Calibration of AC Vector Magnetometer Based on Ellipsoid Fitting

被引:16
|
作者
Yu, XiangQian [1 ]
Xiao, ChiJie [2 ]
Liu, Si [3 ]
Zong, QiuGang [1 ]
Qu, YaNan [4 ]
Chen, HongFei [1 ]
Zou, Hong [1 ]
Shi, WeiHong [1 ]
Wang, YongFu [1 ]
Chen, Ao [1 ]
Song, SiYu [1 ]
Gao, Shuang [4 ]
Shao, SiPei [4 ]
机构
[1] Peking Univ, Sch Earth & Space Sci, Beijing 100871, Peoples R China
[2] Peking Univ, Sch Phys, Beijing 100871, Peoples R China
[3] Changsha Univ Sci & Technol, Sch Phys & Elect Sci, Changsha 410114, Peoples R China
[4] Inst Shandong Aerosp Technol, Yantai 264003, Peoples R China
关键词
AC vector magnetometer; angular misalignments and offset errors; ellipsoid fitting; scaling factors;
D O I
10.1109/TIM.2020.3014980
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
AC vector magnetometers have recently become increasingly widespread. The calibration of ac vector magnetometers before use is critical. Based on traditional ellipsoid fitting, which is suitable for calibrating dc vector magnetometers, a method suitable for calibrating ac vector magnetometers is presented. Simulation analysis and experimental verification demonstrate that this method is effective in calibrating ac vector magnetometers, including scaling factors, angular misalignments, and offset errors.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Improved Ellipsoid Fitting Method Based on Tensor Mix Source Separation for Correcting the Three-Component Magnetometer
    Li, Ruoyu
    Miao, Hongsong
    Hao, Yi
    Sui, Yangyi
    IEEE SENSORS JOURNAL, 2025, 25 (04) : 6226 - 6233
  • [22] Particle Swarm Optimization With Rotation Axis Fitting for Magnetometer Calibration
    Riwanto, Bagus Adiwiluhung
    Tikka, Tuomas
    Kestila, Antti
    Praks, Jaan
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2017, 53 (02) : 1009 - 1022
  • [23] Performance comparison of accelerometer calibration algorithms based on 3D-ellipsoid fitting methods
    Gietzelt, Matthias
    Wolf, Klaus-Hendrik
    Marschollek, Michael
    Haux, Reinhold
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2013, 111 (01) : 62 - 71
  • [24] Calibration of MEMS Accelerometer Using Kaiser Filter and the Ellipsoid Fitting Method
    Cui, Shiwei
    Cui, Lingguo
    Du, Yidong
    Chai, Senchun
    Zhang, Baihai
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 4679 - 4684
  • [25] Influence of Periodical Interference on Calibration Process of Vector Magnetometer
    Kliment, Tomas
    Krchnak, Martin
    Mizenkova, Zaneta
    Lipovsky, Pavol
    2016 NEW TRENDS IN SIGNAL PROCESSING (NTSP), 2016, : 43 - 46
  • [26] Analysis of Instrumental Errors Influence on the Vector Magnetometer Calibration
    Morozov, Yury, V
    Murasev, Aleksey A.
    Spektor, Aleksandr A.
    2020 1ST INTERNATIONAL CONFERENCE PROBLEMS OF INFORMATICS, ELECTRONICS, AND RADIO ENGINEERING (PIERE), 2020, : 44 - 48
  • [27] Automatic calibration of the 3D Vector Magnetometer
    Long, Li
    Zhang, He
    MANUFACTURING ENGINEERING AND AUTOMATION II, PTS 1-3, 2012, 591-593 : 1256 - +
  • [28] PROCEDURE FOR ACCURATE CALIBRATION OF ORIENTATION OF 3 SENSORS IN A VECTOR MAGNETOMETER
    MCPHERRON, RL
    SNARE, RC
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1978, 16 (02): : 134 - 137
  • [29] Improvement of Formula and Uncertainty of the Reference Magnetic Field for AC Magnetometer Calibration
    Ishii, Masanori
    Ketzler, Rainer
    Albrecht, Martin
    Kurokawa, Satoru
    Shimada, Yozo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (06) : 1443 - 1449
  • [30] Automatic Determination of Validity of Input Data Used in Ellipsoid Fitting MARG Calibration Algorithms
    Olivares, Alberto
    Ruiz-Garcia, Gonzalo
    Olivares, Gonzalo
    Manuel Gorriz, Juan
    Ramirez, Javier
    SENSORS, 2013, 13 (09) : 11797 - 11817