Method to remove the effect of ambient temperature on radiometric calibration

被引:26
|
作者
Chang Songtao [1 ,2 ]
Zhang Yaoyu [1 ]
Sun Zhiyuan [1 ]
Li Min [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100039, Peoples R China
关键词
NONUNIFORMITY CORRECTION; RADIATION;
D O I
10.1364/AO.53.006274
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
High precision radiometric calibration is essential for infrared imaging systems, especially in scientific applications where an accurate quantitative analysis is required. Nevertheless, calibration and radiometry are usually not simultaneously performed. Hence the discrepancy of ambient temperature between calibration and actual measurement can generate significant measurement errors unless the calibration results have been properly corrected. To overcome the restriction, we studied the effect of ambient temperature on radiometric calibration, then derived the relationship between calibration results and ambient temperature considering the integration time. A novel method compensating for the impact of ambient temperature on the calibration of a cooled infrared system is proposed. Several experiments are performed, and the results indicate that the proposed method can not only ensure the accuracy of calibration but achieve calibration results under any ambient temperature and arbitrary integration time. (C) 2014 Optical Society of America
引用
收藏
页码:6274 / 6279
页数:6
相关论文
共 50 条
  • [11] Simplified method for radiometric calibration of an array camera
    Cano-Garcia, Angel
    Lazaro, Jose Luis
    Fernandez, Pedro R.
    2007 IEEE INTERNATIONAL SYMPOSIUM ON INTELLIGENT SIGNAL PROCESSING, CONFERENCE PROCEEDINGS BOOK, 2007, : 401 - +
  • [12] Automatic and robust method for relative radiometric calibration
    Wen, GJ
    Li, DR
    Wang, RS
    OPTICAL REMOTE SENSING OF THE ATMOSPHERE AND CLOUDS III, 2003, 4891 : 326 - 334
  • [13] Sensitivity of AIRS and IASI radiometric calibration to scene temperature
    Elliott, Denis A.
    Aumann, Hartmut H.
    EARTH OBSERVING SYSTEMS XVI, 2011, 8153
  • [14] Effect of ambient temperature and attachment method on surface temperature measurements
    Psikuta, Agnes
    Niedermann, Reto
    Rossi, Rene M.
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2014, 58 (05) : 877 - 885
  • [15] Effect of ambient temperature and attachment method on surface temperature measurements
    Agnes Psikuta
    Reto Niedermann
    René M. Rossi
    International Journal of Biometeorology, 2014, 58 : 877 - 885
  • [16] Laboratory Calibration and Temperature Research of Spectral Radiometric Instruments
    Li Ling
    Dai Cai-hong
    Wu Zhi-feng
    Wang Yan-fei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (06) : 1965 - 1969
  • [17] A novel nonintrusive method to resolve the thermal dome effect of pyranometers: Radiometric calibration and implications
    Ji, Q.
    Tsay, S. -C.
    Lau, K. M.
    Hansell, R. A.
    Butler, J. J.
    Cooper, J. W.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2011, 116
  • [18] DEVELOPMENT OF A PORTABLE AMBIENT-TEMPERATURE RADIOMETRIC ASSAYING INSTRUMENT
    LAVIETES, AD
    MCQUAID, JH
    RUHTER, WD
    PAULUS, TJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 634 - 638
  • [19] Polarization radiometric calibration method for multichannel polarization camera
    Li, Yi
    Zhang, Haiyang
    Liu, Wei
    Yan, Changxiang
    OPTIK, 2018, 172 : 980 - 987
  • [20] Temperature Standard for Radiometric Calibration of Earth-observation Sensor
    Yamaguchi, Yu
    Yamada, Yoshiro
    2017 56TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2017, : 424 - 426