Method to remove the effect of ambient temperature on radiometric calibration

被引:26
|
作者
Chang Songtao [1 ,2 ]
Zhang Yaoyu [1 ]
Sun Zhiyuan [1 ]
Li Min [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100039, Peoples R China
关键词
NONUNIFORMITY CORRECTION; RADIATION;
D O I
10.1364/AO.53.006274
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
High precision radiometric calibration is essential for infrared imaging systems, especially in scientific applications where an accurate quantitative analysis is required. Nevertheless, calibration and radiometry are usually not simultaneously performed. Hence the discrepancy of ambient temperature between calibration and actual measurement can generate significant measurement errors unless the calibration results have been properly corrected. To overcome the restriction, we studied the effect of ambient temperature on radiometric calibration, then derived the relationship between calibration results and ambient temperature considering the integration time. A novel method compensating for the impact of ambient temperature on the calibration of a cooled infrared system is proposed. Several experiments are performed, and the results indicate that the proposed method can not only ensure the accuracy of calibration but achieve calibration results under any ambient temperature and arbitrary integration time. (C) 2014 Optical Society of America
引用
收藏
页码:6274 / 6279
页数:6
相关论文
共 50 条
  • [1] A REBPNet-based IR radiometric calibration method considering ambient temperature change
    Li, Ting
    Lai, Xuefeng
    Liao, Sheng
    Zhao, Xulong
    Xia, Yucheng
    Zhou, Jinmei
    INFRARED PHYSICS & TECHNOLOGY, 2025, 145
  • [2] High emissivity blackbody for radiometric calibration near ambient temperature
    Té, Y
    Jeseck, P
    Camy-Peyret, C
    Payan, S
    Briaudeau, S
    Fanjeaux, M
    METROLOGIA, 2003, 40 (02) : 24 - 30
  • [3] Method to Remove the Effect of Atmosphere and Ambient Radiation on Colorimetric Temperature Measurement
    Lv, You
    He, Xin
    Wei, Zhong-Hui
    Yuan, Hang-Fei
    IAEDS15: INTERNATIONAL CONFERENCE IN APPLIED ENGINEERING AND MANAGEMENT, 2015, 46 : 937 - 942
  • [4] A calibration method for radiometric and wavelength calibration of a spectrometer
    Granger, EM
    COLOR IMAGING: DEVICE-INDEPENDENT COLOR, COLOR HARDCOPY, AND GRAPHIC ARTS IV, 1998, 3648 : 237 - 241
  • [5] A method to retrieve blackbody temperature errors in the two points radiometric calibration
    Te, Yao
    Jeseck, Pascal
    Pepin, Isabelle
    Camy-Peyret, Claude
    INFRARED PHYSICS & TECHNOLOGY, 2009, 52 (05) : 187 - 192
  • [6] Effect of Ambient Temperature on Calibration of Cooled Thermal Camera
    Sharma, A. K.
    Sharma, S. K.
    Vasistha, P.
    Mangalhara, J. P.
    DEFENCE SCIENCE JOURNAL, 2017, 67 (02) : 173 - 176
  • [7] RADIOMETRIC ANTENNA GAIN CALIBRATION METHOD
    ULICH, BL
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1977, 25 (02) : 218 - 223
  • [8] PRINCIPLES OF CALIBRATION FOR RADIOMETRIC TEMPERATURE-MEASUREMENTS
    DEWITT, DP
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 520 : 2 - 10
  • [9] Influence of ambient temperature on the radiation of IR reference sources: effect on the calibration of IR sensors and method of compensation
    Barrat, Catherine
    Audouin, Alex
    Auvray, Gauthier
    ELECTRO-OPTICAL AND INFRARED SYSTEMS: TECHNOLOGY AND APPLICATIONS XV, 2018, 10795
  • [10] Studies on Calibration of IR Radiometer by Radiometric Method
    Kaur, S.
    Pandey, S. M.
    Bhusare, S. E.
    2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL INSTRUMENTATION AND CONTROL (ICIC), 2015, : 111 - 114