Calibration of AC Vector Magnetometer Based on Ellipsoid Fitting

被引:16
|
作者
Yu, XiangQian [1 ]
Xiao, ChiJie [2 ]
Liu, Si [3 ]
Zong, QiuGang [1 ]
Qu, YaNan [4 ]
Chen, HongFei [1 ]
Zou, Hong [1 ]
Shi, WeiHong [1 ]
Wang, YongFu [1 ]
Chen, Ao [1 ]
Song, SiYu [1 ]
Gao, Shuang [4 ]
Shao, SiPei [4 ]
机构
[1] Peking Univ, Sch Earth & Space Sci, Beijing 100871, Peoples R China
[2] Peking Univ, Sch Phys, Beijing 100871, Peoples R China
[3] Changsha Univ Sci & Technol, Sch Phys & Elect Sci, Changsha 410114, Peoples R China
[4] Inst Shandong Aerosp Technol, Yantai 264003, Peoples R China
关键词
AC vector magnetometer; angular misalignments and offset errors; ellipsoid fitting; scaling factors;
D O I
10.1109/TIM.2020.3014980
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
AC vector magnetometers have recently become increasingly widespread. The calibration of ac vector magnetometers before use is critical. Based on traditional ellipsoid fitting, which is suitable for calibrating dc vector magnetometers, a method suitable for calibrating ac vector magnetometers is presented. Simulation analysis and experimental verification demonstrate that this method is effective in calibrating ac vector magnetometers, including scaling factors, angular misalignments, and offset errors.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Calibration of triaxial magnetometer with ellipsoid fitting method
    Chi, Cheng
    Lv, Jun-Wei
    Wang, Dan
    4TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2019, 237
  • [2] Simplified Ellipsoid Fitting-Based Magnetometer Calibration for Pedestrian Dead Reckoning
    Liu, Donghui
    Pei, Ling
    Qian, Jiuchao
    Wang, Lin
    Liu, Chengxuan
    Liu, Peilin
    Yu, Wenxian
    CHINA SATELLITE NAVIGATION CONFERENCE (CSNC) 2016 PROCEEDINGS, VOL II, 2016, 389 : 473 - 486
  • [3] Effects of Outlier Elimination in Magnetometer Calibration Data on the Performance of Ellipsoid Fitting-based Calibration
    Kim, Ji Hoon
    Lee, Chang June
    Lee, Jung Keun
    Journal of Institute of Control, Robotics and Systems, 2024, 30 (12) : 1373 - 1378
  • [4] Magnetometer calibration algorithm based on ellipsoid constraint
    董明杰
    Chou Wusheng
    Fang Bin
    High Technology Letters, 2015, 21 (04) : 407 - 413
  • [5] Magnetometer calibration algorithm based on ellipsoid constraint
    Dong, Mingjie
    Chou, Wusheng
    Fang, Bin
    High Technology Letters, 2015, 21 (04) : 407 - 413
  • [6] Real-Time 3D Magnetometer Calibration for Embedded Systems Based on Ellipsoid Fitting
    Tedesco, Salvatore
    Torres-Sanchez, Javier
    O'Flynn, Brendan
    2018 12TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2018, : 424 - 429
  • [7] Ellipsoid Fitting Calibration Method Based on Genetic Algorithm
    Chen Genpu
    Lei Xusheng
    Geng Yue
    PROCEEDINGS OF THE 2ND INTERNATIONAL FORUM ON MANAGEMENT, EDUCATION AND INFORMATION TECHNOLOGY APPLICATION (IFMEITA 2017), 2017, 130 : 515 - 524
  • [8] Validation of the magnetometer calibration algorithms based on geometric fitting
    Pham, Duc An
    Toan, Nguyen Duc
    Pham, Trung Nghia
    MODERN PHYSICS LETTERS B, 2023, 37 (16):
  • [9] Calibration of a Vector Magnetometer Based on Minimum Residual
    Zlygostev, I. N.
    Morozov, Yu. V.
    Murasev, A. A.
    Spektor, A. A.
    OPTOELECTRONICS INSTRUMENTATION AND DATA PROCESSING, 2024, 60 (06) : 803 - 809
  • [10] Triaxial gyroscope fast calibration method based on ellipsoid fitting
    Long, Dafeng
    Liu, Jun
    Zhang, Xiaoming
    Li, Jie
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2013, 34 (06): : 1299 - 1305