ]
机构
[1] Mayo Clin, Dept Med & Surg Gynecol, 4500 San Pablo Rd 32224, Jacksonville, FL 32224 USA
来源
MINERVA GINECOLOGICA | 2020年 / 72卷 / 05期
关键词
Hysteroscopy; Pain; Equipment and supplies; RANDOMIZED CONTROLLED-TRIAL; OPERATIVE HYSTEROSCOPY; PATIENT SATISFACTION; OUTPATIENT; ACCURACY; HYPERPLASIA; GYNECOLOGY; COST; PAIN;
D O I
10.23736/S0026-4784.20.04568-2
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
BACKGROUND: Office hysteroscopy (OH) is becoming increasingly popular. Our objective was to determine the use patterns, reported pain scores, and success rates of OH with the 2.9 mm Storz TrophyScope (R) and handheld portable Cooper surgical Endosee (R) device in a clinic without previous office hysteroscopy experience. METHODS: A prospective cohort study of a hysteroscopy quality improvement database was conducted in a tertiary care center gynecology clinic. Patients undergoing OH with either the Storz TrophyScope (R) or Cooper Surgical Endosee (R) device were included. RESULTS: Of the 171 office hysteroscopies, 77 utilized the TrophyScopee, with 8 (10%) being inadequate, while 94 utilized Endosee (R), with 13 (14%) being inadequate (P=0.50). Of the 13 inadequate Endosee (R) hysteroscopies, 4 (31%) were due to visualization, 4 (31%) to patient intolerance, 3 (23%) to cervical stenosis, and 2 (15%) to a combination of these factors. Of the 8 inadequate TrophyScope (R) hysteroscopies, 7 (87%) were due to patient intolerance and 1 (13%) to cervical stenosis. Of the 150 adequate office procedures performed, 52 cases underwent subsequent procedures in the operating room (OR). Of these, 26 (84%) of 31 Endosee (R) cases and 18 (86%) of 21 TrophyScope (R) cases were in agreement with OR procedure findings. A subgroup analysis comparing mean pain levels did not significantly differ between the two hysteroscopes. CONCLUSIONS: There was no difference in accuracy with OR pathologic diagnoses, adequacy of procedure, and reported pain scores when comparing the TrophyScope (R) and Endosee (R) in this prospective cohort. Larger studies are needed to confirm the sensitivity, and specificity for these newer, disposable office hysteroscopic devices.
引用
收藏
页码:310 / 315
页数:6
相关论文
共 50 条
  • [31] Frequency distribution of pregnancy occurrence in infertile women after diagnostic-surgical hysteroscopy
    Nejad, Ensieh Shahrokh Tehrani
    Naderi, Tayebeh
    Irani, Shohreh
    Nekoo, Elham Azimi
    IRANIAN JOURNAL OF REPRODUCTIVE MEDICINE, 2007, 5 (03) : 99 - 102
  • [32] Prospective multicentre randomized controlled trial to evaluate factors influencing the success rate of office diagnostic hysteroscopy
    Campo, R
    Molinas, CR
    Rombauts, L
    Mestdagh, G
    Lauwers, M
    Braekmans, P
    Brosens, I
    Van Belle, Y
    Gordts, S
    HUMAN REPRODUCTION, 2005, 20 (01) : 258 - 263
  • [33] Carbon dioxide in office diagnostic hysteroscopy: An open question. A multicenter randomized trial on 1982 procedures
    Tagliaferri, Valeria
    Ricciardi, Luigi
    Ricciardi, Raffaele
    Pinto, Lauro R.
    Lanzone, Antonio
    Scambia, Giovanni
    Guido, Maurizio
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2019, 235 : 97 - 101
  • [34] Operative Hysteroscopy in an Office-Based Surgical Setting: Review of Patient Safety and Satisfaction in 414 Cases
    Wortman, Morris
    Daggett, Amy
    Ball, Courtney
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2013, 20 (01) : 56 - 63
  • [35] ON DIAGNOSTIC ERRORS IN ACUTE APPENDICITIS AT THE ADMITTING OFFICE OF THE SURGICAL HOSPITAL
    LEBEDEV, LV
    PUDYAKOV, SM
    VESTNIK KHIRURGII IMENI I I GREKOVA, 1989, 142 (05): : 123 - 126
  • [36] Misoprostol versus uterine straightening by bladder distension for pain relief in postmenopausal patients undergoing diagnostic office hysteroscopy: a randomised controlled non-inferiority trial
    Fouda, Usama M.
    Elshaer, Hesham S.
    Elsetohy, Khaled A.
    Youssef, Mohamed A.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2016, 203 : 326 - 330
  • [37] Three-dimensional ultrasound versus office hysteroscopy in assessment of pain and bleeding with intrauterine contraceptive device
    Aboulghar, Mona
    Hegazy, Mohamed
    Saber, Waleed
    Hamed, Alaa
    El Sheikhah, Ahmed
    MIDDLE EAST FERTILITY SOCIETY JOURNAL, 2011, 16 (02) : 121 - 124
  • [38] Treatment of organic uterine bleeding by hysteroscopy versus conventional surgical techniques, a comparative study
    Herman, P
    Gaspard, U
    4TH CONGRESS OF THE EUROPEAN SOCIETY FOR GYNAECOLOGICAL ENDOSCOPY: THE UTERUS THROUGHOUT THE WOMAN'S LIFE, 1996, : 165 - 169
  • [39] SALINE ULTRASOUND VERSUS OFFICE HYSTEROSCOPY FOR UTERINE CAVITY EVALUATION PRIOR TO IVF: A RANDOMIZED CONTROLLED TRIAL.
    Moustafa, Sarah M.
    Silverstein, Gina
    Young, Steven L.
    Goodman, Linnea R.
    FERTILITY AND STERILITY, 2020, 114 (03) : E246 - E246
  • [40] 3D Ultrasonography Versus Diagnostic Hysteroscopy for Endometrial Evaluation of Abnormal Uterine Bleeding
    Mat, Corina
    Panaitescu, Anca
    Peltecu, Gheorghe
    Gica, Nicolae
    PROCEEDINGS OF SOGR 2018: THE 17TH NATIONAL CONGRESS OF THE ROMANIAN SOCIETY OF OBSTETRICS AND GYNECOLOGY & FIRST ADVANCED COLPOSCOPY COURSE, 2019, : 424 - 428